Sonel MIC-10k1 User Manual (72 pages)
Insulation Resistance Meter
Brand:
Sonel
| Category:
Measuring Instruments
| Size: 3 MB
Table of Contents
Table of Contents
5
Safety
7
Menu
8
Wireless Transmission
8
Measurement Settings
9
Mains Frequency
9
Times T1, T2, T3 for Calculating Absorption Coefficients
10
Type of Absorption Coefficients
10
Setting Limit Values
11
ISO Short-Circuit Current
11
Temperature and Distance Units
12
Auto-Incrementing of the Memory Cell Number
12
Filter
13
Chart Type Selection
13
Meter Settings
14
LCD Contrast
14
Automatic Shut-Off (Auto-OFF)
15
Date and Time
15
Factory (Default) Settings
16
Firmware Update
16
Button Sounds
17
Wireless Communication
18
Language Choice
18
Information about Manufacturer
18
Measurements
19
Diagnostics Performed by the Meter - Limits
19
Measurement of Insulation Resistance
19
Double-Lead Measurement
20
Three-Lead Measurement
27
Measurements with Autoiso-5000
29
Measurements with Increasing Voltage - SV
33
Dielectric Discharge Indicator - DD
34
Damage Location (After-Burning)
37
Low-Voltage Measurement of Resistance
38
Measurement of Resistance of Protective Conductors and Equipotential Bonding with ±200 Ma Current
39
Calibration of Test Leads
40
Correcting the R
41
ISO Value to the Reference Temperature
41
Determining the Length of the Tested Cable
42
Tightness Test of MV Cable Jacket
43
Memory of Measurement Results
44
Structure of the Memory
44
The Appearance of Main Windows in the Measurement Recording Mode
44
Storing the Measurement Results in the Memory
46
Entering the Results Without Extending the Memory Structure
46
Extending the Memory Structure
47
Viewing Memory Data
52
Deleting Memory Data
54
Data Transmission
55
Set of Accessories to Connect the Meter to a PC
55
Data Transmission through USB Port
55
Connecting to Bluetooth Mini-Keyboard
56
Manual Connection
56
Automatic Connection
58
Data Transmission Using Bluetooth Module
58
Read-Out and Change of PIN Code for Bluetooth Connections
59
Power Supply of the Meter
60
Monitoring the Power Supply Voltage
60
Battery Power
60
Charging Rechargeable Battery
61
Power Supply from Mains
61
General Principles for Using Li-Ion Rechargeable Batteries
62
General Principles for Using Gel (Lead) Rechargeable Batteries
62
Cleaning and Maintenance
63
Storage
63
Dismantling and Utilisation
63
Technical Specifications
64
Basic Data
64
Other Technical Data
67
Additional Data
68
Additional Uncertainties According to en 61557-2
68
Iso )
68
Additional Uncertainties According to en 61557-4
68
Cont )
68
Accessories
68
Standard Accessories
68
Optional Accessories
69
Manufacturer
70
Advertisement
Sonel MIC-10k1 User Manual (72 pages)
INSULATION RESISTANCE METER
Brand:
Sonel
| Category:
Measuring Instruments
| Size: 3 MB
Table of Contents
Table of Contents
5
Safety
7
Menu
8
Wireless Transmission
8
Measurement Settings
9
Mains Frequency
9
Times T1, T2, T3 for Calculating Absorption Coefficients
10
Type of Absorption Coefficients
10
Setting Limit Values
11
ISO Short-Circuit Current
11
Temperature Unit
12
Auto-Incrementing of the Memory Cell Number
12
Filter
13
Chart Type Selection
13
Meter Settings
14
LCD Contrast
14
Automatic Shut-Off (Auto-OFF)
15
Date and Time
15
Factory (Default) Settings
16
Software Update
16
Key Sounds
17
Wireless Communication
18
Language Selection
18
Information about Manufacturer
18
Measurements
19
Diagnostics Performed by the Meter - Limits
19
Measurement of Insulation Resistance
19
Double-Lead Measurement
20
Three-Lead Measurement
26
Measurements with Autoiso-5000
28
Measurements with Increasing Voltage - SV
32
Dielectric Discharge Indicator - DD
33
Damage Location (After-Burning)
36
Low-Voltage Measurement of Resistance
37
Measurement of Resistance of Protective Conductors and Equipotential Bonding with ±200 Ma Current
38
Calibration of Test Leads
39
Correcting the R
40
ISO Value to the Reference Temperature
40
Determining the Length of the Tested Cable
41
Tightness Test of MV Cable Jacket
42
Memory of Measurement Results
43
Structure of the Memory
43
The Appearance of Main Windows in the Measurement Recording Mode
43
Storing the Measurement Results in the Memory
45
Entering the Results Without Extending the Memory Structure
45
Extending the Memory Structure
46
Viewing Memory Data
51
Deleting Memory Data
53
Data Transmission
54
Set of Accessories to Connect the Meter to a PC
54
Data Transmission through USB Port
54
Data Transmission Using Bluetooth Module
55
Read-Out and Change of PIN Code for Bluetooth Connections
55
Power Supply of the Meter
57
Monitoring the Power Supply Voltage
57
Battery Power
57
Charging Rechargeable Battery
58
Power Supply from Mains
58
General Principles for Using Li-Ion Rechargeable Batteries
59
General Principles for Using Gel (Lead) Rechargeable Batteries
59
Cleaning and Maintenance
60
Storage
60
Dismantling and Utilisation
60
Technical Specifications
61
Basic Data
61
Other Technical Data
64
Additional Data
65
Additional Uncertainties According to en 61557-2
65
Iso )
65
Additional Uncertainties According to en 61557-4
65
Cont )
65
Accessories
65
Standard Accessories
65
Optional Accessories
66
Manufacturer
67
Laboratory Services
68
Sonel MIC-10k1 User Manual (70 pages)
Insulation Resistance Meters
Brand:
Sonel
| Category:
Measuring Instruments
| Size: 2 MB
Table of Contents
Table of Contents
7
1 Safety
9
2 Menu
10
Wireless Transmission
10
Measurement Settings
11
Mains Frequency
11
Times T1, T2, T3 for Calculating Absorption Coefficients
12
Type of Absorption Coefficients
12
IISO Test Current
12
Setting Limit Values
13
Temperature Unit
13
Auto-Incrementing of the Memory Cell Number
14
Filter
14
Chart Type Selection
14
Meter Settings
15
LCD Contrast
16
Automatic Shut-Off (Auto-OFF)
16
Date and Time
16
Factory (Default) Settings
17
Software Update
17
Key Sounds
18
Wireless Communication
18
Language Choice
19
Information about Manufacturer
19
3 Measurements
19
Diagnostics Performed by the Meter - Limits
20
Measurement of Insulation Resistance
20
Double-Lead Measurement
21
Three-Lead Measurement
26
Measurements with Autoiso-5000
28
Measurements with Increasing Voltage - SV
31
Dielectric Discharge Indicator - DD
33
Damage Location (After-Burning)
35
Low-Voltage Measurement of Resistance
37
Measurement of Resistance of Protective Conductors and Equipotential Bonding with ±200 Ma Current
37
Calibration of Test Leads
39
Temperature Measurement
40
4 Memory of Measurement Results
41
Structure of the Memory
41
The Appearance of Main Windows in the Measurement Recording Mode
41
Storing the Measurement Results in the Memory
43
Entering the Results Without Extending the Memory Structure
43
Extending the Memory Structure
44
Viewing Memory Data
49
Deleting Memory Data
51
5 Data Transmission
52
Set of Accessories to Connect the Meter to a PC
52
Data Transmission through USB Port
52
Connecting to Bluetooth Mini-Keyboard
53
Manual Connection
53
Automatic Connection
55
Data Transmission Using Bluetooth Module
55
Read-Out and Change of PIN Code for Bluetooth Connections
56
6 Power Supply of the Meter
57
Monitoring the Power Supply Voltage
57
Battery Power
57
Charging Rechargeable Battery
57
Power Supply from Mains
58
General Principles for Using Li-Ion Rechargeable Batteries
58
General Principles for Using Gel (Lead) Rechargeable Batteries
59
7 Cleaning and Maintenance
59
8 Storage
60
9 Dismantling and Utilisation
60
10 Technical Specifications
60
Basic Data
60
Additional Data
63
Additional Uncertainties According to en 61557-2
63
Iso )
63
Additional Uncertainties According to en 61557-4
64
Cont )
64
11 Equipment
64
Standard Equipment
64
Optional Accessories
64
12 Manufacturer
66
Advertisement
Sonel MIC-10k1 Operating Manual (68 pages)
INSULATION RESISTANCE METERS
Brand:
Sonel
| Category:
Measuring Instruments
| Size: 2 MB
Table of Contents
Table of Contents
7
1 Safety
9
2 Menu
10
Wireless Transmission
10
Measurement Settings
11
Mains Frequency
11
Times T1, T2, T3 for Calculating Absorption Coefficients
12
Type of Absorption Coefficients
12
I Test Current
12
Setting Limit Values
13
Temperature Unit
13
Auto-Incrementing of the Memory Cell Number
14
Filter
14
Chart Type Selection
14
Meter Settings
15
LCD Contrast
16
Automatic Shut-Off (Auto-OFF)
16
Date and Time
16
Factory (Default) Settings
17
Software Update
17
Key Sounds
18
Wireless Communication
18
Language Choice
18
Information about Manufacturer
19
3 Measurements
20
Diagnostics Performed by the Meter - Limits
20
Measurement of Insulation Resistance
20
Double-Lead Measurement
21
Three-Lead Measurement
26
Measurements with Autoiso-5000
29
Measurements with Increasing Voltage - SV
32
Dielectric Discharge Indicator - DD
33
Damage Location (After-Burning)
36
Low-Voltage Measurement of Resistance
37
Measurement of Resistance of Protective Conductors and Equipotential Bonding with ±200 Ma Current
37
Calibration of Test Leads
39
Temperature Measurement
40
4 Memory of Measurement Results
41
Structure of the Memory
41
The Appearance of Main Windows in the Measurement Recording Mode
41
Storing the Measurement Results in the Memory
43
Entering the Results Without Extending the Memory Structure
43
Extending the Memory Structure
45
Viewing Memory Data
50
Deleting Memory Data
52
5 Data Transmission
53
Set of Accessories to Connect the Meter to Apc
53
Data Transmission through Usb Port
53
Connecting to Bluetooth Mini-Keyboard
54
Manual Connection
54
Automatic Connection
56
Data Transmission Using Bluetooth Module
56
Read-Out and Change of PIN Code for Bluetooth Connections
57
6 Power Supply of the Meter
58
Monitoring the Power Supply Voltage
58
Battery Power
58
Charging Rechargeable Battery
58
Power Supply from Mains
59
General Principles for Gel Using (Lead) Rechargeable Batteries
59
7 Cleaning and Maintenance
60
8 Storage
60
9 Dismantling and Utilisation
60
10 Technical Specifications
61
Basic Data
61
Additional Data
64
Additional Uncertainties According to en 61557-2 (R )
64
Additional Uncertainties According to en 61557-4 (R )
64
11 Equipment
64
Standard Equipment
64
Optional Accessories
65
12 Manufacturer
66
Sonel MIC-10k1 User Manual (4 pages)
Brand:
Sonel
| Category:
Keyboard
| Size: 0 MB
Table of Contents
Introduction
2
Package Content
2
Description
2
Establishing a Connection with the Meter
3
Charging Rechargeable Battery
3
Access to the Extended Keyboard Characters
4
Sonel MIC-10k1 Quick Start Manual (2 pages)
Insulation Resistance Meter
Brand:
Sonel
| Category:
Measuring Instruments
| Size: 0 MB
Advertisement
Related Products
Sonel MIC-10
Sonel MIC-10s1
Sonel MIC-15k1
Sonel MIC-2501
Sonel MIC-30
Sonel MIC-5050
Sonel MIC-5001
Sonel MIC-2510
Sonel MIC-2
Sonel MIC-5
Sonel Categories
Measuring Instruments
Test Equipment
Thermal cameras
Laboratory Equipment
Adapter
More Sonel Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL