Sign In
Upload
Manuals
Brands
Sime Manuals
Chiller
SHP M ECO 008A KA
Sime SHP M ECO 008A KA Manuals
Manuals and User Guides for Sime SHP M ECO 008A KA. We have
1
Sime SHP M ECO 008A KA manual available for free PDF download: Manual
Sime SHP M ECO 008A KA Manual (40 pages)
Chiller and Inverter Air/Water heat pumps with axial fans
Brand:
Sime
| Category:
Chiller
| Size: 0 MB
Table of Contents
Table of Contents
3
How to Keep the Manual
6
Graphic Symbols Used in the Manual
6
Permitted Used
6
General Safety Guidelines
6
Personal Protective Equipment
6
Workers' Health and Safety
6
Purpose and Contents of the Manual
8
User Interface - Controller
9
Menu
9
Setpoint Menu
9
Password Menu [Pss]
10
Probes Menu [Tp]
10
Alarms Menu [Err]
10
Digital Inputs Menu [ID]
10
Parameters Menu [Par]
10
Operating Hours Menu [Ohr]
11
Menu Versione Firmware [Fir]
11
Log Menu [Hist]
11
Usb Menu [Usb]
11
Firmware Update [Updf]
11
Parameters Update [Uppa]
11
Display
11
Led
12
Terminal Block
12
Editing Dynamic Set-Point
13
Settings for Standard Climatic Curves
13
Edit the Set-Point from 0-10V Input or from Ratiometric Input
14
Circulator
15
Continuous Operation [P03=0] - Default
15
Operation on Call by Temperature Controller [P03=1]
15
Operating on Call by Temperature Controller with Periodic Activation
15
Operation with Heater Active
15
Proportional Regulation of the Circulator
15
System Venting
16
Compressor or Activation Logic
16
Regulation in Cooling Mode
16
Regulation in Heat Mode
16
Dissipation Fan Control
17
Controller Functions
17
Antifreeze Protection Heaters (if Ka Accessory Is Available)
17
Enabling Domestic Hot Water Production
17
Memorising the Probe in Heating Mode
18
Heating Mode on Dhw Storage Tank
18
Insufficient Heat Exchange in a Dhw System
18
Remote-Controlled Functions
18
On/Off
18
Summer/Winter Mode Change
18
Dhw Enable from Digital Input
18
System Water Remote Probe
19
Auxiliary Heaters
19
Plant Heater
19
Plant Heater in Defrost
19
Dhw Heater
19
Single Plant/Dhw Integration Heater
20
Integration Heater Selection Mode
20
Circulator Management with Heater on
20
Boiler Enabling
20
Activation of Integration Heaters and Boiler in Joint Operation and in Substitution of Heat Pump Compressor
20
Operation in Heat Pump Mode
21
Joint Operation (I Bracket)
21
Joint Operation (II Bracket)
21
Operation in Substitution
21
Operating Brackets - Activation of Integration Heaters (Plant Remote Water Probe Not Enabled)
21
Auxiliary Systems Offset Management
24
Warnings
25
Plant Season
25
Alarm
25
Machine Block
25
Defrost
25
Defrost Cycle
25
Compressor Crankcase Heater
25
Double Set-Point
25
Minimum Hz Functionality
25
Maximum Hz Functionality
26
Flowmeter
26
Functions that Can be Activated with Hi-T2 Accessory (Optional)
26
Functions that Can be Activated with Gi Module (Optional)
27
Tables of Permitted Setups for User and Installer
27
Alarms
30
E006] Flow Switch
31
E018] High-Temperature
31
E020] Inverter Trasductors
31
E005] Antifreeze
31
E611÷E681] Probe Alarms
31
E801] Timeout Inverter
31
E851 ÷E971] Inverter
31
E00] Remote On/Off (Warning)
31
E001] High-Pressure
31
E002] Low-Pressure
31
Power Failure
32
Utilities Block Alarm Table
32
Modbus Variables
32
Advertisement
Advertisement
Related Products
Sime SHP M ECO 006A KA
Sime SHP M ECO 008 A SL KA
Sime SHP M ECO 006A
Sime SHP M ECO 008A
Sime SHP M ECO 012 KA
Sime SHP M ECO 012 SL KA
Sime SHP M ECO 014KA T
Sime SHP M ECO 016KA T
Sime SHP M ECO 012T
Sime SHP M ECO 016
Sime Categories
Boiler
Water Heater
Burner
Irrigation System
Remote Control
More Sime Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL