Sign In
Upload
Manuals
Brands
Shinko Denshi Manuals
Scales
FZ100K1GEx
Shinko Denshi FZ100K1GEx Manuals
Manuals and User Guides for Shinko Denshi FZ100K1GEx. We have
1
Shinko Denshi FZ100K1GEx manual available for free PDF download: Operation Manual
Shinko Denshi FZ100K1GEx Operation Manual (108 pages)
Intrinsically Safe Explosion-Proof High-Precision Tuning Fork Scale, FZ-Ex Series
Brand:
Shinko Denshi
| Category:
Scales
| Size: 4 MB
Table of Contents
Important Notice
5
How to Use this Document
6
Table of Contents
8
1 Prior to Use
11
Precautions
11
Names and Functions of each Section
13
Performance of Operation Keys
14
How to Interpret the Display
15
Main LCD
15
Sub Lcds ( I03 Only)
16
LCD Character Font
16
2 Basic Usage
17
Turning on / off the Power, and Checking for the Operation
17
Making a Zero Adjustment
18
Zero Adjustment Range When in Use
19
Weighing an Object Placed on a Container (Tare)
20
Weighing with an Object to be Weighed Added
21
Selecting the Main LCD Indication
22
Selecting the Sub LCD Indication ( I03 Only)
22
Basic Operation
23
Hierarchy of a Setting Menu
23
Operation of the Setting Menu, Setting of Various Functions
24
Operation of the Setting Menu, Inputting of Numeric Values
26
Operation of the Setting Menu, Inputting of Characters
27
3 Functions Related to the Operation
29
Hierarchy of Functions Related to the Operation
29
Unit Setting
30
Percent Scale Function
30
Adding Function
31
Weighing by Means of the Plus Side Addition
32
Weighing by Means of the Minus Side Addition
33
Comparator Function
34
How to Perform Discrimination
34
Discrimination Criteria, and Upper and Lower Limits Setting
34
Comparator Function Setting
35
Buzzer Setting
36
Bar Graph Indication
36
Conditions for Stability Waiting
37
Tare Weight Value Storage Function
37
Direct Start
38
Auto Power-Off
38
4 Function Srelated to the Performance
39
Hierarchy of Functions Related to the Performance
39
Zero Tracking
40
Stability Discrimination Width
40
Stability Discrimination Frequency
41
Response Speed
41
Weight Renewal Interval
42
5 User Information Setting
43
Hierarchy of User Information Setting
43
Measurer's ID Setting
43
Product Name ID Setting
44
Lot Number Setting
44
Code Number Setting
44
Preset Tare Weight Setting
45
Inputting of a Preset Tare Weight Value
45
Registration of a Preset Tare Weight Value
47
Calling of a Preset Tare Weight Value
47
Setting of a Percent Scale Reference Value
48
Setting of the Discrimination Value of the Comparator Function
49
Numeric Value Setting Method
49
Actual Value Setting Method
52
Coefficient Value Setting
55
6 External Input/Output Functions
56
Hierarchy of the External Input/Output Functions
56
Connecter Terminal Numbers and Their Functions
57
FZ Communication Format (CRC Provided)
57
GZIII Format
57
Basic Communication Specification
57
Basic Data Output Format
58
Meaning of the Data
58
Input Command Composition
59
Transmission Procedure
59
Command Format
60
GZII Format
61
Command Format
61
Response
62
Response Command Format (When Set to the A00, Exx Format)
62
Response Command
62
Response Command Format (When Set to the ACK, NAK Format)
62
External Contact Input (Tare Weight Subtraction / Zero Adjustment / Tare Weight Subtraction & Zero Adjustment)
62
Power Supply Box Communication Setting
63
Maintenance Setting
65
7 Functions Related to the Lock
66
Hierarchy of Functions Related to the Lock
66
Locking of Functions Related to the Operation
66
Key Lock Function
67
Total Lock Release
67
8 Controlling and Adjustment Functions
68
Hierarchy of Controlling and Adjustment Functions
68
Outputting of the Span Adjustment Result
69
Span Adjustment History
69
Scale ID Setting
70
Maintenance Setting
70
Date and Time Setting
71
Date Indication Format
71
Output Character Setting
71
Password Control
72
Password Change
72
Password Cancellation History
73
Operation of Minimum Weight Indication
74
Minimum Weight Indication Value Setting
74
Designation of Minimum Indication
75
Reset to the Factory Settings
77
Span Adjustment
77
Setting for Maintenance
80
9 Execution Menu
81
Operation of the Execution Menu
81
Calling of the Registered User Information
82
Registration of User Information
83
Calling of Device Setting Information
84
Storage of Device Setting Information
84
Printing of the GLP Header
85
Printing of the GLP Footer
85
Program Number and Check Sum Indication
86
Outputting of Weight Data
87
Outputting of Tare Weight
87
Outputting of Gross Weight
87
Outputting of Accumulated Value
88
Indication of Minimum Weighed Value
88
10 Troubleshooting
89
Error Messages
89
Troubleshooting
92
Maintenance Method
92
Appendix
93
Appendix 1 Specification
93
Appendix 1-1 Connectable Scales
93
Appendix 1-2 Functional Specification
94
Appendix 1-3 Dimensional Outline Drawing
95
Appendix 2 Operation of the Setting Menu
96
Appendix 3 Setting Menu Hierarchy List
98
Appendix 4 Print Sample
103
Index of Terms
105
Advertisement
Advertisement
Related Products
Shinko Denshi FZ623Ex
Shinko Denshi FZ3202Ex
Shinko Denshi FZ6202Ex
Shinko Denshi FZ15001Ex
Shinko Denshi FZ60K0.1GEx
Shinko Denshi FZ30K0.1GEx
Shinko Denshi FZ200K1GEx
Shinko Denshi FZ150K1GFEx
Shinko Denshi FZ300K1GFEx
Shinko Denshi FS300K1GF
Shinko Denshi Categories
Scales
Printer
Accessories
Laboratory Equipment
More Shinko Denshi Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL