Sign In
Upload
Manuals
Brands
Scott Safety Manuals
Security Sensors
MultiFlame FV-40 Series
Scott Safety MultiFlame FV-40 Series Manuals
Manuals and User Guides for Scott Safety MultiFlame FV-40 Series. We have
1
Scott Safety MultiFlame FV-40 Series manual available for free PDF download: User Manual
Scott Safety MultiFlame FV-40 Series User Manual (89 pages)
Flame Detector
Brand:
Scott Safety
| Category:
Security Sensors
| Size: 2 MB
Table of Contents
Warranty
4
Warnings
4
Related Product Documentation
6
Release History
7
About this Guide
8
Abbreviations and Acronyms
9
Table of Contents
10
1 Introduction
15
Overview
15
Model and Types
16
Table 1: Base Part Number / Sensor Type
16
Table 2: Part Dash Number / Configuration Code
17
Table 3: Configuration Code Key
18
Features and Benefits
19
Principles of Operation
20
Detection Principles
20
Heated Optics
22
HART Protocol
23
RS-485 Modbus
23
Product Certification
23
Performance Considerations
25
Detection Sensitivity
25
Table 4: Detector Sensitivity Range Levels
25
Cone of Vision
26
Table 5: Fuel Sensitivity Ranges
26
False Alarms Prevention
27
Table 6: False Alarms Prevention
27
Table 7: Welding Immunity Distance
27
Visual Indicators
28
Figure 1: Indication LED
28
Table 8: LED Indications
28
Output Signals
29
Table 9: Available Output Types
29
Detector Status
30
Table 10: Detector Status
30
Table 11: Output Signals Versus Detector State
30
Auxiliary Relay as End-Of-Line Resistor
31
Internal Detector Tests
31
Built-In-Test (BIT)
32
Table 12: Result of a Successful BIT
33
Table 13: Results of an Unsuccessful BIT
33
Table 14: Results of a Successful Manual BIT
34
Table 15: Results of an Unsuccessful Manual BIT
34
2 Installing the Detector
35
General Guidelines
35
Unpacking the Product
36
Checking the Product Type
37
Required Tools
37
Table 16: Tools
37
General Instructions
38
Special Instructions for Safe Use
38
Table 17: Flame Path Dimensions
38
Installation Cables
40
Conduit Installation
40
Installing the Tilt Mount
41
Tilt Mount Assembly
41
Figure 2: Detector with Tilt Mount
41
Figure 3: Tilt Mount Assembly
42
Figure 4: Tilt Mount Assembly (Dimensions in MM and Inches)
42
Connecting the Detector
43
Verifying the Detector Wiring
44
Figure 5: Detector with Cover Removed
44
Table 18: FV-40 Series Wiring Options
44
Configuring Your Detector
45
Sensitivity
46
Alarm Delay
46
Table 19: Sensitivity Settings
46
Address Set-Up
47
Function Set-Up
47
Heated Optics
47
Table 20: Functions
47
3 Operating the Detector
49
Powering up
49
Safety Precautions
50
Default Functions Settings
50
Table 21: Default Function Values
50
Testing Procedures
51
Automatic BIT Test
51
Manual BIT Test
51
Testing with Flame Simulators
51
Table 22: Results of Successful Fire Simulator Test
52
4 Maintenance and Troubleshooting
53
Maintenance
53
General Procedures
53
Periodic Procedures
54
Keeping Maintenance Records
54
Troubleshooting
54
Table 23: Troubleshooting Table
55
Appendices
56
A Specifications
57
Technical Specifications
57
Electrical Specifications
60
Table 24: Electrical Specifications
60
A.2 Electrical Specifications
60
Outputs
61
Table 25: Contact Ratings
61
A.3 Outputs
61
Table 26: 20 Ma Current Output
62
Mechanical Specifications
63
Environmental Specifications
63
A.4 Mechanical Specifications
63
Table 27: Electromagnetic Compatibility (EMC)
64
B Wiring Instructions
65
General Instructions for Electrical Wiring
65
Table 28: Maximum DC Resistance at 68°F (20ºC) for Copper Wire
65
Table 29: Wiring Length in Feet (Meter)
66
Typical Wiring Configurations
67
Figure 6: Wiring Terminals
67
Figure 7: Typical Wiring for 4 Wire Controllers (Using Option 1 or 2 Wiring)
68
Table 30: Wiring Connections
68
Figure 8: 0-20Ma Wiring Option 1 (Sink 4-Wire) - Default
69
Figure 9: 0-20Ma Wiring Option 1 (Converted to Source 3-Wire)
69
Figure 10: 0-20Ma Wiring Option 1 (Non-Isolated Sink 3-Wire)
70
Figure 11: 0-20Ma Wiring Option 2 and
70
CRS-485 Communication Network
71
RS-485 Overview
71
Figure 12: RS-485 Networking
71
D Accessories
72
Long Range Flame Simulators
72
Figure 13: Flame Simulator 380114-1
72
D.1.1 Unpacking
73
Operating Instructions
73
Range
73
Table 31: Sensitivity Ranges
73
Unpacking
73
Charging the Battery
74
Figure 14: Flame Simulator Battery Replacement
74
D.1.5 Technical Specifications
76
Table 32: EMI Compatibility
76
Technical Specifications
76
Tilt Mount
77
Figure 15: Tilt Mount
77
D.2 Tilt Mount
77
Duct Mount
78
Figure 16: Duct Mount
78
D.3 Duct Mount
78
Weather Protection
79
Figure 17: Weather Protection
79
D.4 Weather Protection
79
Laser Detection Coverage Pointer
80
Figure 18: Laser Detection Coverage Pointer
80
Air Shield
81
Figure 19: Air Shield
81
D.6 Air Shield
81
SIL-2 Features
82
Safety Relevant Parameters
82
Guidelines for Configuring, Installing, Operating and Service
82
F F Online FV-40 Configurator Part Code
85
Table 33: Part Number Configuration (Online Ordering)
85
Table 34: Configurable Options (Online Ordering)
86
F.1 Technical Support
88
Technical Support
88
Advertisement
Advertisement
Related Products
Scott Safety FH6
Scott Safety FH62
Scott Safety FH1
Scott Safety FH2
Scott Safety FH21
Scott Safety FH61
Scott Safety FH31
Scott Safety FH3
Scott Safety FM3
Scott Safety FM2
Scott Safety Categories
Safety Equipment
Respiratory Product
Security Sensors
Diving Instrument
Measuring Instruments
More Scott Safety Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL