Sign In
Upload
Manuals
Brands
Sonel Manuals
Measuring Instruments
MPI-540-PV
Sonel MPI-540-PV Manuals
Manuals and User Guides for Sonel MPI-540-PV. We have
2
Sonel MPI-540-PV manuals available for free PDF download: User Manual, Brief User Manual
Sonel MPI-540-PV User Manual (212 pages)
METER FOR ELECTRICAL INSTALLATION PARAMETERS
Brand:
Sonel
| Category:
Measuring Instruments
| Size: 21 MB
Table of Contents
Table of Contents
5
Safety
9
Main Menu
10
Meter Settings
11
Setting Date and Time
12
Automatic Shutdown
13
Display Parameters
14
Settings of Measurements
15
Sub-Menu Measurements
15
Sub-Menu Edit Fuses
16
Adding Fuse Characteristics
16
Adding Fuses
21
Sub-Menu PV Modules
23
Communication
24
USB Communication
24
Connection to a Wi-Fi Network
24
Connection with an Irradiance Meter
24
E-Mail Settings
25
Software Update
25
Update Via USB
25
Update Via Wi-Fi
26
Regional Settings
26
Meter Information
27
Measurements
28
Diagnostics Performed by the Meter - Limits
29
Measurement of Alternating Voltage and Frequency
29
Checking the Correctness of PE (Protective Earth) Connections
30
Fault Loop Parameters
31
Settings of Measurements
31
Fault Loop Parameters in the L-N and L-L Circuits
33
Fault Loop Parameters in the L-PE Circuit
36
Fault Loop Impedance in L-PE Circuit Protected with a Residual Current Device (RCD)
39
Prospective Short-Circuit Current
42
Measurement of Fault Loop Impedance in IT Networks
43
Voltage Drop
44
Resistance-To-Earth
46
Settings of Measurements
46
Earth Resistance Measurement with 3-Pole Method (R 3P)
48
Earth Resistance Measurement with 4-Wire Method (R 4P)
52
Earth Resistance Measurement with 3-Pole Method with Additional Clamp
56
E 3P+C)
56
Soil Resistivity
63
Settings of Measurements
63
Main Elements of the Screen
64
Soil Resistivity Measurements (Ρ)
65
RCD Parameters
69
Settings of Measurements
69
RCD Tripping Current
72
RCD Tripping Time
75
Measurements in IT Networks
78
Automatic Measurements of RCD Parameters
79
Setting Automatic Measurements of RCD Parameters
79
Automatic Measurement of Rcds
80
Insulation Resistance
84
Settings of Measurements
84
Measurement Using Probes
88
Measurements Using UNI-Schuko Adapter (WS-03 and WS-04)
90
Measurements Using Autoiso-1000C
93
Low-Voltage Resistance Measurement
97
Resistance Measurement
97
Measurement of Resistance of Protective Conductors and Equipotential Bonding with ±200 Ma Current
100
Phase Sequence
104
Motor Rotation Direction
105
Illuminance
107
Resistance-To-Earth (PV)
108
Insulation Resistance (PV)
109
Continuity of Connections (PV)
109
Open Circuit DC Voltage UOC
110
Short Circuit DC Current ISC
111
Test of the Inverter Panel Η, P, I
112
Measurement Configuration
113
Live Mode
116
Resetting C-PV Clamp
117
Irradiance and Temperature
117
Auto Measurements
118
Proceeding Auto Measurements
118
Creating Measurement Procedures
120
Recorder
122
Functional Description
122
Main Elements of the Screen
124
Top Bar
125
Title Bar
125
Main Window
126
Information Bar on the Parameters of the Current Network
126
Help
126
Connecting the Measuring System
127
Measuring Arrangements
127
Verifying the Connection
130
Recording Configuration
131
Configuration Using the Meter
131
Recording Configuration
132
Analyzer Settings
134
Hardware Settings - Clamps (Manner of Connecting)
134
Settings - Regional Settings
135
Managers - File Manager
137
Data Viewing
137
Data Preview
138
LIVE Mode of the Network
139
Transient Waveforms of Current and Voltages (Waveforms)
139
Timeplot of Effective Values
141
Live" Mode - Tabular View
142
Vector Diagram of Fundamental Components (Phasor)
144
Harmonics Graph/Table
145
Switching the Recording On/Off
147
Approximate Recording Times
147
Recording Guidelines
148
Recording Analysis
148
Recording Timeplot
151
Functional Description
151
Selecting Parameters for the Timeplot
153
Creating and Managing a Timeplot
154
Harmonics Waveform Graph
156
Energy Costs Calculator
158
Functional Description
158
Settings of the Energy Cost Calculator
159
Energy Loss Calculator
161
Functional Description
161
Configuration of the Loss Calculator
162
Inverter Efficiency
163
Memory of the Meter
164
Memory of Measurements
164
Memory Settings
164
Structure of the Memory
165
Fundamentals of Navigating the Memory Menu
166
Adding a New Measurements Tree
168
Entering the Measurement Result
173
Viewing Saved Measurements
174
Sharing Recorded Measurements
176
Searching the Meter Memory
177
Recorder Memory
178
Microsd Memory Card
178
USB External Memory (Flash Drive)
178
Compatibility with Sonel Analysis Software
178
PC Connection and Data Transmission
178
Power Supply
180
Monitoring of the Battery Charge Status
180
Replacing Rechargeable Batteries
180
Charging the Rechargeable Batteries
181
General Rules for Using Li-Ion Rechargeable Batteries
182
Cleaning and Maintenance
183
Storage
183
Dismantling and Utilisation
183
Technical Data
184
Basic Data
184
Measurement of Alternating Voltages (True RMS)
184
Frequency Measurement
184
L-Pe , Z L-N , Z L-L
184
Measurement of Fault Loop Impedance Z
185
L-PE[RCD] (Without Triggering of RCD)
185
Measurement of Fault Loop Impedance Z
186
Measurement of Parameters of RCD
186
Measurement of Resistance-To-Earth R
189
Low-Voltage Measurement of Continuity of Circuit and Resistance
190
Measurement of Insulation Resistance
191
Light Measurements
192
Phase Sequence
193
Motor Rotation
193
Measurement of Open Circuit DC Voltage UOC
193
Measurement Od Short Circuit DC Current ISC
193
Recorder Data
193
Inputs
193
Sampling and RTC
194
Voltage Measurement
194
Measurement of Current (True RMS)
195
Frequency Measurement
195
Measuring Harmonics
196
Unbalance
196
Power and Energy Measurement
196
Estimated Measurement Uncertainty Values for Power and Energy
197
Other Technical Data
198
Additional Data
199
Additional Uncertainties According to IEC 61557-2
199
Iso
199
Additional Uncertainties According to IEC 61557-3 (Z)
199
Additional Uncertainties According to IEC 61557-4 (R ±200 Ma)
199
Additional Uncertainties of Earth Resistance Measurement
199
Additional Uncertainties According to IEC 61557-6 (RCD)
200
List of Reference Standards
200
Accessories
201
Standard Accessories
201
Optional Accessories
202
C-PV Clamp
208
Positions of the Meter's Cover
209
Manufacturer
209
Laboratory Services
210
Advertisement
Sonel MPI-540-PV Brief User Manual (76 pages)
Brand:
Sonel
| Category:
Measuring Instruments
| Size: 6 MB
Table of Contents
Table of Contents
4
Security
7
Main Menu
8
Meter Settings
9
Measurement Settings
9
Sub-Menu Measurements
9
Sub-Menu PV Modules
10
Communication
12
USB Communication
12
Connection with an Irradiance Meter
12
Regional Settings
12
Measurements
13
Checking the Correctness of PE (Protective Earth) Connections
14
Fault Loop Parameters
15
Fault Loop Parameters in the L-N and L-L Circuits
15
Fault Loop Parameters in the L-PE Circuit
15
Fault Loop Impedance in L-PE Circuit Protected with a Residual Current Device (RCD)
16
Measurement of Fault Loop Impedance in IT Networks
17
Voltage Drop
18
Resistance-To-Earth
19
Earth Resistance Measurement with 3-Pole Method (R 3P)
19
Earth Resistance Measurement with 4-Wire Method (R 4P)
20
Earth Resistance Measurement with 3-Pole Method with Additional Clamp (R 3P+C)
21
Earth Resistance Measurement with Two-Clamp Method (2C)
22
Soil Resistivity
23
RCD Parameters
24
Measurements in IT Networks
25
Automatic Measurements of RCD Parameters
26
Setting Automatic Measurements of RCD Parameters
26
Automatic Measurement of RCD Parameters
27
Insulation Resistance
29
Low-Voltage Measurement of Resistance
31
Measurement of Resistance
31
Measurement of Resistance of Protective Conductors and Equipotential Bonding with ±200 Ma Current
31
3.10 Sequence of Phases
32
3.11 Motor Rotation Direction
33
3.12 Illuminance
34
Resistance-To-Earth (PV)
34
Insulation Resistance (PV)
35
Continuity of Connections (PV)
35
Open Circuit DC Voltage U
36
Short Circuit DC Current I
37
Test of the Inverter Panel Η, P, I
38
3.18.1 Measurement Configuration
39
3.18.2 Live Mode
40
Resetting C-PV Clamp
41
Irradiance and Temperature
41
Auto Measurements
42
Proceeding Auto Measurements
42
Creating Measurement Procedures
44
Recorder
46
Functional Description
46
Main Elements of the Screen
48
Main Menu
48
Information Bar on the Parameters of the Current Network
49
Help
49
Connecting the Measuring System
49
Measuring Arrangements
49
Recording Configuration
52
Analyzer Settings
53
LIVE Mode of the Network
54
Transient Waveforms of Current and Voltages (Waveforms)
54
Timeplot of Effective Values
54
Live" Mode - Tabular View
54
Vector Diagram of Fundamental Components (Phasor)
55
Harmonics Graph/Table
56
Switching the Recording On/Off
56
Recording Analysis
56
Energy Loss Calculator
57
Functional Description
57
Configuration of the Loss Calculator
58
Inverter Efficiency
58
Memory of the Meter
59
Memory of Measurements
59
Memory Settings
59
Structure of the Memory
60
Entering the Measurement Result
60
Recorder Memory
61
Microsd Memory Card
61
USB External Memory (Flash Drive)
61
Compatibility with Sonel Analysis Software
61
PC Connection and Data Transmission
62
Power Supply
62
Monitoring of the Battery Charge Status
62
Replacing Rechargeable Batteries
62
Charging the Rechargeable Batteries
62
Technical Data
63
Basic Data
63
Measurement of Alternating Voltages (True RMS)
63
Frequency Measurement
63
Measurement of Fault Loop Impedance Z
63
L-Pe , Z L-N , Z L-L
63
Measurement of Fault Loop Impedance Z
64
L-PE[RCD] (Without Triggering of RCD)
64
Measurement of Parameters of RCD
64
Measurement of Resistance-To-Earth R
65
Low-Voltage Measurement of Continuity of Circuit and Resistance
66
Measurement of Insulation Resistance
66
Light Measurements
67
8.1.10 Phase Sequence
68
8.1.11 Motor Rotation
68
Measurement of Open Circuit DC Voltage U
68
Measurement Od Short Circuit DC Current I
68
Recorder Data
68
Inputs
68
Sampling and RTC
69
Voltage Measurement
69
Measurement of Current (True RMS)
70
Frequency Measurement
70
Measuring Harmonics
71
Unbalance
71
Power and Energy Measurement
71
Other Technical Data
72
Accessories
73
Standard Accessories
73
Advertisement
Related Products
Sonel MPI-540
Sonel MPI-525
Sonel MPI-520
Sonel MPI-530
Sonel MPI-505
Sonel MPI-535
Sonel MPI-502F
Sonel MPI-507
Sonel MPI-536
Sonel MPI-506
Sonel Categories
Measuring Instruments
Test Equipment
Thermal cameras
Laboratory Equipment
Adapter
More Sonel Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL