Sign In
Upload
Manuals
Brands
Seg Manuals
Protection Device
High PROTEC MRMV4
Seg High PROTEC MRMV4 Manuals
Manuals and User Guides for Seg High PROTEC MRMV4. We have
1
Seg High PROTEC MRMV4 manual available for free PDF download: Manual
Seg High PROTEC MRMV4 Manual (573 pages)
Brand:
Seg
| Category:
Protection Device
| Size: 10 MB
Table of Contents
Table of Contents
3
Safety Messages and Proper Use of the MRMV4
14
Important Definitions
14
Proper Use of the Device and of this Manual
16
Personal Safety
19
Important Information
20
MRMV4 - Motor Protection
21
Comments on the Manual
22
Symbols and Definitions
26
Legend for Wiring Diagrams
27
Symbols in Function Diagrams
29
Information about the Device
32
Order Form of the Device
34
Overview of Assembly Groups
36
Communication Protocol Codes
37
Navigation - Operation
39
Front Panel Parts
40
Softkey Symbols
42
Modules, Settings, Signals and Values
43
Parameter Settings
47
Setting Lock
51
Adaptive Parameter Sets
52
Status Display
55
Menu Structure
56
Device Planning
58
Field Parameters
59
Device Parameters
60
Reset Counters, Values and Records
61
Security
62
Network Security
63
Passwords
64
Connection Passwords, Smart View Access
65
Access Level Passwords
67
Access Levels
67
Reset to Factory Defaults, Reset All Passwords
72
Acknowledgments
74
Measuring Values
79
Statistics
81
Configuration of the Minimum and Maximum Values
81
Configuration of the Average Value Calculation
81
Configuration of the Current-Based Average Value Calculation
81
Configuration of the Voltage-Based Average Value Calculation
82
Configuration of the Power-Based Average Value Calculation
83
Smart View
84
Datavisualizer
84
Hardware
86
Dimension Drawings
86
MRMV4 - Installation and Wiring
90
Grounding
90
Overview of Slots - Assembly Groups
91
Slot X1
92
DI8-X Power Supply and Digital Inputs
93
Slot X2
97
Assembly Group with 6 Output Relays
98
Slot X3
100
TI - Standard Phase and Ground Current Measuring Input Card
101
Tis - Phase and Sensitive Ground Current Measuring Card
104
Current Transformers (CT)
107
Sensitive Ground Current Measurement
107
Current Transformer Connection Examples
108
Connecting the Current Inputs
113
CT Requirements
115
Slot X4
118
TU - Voltage Measuring Inputs
119
Voltage Transformers
122
Determination of the Residual Voltage VX for Various Connection Types
126
Calculation from the Three Phase-To-Ground Voltages
127
Measurement over the Broken Delta
128
Measurement at the Neutral Terminal (E. G. of the Generator)
129
Slot X5
130
AN-O4 - Assembly Group with 4 Analog Outputs
131
Slot X6
133
Slot X100: Ethernet Interface
134
Ethernet - RJ45
135
Slot X102
136
Interface for the URTD Module
137
Slot X103: Data Communication
138
Modbus® RTU / IEC 60870-5-103 Via RS485
139
Profibus DP/ Modbus® RTU / IEC 60870-5-103 Via Fiber Optic
143
Profibus DP Via D-SUB
144
Modbus® RTU / IEC 60870-5-103 Via D-SUB
145
Ethernet / TCP/IP Via Fiber Optics
146
Slot X104: IRIG-B00X and Selfsupervision Contact
147
Self-Supervision Contact (Sc)/Life-Contact and IRIG-B00X
148
PC Interface - X120
149
Input, Output and LED Settings
150
Leds
150
Configuration of the Digital Inputs
154
Output Relays Settings
156
Configuration of the Analog Outputs
159
Communication Protocols
162
General SCADA (Communication) Setting
162
TCP/IP Settings
163
Iec 61850
164
Dnp3
166
Application Example: Setting a Relay
169
Deadband Settings in DNP3
169
Configurable Communication Protocols
174
Iec60870-5-103
175
Iec 60870-5-104
178
Modbus
182
Profibus
187
Data-Point Mapping Using the Scadapter
188
Time Synchronization
190
Sntp
193
Irig-B00X
195
Protective Elements
197
Module Prot: General Protection
197
General Alarms and General Trips
199
Blockings
204
Blocking the Tripping Command
206
Activate, Deactivate or Block a Protection Function Temporarily
207
Activate, Deactivate or Block the Phase Current Modules
208
Activate, Deactivate or Block the Ground (Earth) Current Modules
210
Mstart - Motor Start and Control Module [48, 66]
212
Motor Start / Transition Trips
214
Start Control
216
Incomplete Sequence (Insq)
218
Zero Speed Switch (ZSS on or OFF)
219
Reversing or Non-Reversing Starter
220
Motor Start Blocked
221
Start Limits
223
Anti-Backspin Timer - "ABS Timer
224
Thermal Block
224
Remote Start Blocking
224
Delayed Protection Enabling During Motor Starts
225
Long Acceleration Time (LAT)
229
Motor Cold / Warm Detection
230
Emergency Override
231
Thm - Thermal Model [49M, 49R]
232
LRC - Locked Rotor During Start
236
UTC - Ultimate Trip Current
237
Motor Protection Curves
238
MLS - Mechanical Load Shedding
241
Commissioning: Mechanical Load Shedding
242
Jam - Locked Rotor Protection [51LR]
244
Commissioning: JAM [51LR]
245
I< - Undercurrent [37]
247
Commissioning: Undercurrent [ANSI 37]
249
I - Overcurrent Protection
251
Characteristics
253
DEFT - Definite Time-Overcurrent
253
Inverse-Time Characteristics (Phase Current)
256
Functionality
271
Voltage Restraint Overcurrent
272
I2> - Negative-Sequence Overcurrent [51Q]
274
Voltage Controlled Overcurrent Protection [51C]
276
I>> - IOC Function
277
Commissioning: Overcurrent Protection, Non-Directional [50, 51]
278
Commissioning: Overcurrent Protection, Non-Directional [ANSI 51V]
279
Commissioning: Negative Sequence Overcurrent
281
IG - Ground (Earth) Overcurrent Protection [50N/G, 51N/G, 67N/G]
282
Characteristics (Ground Current)
283
DEFT - Definite Time-Overcurrent
283
Inverse-Time Characteristics (Ground Current)
286
Ground (Earth) Overcurrent - Functionality
302
Special Notes on Earth Fault Current Transformers
304
Commissioning: Ground Fault Protection - Non-Directional [50N/G, 51N/G]
305
I2> and %I2/I1> - Unbalanced Load [46]
306
Commissioning: Current Unbalance Module
308
Voltage Protection [27,59]
311
Commissioning: Overvoltage Protection
316
Commissioning: Undervoltage Protection [27]
316
VG, VX - Voltage Supervision (Residual Voltage Protection) [27A, 59A]
317
Commissioning: Residual Voltage Protection - Measured [59N]
319
Commissioning: Residual Voltage Protection - Calculated [59N]
320
F - Frequency [81O/U, 78, 81R]
322
Operating Modes "F<", "F
324
Operating Mode "Df/Dt
326
Operating Modes "F< and Df/Dt", "F> and Df/Dt
329
Operating Mode "Delta Phi" - [ANSI 78V]
334
Commissioning: Overfrequency [F>]
339
Commissioning: Underfrequency [F<]
339
Commissioning: Df/Dt - ROCOF
339
Commissioning: F< and -Df/Dt - Underfrequency and ROCOF
340
Commissioning: F> and Df/Dt - Overfrequency and ROCOF
341
Commissioning: F< and DF/DT - Underfrequency and DF/DT
341
Commissioning: F> and DF/DT - Overfrequency and DF/DT
342
Commissioning: Delta Phi - Vector Surge
342
012 - Voltage Unbalance Protection [47]
343
Commissioning: Asymmetry Protection
344
PQS - Power [32, 37]
346
Setting the Thresholds
348
Commissioning Examples for the Power Protection Module
349
PF - Power Factor [55]
358
Commissioning: Power Factor [55]
359
Exp - External Protection
361
Commissioning: External Protection
361
RTD Protection Module [26/38/49]
363
URTDII Module Interface
368
Supervision
372
CBF - Circuit Breaker Failure [50BF*/62BF]
372
Principle - General Use
372
Functionality
375
Commissioning Example: Supervision Scheme 50BF
375
TCS - Trip Circuit Supervision [74TC]
377
Commissioning: Trip Circuit Supervision [74TC]
378
CTS - Current Transformer Supervision [60L]
380
Commissioning: Current Transformer Failure Supervision
381
LOP - Loss of Potential [60]
383
Loss of Potential - Evaluating Measured Quantities
383
Loss of Potential - Fuse Failure
384
Commissioning: Loss of Potential
386
Commissioning: Loss of Potential (FF Via DI)
386
Phase Sequence Supervision
388
Control / Switchgear-Manager
389
Switchgear Control
391
Settings Within the Protection Device
393
Switch
395
Invisible Switch
396
Circuit Breaker
397
Circuit Breaker1
398
Disconnector (Isolator)
399
Disconnector-Earthing Combination
400
Earthing Switch
401
Fuse-Load Switch
402
Fuse-Load Switch - Disconnector
403
Fused-Disconnector (Isolator)
404
Load Switch
405
Load Switch - Disconnector
406
Three Position Switch
407
Withdrawable Circuit Breaker
409
Withdrawable Fuse Load Switch
411
Switchgear Configuration
412
Switchgear Wear
421
Control - Example: Switching of a Circuit Breaker
424
System Alarms
426
Demand Management
426
Min. and Max. Values
428
THD Protection
429
Recorders
430
Disturbance Recorder
432
Fault Recorder
437
Behavior of the Fault Recorder
438
Fault Display Screen (Overlay / Pop-Up) on the Display
440
Content of a Fault Record
441
Check the Fault Recorder at the Panel of the MRMV4
441
Event Recorder
443
Trend Recorder
444
Motor Start Recorder
445
Statistic Recorder
448
History Function
449
Programmable Logic
450
Self-Supervision
456
Device Start (Reboot)
459
Syslog
462
Device Taken out of Service ("Device Stopped")
464
Commissioning
465
Commissioning/Protection Test
466
Putting out of Operation - Plug out the Relay
467
Service and Commissioning Support
468
General
468
Phase Sequence
468
Forcing the Relay Output Contacts
468
Disarming the Relay Output Contacts
469
Forcing Rtds
470
Forcing Analog Outputs
471
Fault Simulator (Sequencer)
472
Servicing and Maintenance
475
Routine Functional Tests
475
Technical Data, Specifications, Tolerances
477
Technical Data
477
Climatic and Environmental Data
477
Pollution Degree and Equipment Class
477
Degree of Protection en 60529
477
Routine Test
477
Housing
478
Current Measurement
478
Voltage and Residual Voltage Measurement
480
Frequency Measurement
481
Voltage Supply
481
Power Consumption
482
Display
482
Leds
482
Front Interface USB
482
Real Time Clock
482
Analog Outputs
482
Digital Inputs
483
Binary Output Relays
484
Supervision Contact (SC)
485
Time Synchronization IRIG-B00X
485
Rs485
485
URTD-Interface
486
Fiber Optic Module with ST Connector for SCADA Communication
487
Optical Ethernet Module with LC Connector
487
Smart View Connections
488
Self-Supervision Messages
488
Boot Phase
488
Setting Ranges
489
Specifications / Tolerances
490
Specifications of the Real Time Clock
490
Specifications of the Measured Value Acquisition
491
Protection Elements Accuracy
493
Phase Overcurrent Protection
493
Earth (Ground) Overcurrent Protection
495
Thermal Protection
497
Motor Protection
498
Current-Related Protection
500
Voltage-Related Protection
501
Frequency Protection
503
Power-Related Protection
505
Miscellaneous Protection and Supervision
508
Appendix
509
Standards
509
Approvals
509
Electrical Tests
511
Mechanical Tests
516
IEC 60870-103 Interoperability
518
Physical Layer
518
Link Layer
518
Application Layer
518
Common Address of ASDU
518
Selection of Standard Information Numbers in Monitor Direction
519
Selection of Standard Information Numbers in Control Direction
520
IEC 60870-5-104 Interoperability
522
System or Device
522
Network Configuration
522
Physical Layer
523
Link Layer
523
Application Layer
524
Basic Application Functions
530
Abbreviations, and Acronyms
535
List of ANSI Codes
542
Revision History
545
Version: 3.0
550
Version: 3.0.B
550
Version: 3.1
551
Version: 3.4
552
Version: 3.6
555
Version: 3.7
559
Index
562
Advertisement
Advertisement
Related Products
Seg MRD1-G
Seg MRD1-T
Seg HighPROTEC MRM4
Seg MCA4
Seg MCGDV4
Seg MRM3
Seg MRIK3
Seg MRP2
Seg MRF3
Seg MRIK3-C
Seg Categories
Relays
LED TV
Protection Device
LCD TV
TV
More Seg Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL