Sign In
Upload
Manuals
Brands
SILENT KNIGHT Manuals
Fire Alarms
INTELLIKNIGHT 5820XL-EVS
SILENT KNIGHT INTELLIKNIGHT 5820XL-EVS Manuals
Manuals and User Guides for SILENT KNIGHT INTELLIKNIGHT 5820XL-EVS. We have
1
SILENT KNIGHT INTELLIKNIGHT 5820XL-EVS manual available for free PDF download: Installation And Operation Instruction Manual
SILENT KNIGHT INTELLIKNIGHT 5820XL-EVS Installation And Operation Instruction Manual (236 pages)
Addressable Fire System Emergency Voice System
Brand:
SILENT KNIGHT
| Category:
Fire Alarms
| Size: 5 MB
Table of Contents
Installation Procedure
2
Table of Contents
3
Section 1
11
Introduction
11
Overview of Basic System
11
Addressable Fire Alarm Control/Communicator Hardware Features
11
5820XL-EVS Emergency Voice Hardware Features
11
Software Features
12
About this Manual
12
Terms Used in this Manual
12
Compatible Products
13
How to Contact Silent Knight
14
Section 2
17
Agency Listings, Approvals, and Requirements
17
Section
17
Federal Communications Commission (FCC)
17
Underwriters Laboratories (UL)
18
Requirements for All Installations
18
Requirements for Central Station Fire Alarm Systems
18
Requirements for Local Protected Fire Alarm Systems
19
Requirements for Remote Station Protected Fire Alarm Systems
19
Section 3
20
Before You Begin Installation
20
What's in the Box
20
Environmental Specifications
20
Electrical Specifications
21
Wiring Specifications
22
Board Assembly Diagram
24
Calculating Current Draw and Standby Battery
25
Current Draw Worksheet Requirements
25
Current Draw Worksheet for SK SLC Devices
25
Current Draw Worksheet for SD SLC Devices
29
Maximum Battery Standby Load
31
Installation Tasks Overview
31
Section 4
34
Control Panel Installation
34
Mounting the Control Panel Cabinet
34
Preventing Water Damage
34
Removing the 5820XL / 5820XL-EVS Assembly from the Housing
34
AC Connection
34
Battery Connection
35
RBB Accessory Cabinet
36
Installing the RBB Accessory Cabinet and Batteries
36
SBUS Wiring
37
Calculating Wiring Distance for SBUS Modules
38
Wiring Configurations
40
5860 Remote Annunciator Installation
41
Mounting the 5860
42
Flush Mounting
43
Surface Mounting
45
Model 5860 Connection to the Panel
45
5815XL Installation
45
5815XL Connection to the Panel
46
5824 Serial/Parallel Interface Module Installation
47
Selecting 5824 Options
48
5880 LED I/O Module
49
5880 Board Layout
49
5880 Connection to Panel
49
LED Wiring
51
Dry Contact Wiring
51
5865-3 / 5865-4 LED Annunciator Installation
53
5865 Connection to Panel
53
5865 Mounting
54
Configuring Modules
55
Assigning SBUS Module Ids
55
Telephone Connection
56
Flexputs ™ I/O Circuits
56
Conventional Notification Appliance
56
Class B Notification Wiring
57
Class a Notification Wiring
57
Conventional Input Switch Circuits
58
Class B Inputs
59
Class a Inputs
59
Installing 2-Wire Smoke Detectors
60
Installing 2-Wire Class B Smoke Detectors
60
Installing 2-Wire Class a Smoke Detectors
61
Installing 4-Wire Smoke Detectors
61
Installing 4-Wire Class B Smoke Detectors
61
Installing 4-Wire Class a Smoke Detectors
62
Auxiliary Power Installation
63
Door Holder Power
63
Constant Power
63
Resettable Power
63
Sounder Sync Power
64
On-Board Relays (Conventional)
64
Trouble Relay
64
Programmable Relays
64
Remote Station Applications
64
Keltron Model 3158 Installation
64
City Box Connection Using the 5220 Module
65
NFPA 72 Polarity Reversal
66
Using the 5220 Module
66
Using the 7644* Module
67
Using the SD500-ARM Addressable Relay Module
68
Using a MR-201/T Control Relay from Air Products
68
Transmitter Activated by Dry Contacts
70
Section 5
71
SK SLC Device Installation
71
List of SK SLC Devices
71
List of SD SLC Devices
72
Maximum Number of Devices
72
Wiring Requirements for SLC Devices
73
Wiring 5815XL in Style 4 (Class B) Configuration
73
Wiring 5815XL in Style 6 & 7 (Class A) Configuration
75
Wiring SK SLC Detectors
75
Addressing SK SLC Devices
76
Wiring SD SLC Detectors
77
Addressing SD Devices
77
SD505-APS, SD505-AHS, and SD505-AIS
77
SLC Devices with DIP Switches
79
Section 6
80
Programming Overview
80
Jumpstart Autoprogramming
80
Input Points
81
Output Points
81
Running Jumpstart Autoprogramming
81
Section
80
Security and Data Protection
80
Mapping Overview
83
Input Point Mapping
84
Output Circuit Mapping
85
Zone Event Mapping
86
Mapping LED Points
88
Programming Using the 5660 Silent Knight Software Suite
88
Programming Using an Annunciator
89
Entering / Exiting the Program Menu
89
Moving through the Menus
90
Selecting Options and Entering Data
90
Editing Keys
91
Programming Menu Quick Reference
92
Section 7
109
Programming
109
UL 864 / UL 2572 Programming Requirements
109
Modules
109
Edit Modules
110
Naming Modules
110
Editing Module Features
110
Adding a Module
110
Deleting a Module
111
View Module List
111
Zone
111
Edit Zone
111
Edit Zone Name
112
Edit Zone Properties
112
Zone Outputs
113
Cadence Patterns
115
Zone Accessory Options
116
Add Zone
117
Delete Zone
117
View Zone Points
117
Group
118
Edit Group
118
Edit Group Name
118
Edit Group Properties
119
Add Group
120
Delete Group
120
View Group Points
121
Edit Output Group Templates
121
Point
122
Point Programming for 5815XL Module
122
Point Programming for Internal or External Power Module
126
Point Programming for 5880, 5865, EVS-50W, EVS-100W, EVS-125W and EVS-CE4 Modules
128
Point Programming for EVS-VCM and EVS-RVM Modules
128
Assigning a Name to Points
129
System Options
130
Reporting Account
130
Edit Accounts
130
Auto Test Time
132
Phone Lines
132
Dialing Prefix
133
Number of Answer Rings
133
Dial Option (Touchtone or Pulse)
134
Rotary Format
134
Line Monitor
134
Answering Machine Bypass
134
System Event Outputs
134
Trouble Events
135
System Alarm Cadence
135
Time Options
136
Water Flow Delay
136
Alarm Verification Time
136
Low AC Report Delay
137
Clock Display Format (AM/PM or Military)
137
Change AC Line Frequency
137
Miscellaneous Options
137
Synchronize Strobes Active During Silence
137
Auto Display Oldest Event
138
Report by Zone or by Point
138
Plex Door Option
138
Single Key Acknowledge
138
Daylight Savings
138
Automatic Daylight Savings Adjustment
138
Daylight Saving Time Start and End
138
Edit Banner
139
SLC Family
140
Jumpstart Autoprogramming
140
Computer Account
141
Access Codes
141
Profile Edit Menu
143
Edit Name
143
Edit Access Code
143
Panel Functions
143
Voice Options
143
EVS-VCM Maintenance
143
PC Connection
143
Local Recording
143
Edit Voice Commands
144
EVS System Options
144
Enable EVS System
144
Edit Command Priority
145
Edit Command Mapping
145
Edit Timers
145
Edit Event Names
146
Section 8
147
System Operation
147
Annunciator Description
147
LCD Display
147
Banner
147
Section
147
User and Installer Default Codes
147
Key Operation
148
Menu System
148
Main Menu Overview
149
Using the Menus
149
Basic Operation
149
Setting Time and Date
149
Disable / Enable a Point
149
Disable / Enable Nacs by Template
150
Disable / Enable Nacs by Group
150
Disable / Enable Zone Points
150
View Event History
150
To Clear the Event History
150
Conduct a Fire Drill
150
Conduct an Indicator Test
150
Conduct a Walk Test
151
Conduct a Dialer Test
151
Silence Alarms or Troubles
151
Reset Alarms
152
Check Detector Sensitivity through Point Status
152
View Status of a Point
153
View Alarms, Supervisories or Troubles
153
View System Information
153
Reset Items
153
Reset Dialer
153
Reset DSP USB
153
Communicating with a Remote Computer
154
Working with a Printer
155
Operation Mode Behavior
156
Releasing Operations
161
Single Interlock Zone Releasing
162
Double Interlock Zone Releasing
163
Smoke Alarm Verification
164
Section 9
165
Emergency Voice System Operation
165
Overview
165
Section
165
LOC Functionality
165
Keys and Leds
165
EVS Control Key
165
EVS Control LED
166
ALL CALL Key
166
NON-ACTIVE CALL Key
166
EVS Message Keys
166
EVS Message Leds
166
Select Keys
166
Select Key Leds
166
Gaining EVS Control
167
LOC Priority
167
LOC Lockout
167
User Profile Access Control
168
Manual EVS
168
Switching between Microphone Mode and Message Mode
168
Activating/Deactivating Output Groups Dynamically
168
Microphone Mode
168
Message Mode
169
Custom EVS Event
169
Passing EVS Control
169
Exit EVS Control Menu
169
Relinquish EVS Control
169
EVS Reset
170
Access Control
170
EVS Super User
170
EVS Point Functionality
170
EVS Point Activations
170
EVS-VCM Points
171
Evs 5880
171
EVS (1-8) 5880 Module
171
Enable 5880 EVS
171
EVS LOC Programming
171
Adding an LOC
171
Editing an LOC
172
LOC Priority
172
LOC Association
172
Amplifier Programming
173
Adding an Amplifier
173
Editing an Amplifier
173
Event Priority
174
System Control
174
System Override
174
EVS Event Priority
174
View Active Alarms, Troubles and Supervisory Signals
175
Using the Microphone
175
Microphone Functionality
175
Custom EVS Event
175
Fire Page
176
Emergency Page
176
Paging
176
Recording Custom Messages
177
Recording Messages 1-15 Using Aux Audio Input
178
Recording Messages 1-15 Using the Microphone
180
Erasing User Message
181
Using EVS Message Manager Software
182
EVS Priority
183
Priority Rules
183
Defining Output Group Type
184
Voice Command Mapping
185
Voice System Mapping
185
EVS Voice Aux Inputs (Dynamic with VCM/RVM in the System)
185
Edit Command Mapping
187
Mapping for Voice Commands
187
EVS Timer Options
188
Timers Include
188
EVS Timer Menu
188
Reporting
189
Receivers Compatible with the Control Panel
189
Reporting Formats Table
189
Section
189
Testing and Troubleshooting
198
Troubleshooting
198
Common Problems
198
Periodic Testing and Maintenance
200
Event History
200
Built-In Troubleshooting and Testing Tools
200
SLC Device Locator
200
SLC Multiple Locator
202
I/O Point Control
203
Earth Fault Resistance
204
Section 12
205
Installation Records
205
Detector and Module Point Record
205
Conventional Output Point Record
209
Appendix A Compatible Device
211
Appendix B Special Characters Lists
224
Silent Knight Fire Product Warranty and Return Policy
225
Manufacturer Warranties and Limitation of Liability
226
Intelliknight 5820XL Basic Operating Instructions
227
5820XL-EVS Basic Operating Instructions
229
Advertisement
Advertisement
Related Products
Silent Knight INTELLIKNIGHT 5808
SILENT KNIGHT 5204
SILENT KNIGHT INTELLIKNIGHT 5820XL
SILENT KNIGHT 5895XL
SILENT KNIGHT 5083
SILENT KNIGHT 5084
Silent Knight 5104B
Silent Knight 5700
SILENT KNIGHT 5499
SILENT KNIGHT 5128
SILENT KNIGHT Categories
Fire Alarms
Control Panel
Security System
Cell Phone
Smoke Alarm
More SILENT KNIGHT Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL