Sign In
Upload
Manuals
Brands
Southwest Microwave Manuals
Measuring Instruments
INTREPID MicroTrack II
Southwest Microwave INTREPID MicroTrack II Manuals
Manuals and User Guides for Southwest Microwave INTREPID MicroTrack II. We have
1
Southwest Microwave INTREPID MicroTrack II manual available for free PDF download: Installation And Operation Manual
Southwest Microwave INTREPID MicroTrack II Installation And Operation Manual (70 pages)
A BURIED TERRAIN-FOLLOWING OUTDOOR PERIMETER INTRUSION DETECTION SYSTEM
Brand:
Southwest Microwave
| Category:
Measuring Instruments
| Size: 1 MB
Table of Contents
Table of Contents
7
1 Introduction
9
Theory of Operation
9
Target Processing
11
Features and Benefits
13
2 Microtrack™ II Detection Characteristics
15
Detection Requirements and Expectations
15
Microtrack II Typical Detection Pattern
15
Detection Field
15
Detection Pattern Width
17
Detection Pattern Height
17
Sensor Cable Maximum Length
18
3 Microtrack II System Components
21
Hardware Components
21
Microtrack Processor II (MTP II)
21
Microtrack Sensor Cable Assembly
22
Microtrack End of Line Termination Kit (MTT)
22
Microtrack in Line Termination Kit (MTI)
23
Microtrack Enclosure - Metallic (MTE-ME)
23
Microtrack Enclosure - Stainless Steel (MTE-SS)
23
Microtrack Splice Kit (MTS)
24
Microtrack - Sensor Cable
24
Microtrack Lead-In Cable Assembly
24
JB70 Lightning/Surge Protection Module
24
Power Supplies
25
Control Modules
25
Relay Control Module II (RCM II)
25
Control Module II (CM II)
25
Craphic Control Module II (GCM II)
25
Perimeter Security Manager
26
INTREPID Polling Protocol II (IPP II)
26
Software Components
26
Universal Installation / Service Tool
26
4 Site Planning / System Configuration
27
Basic Microtrack II Configuration Parameters
27
MTP II System Architecture Example
27
Site Survey
31
5 System Design
33
Burial Medium
33
Site Environment and Occurrence of Frost
33
Animals and the Detection Field
34
Accomodating Grass, Trees and Shrubs
34
Uneven Terrain
35
Rain, Standing Water and Run-Off
36
Positioning Microtrack II Components on the Perimeter
37
Selecting the Optimum Sensor Cable Spacing
39
Double Fences, Concertina and Razor Tape
41
Cable Spacing Near Buildings
42
6 Installation of the Sensor Cable
43
Burying Sensor Cables in Soil
43
Burying Sensor Cables in Different Mediums
46
Bypassing Large Non-Metallic Pipes and Culverts
47
Buried Electrical Cable, Conduits and Wires
48
Overhead Electrical Cable and Conduits
48
Arranging Lead-In and Sensor Cables for Detection Field Startup
48
Locating an MTP Near a Fence Corner
50
Making Turns with Sensor Cable
51
Terminating the Sensor Cable Near Buildings
52
Terminating the Sensor Cable
53
Splicing the Sensor Cable
58
7 Installing the Microtrack™ Processor (MTP)
61
Positioning the MTP II
61
Installing the Microtrack II Enclosure (MTE)
61
Grounding the MTP II
62
Power and Data Connections
62
Connecting the PC Using RS232
63
Connecting the Controller Using RS422
63
Connecting Sensor Cables to the MTP II
65
8 Alarm Reporting
67
Relay Outputs
67
Serial Communications - Polling Protocol II
67
9 Maintenance
69
Advertisement
Advertisement
Related Products
Southwest Microwave INTREPID
Southwest Microwave Categories
Transceiver
Security Sensors
Accessories
Measuring Instruments
Test Equipment
More Southwest Microwave Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL