Manuals and User Guides for SCIEX PA 800 Plus. We have
3
SCIEX PA 800 Plus manuals available for free PDF download: Development Manual, System Maintenance Manual, System Overview Manual
SCIEX PA 800 Plus Development Manual (158 pages)
Pharmaceutical Analysis System Methods Development Guide
Brand:
SCIEX
| Category:
Laboratory Equipment
| Size: 4 MB
Table of Contents
Example
2
Table of Contents
3
CHAPTER 1 About this Guide
9
Overview
9
Data
10
Purpose of These Files
11
Using the Files
11
Instructions for Using the Sample
10
CHAPTER 2 Introduction to Capillary
13
Overview
13
General Description
13
Electrophoresis
13
Common Modes of Electrophoresis
14
Capillary Zone Electrophoresis
14
Micellar Electrokinetic Capillary Chromatography
14
Capillary Gel Electrophoresis
14
Capillary Isoelectric Focusing
14
(Cze)
14
(Cge)
14
(Cief)
14
Capillary Electrochromatography
15
(Cec)
15
CHAPTER 3 System Overview
17
The Sample Handling System
19
Capillary Cartridge
22
Fluid Delivery, Power Supply and Syringe Pump
24
High Voltage Power Supply
24
LED Indicators
24
Cartridge and Sample Cover
24
Interlock
24
Interlocks
24
UV Detector Optics
25
The Photodiode Array (PDA) Detector
26
Detector
27
Laser Module
29
488 Nm Laser Module
29
Laser-Induced Fluorescence (LIF)
27
CHAPTER 4 32 Karat Software
31
Starting the Software
31
Tool Bar
32
Menu Bar
32
Creating and Configuring an Instrument
32
Creating a New Instrument
33
Configuring the New Instrument
33
Auto Configuration
35
Configuration Options
37
Analysis Options
37
Pda
37
System Suitability
37
Qualitative Analysis
38
Caesar Integration
38
Instrument Options
38
Standard CE
38
Cec/Lc
38
Manual Configuration
39
Manual Configuration of the UV Detector
39
Manual Configuration of the PDA and LIF Detectors
40
Instrument
17
CHAPTER 5: Direct Control
41
Introduction
41
Direct Control Window
41
Exercise: Conditioning the Capillary
44
CHAPTER 6: Creating and Editing a Method
49
Introduction
49
Creating and Editing a Method
49
Initial Conditions Tab
50
Detector Initial Conditions
52
UV Detector Initial Conditions
52
Electropherogram Channel
53
Filter
53
Relay 1 and Relay 2
53
Absorbance Signal
53
PDA Detector Initial Conditions
54
Electropherogram Scan Data
54
Filter
54
Relay 1 and Relay 2
54
Reference Channel
55
Absorbance Signal
55
Electropherogram Channel Data
55
LIF Detector Initial Conditions
56
Electropherogram Channel 1 and 2
56
Signal
57
Data Rate
57
Relay 1 and 2
57
Time Program
57
Separate Dialog
58
Rinse Dialog
61
Inject Dialog
61
Autozero
63
Stop Data
63
End
63
Saving the Method
67
CHAPTER 7 Running the System
69
Single Run and Sequence Runs
69
Materials Needed
69
Single Run
70
Programming a Sequence
72
Running the Sequence
77
Sequence Validation
78
CHAPTER 8 Integration
81
Description
81
Integrating Data
82
Optimizing Integration
84
Integration Parameters
85
Width
86
Threshold
87
Integrating a Peak Cluster
88
Integration off
89
Integration Results and Reports
91
CHAPTER 9 Calibration
93
Introduction
93
Analysis Components
93
Qualitative Analysis
93
Quantitative Analysis
93
Creating a Calibration
94
Developing a Calibration Method
94
Generating the Calibration Curve
97
Analyzing Unknowns
102
CHAPTER 10: Qualitative Analysis
103
Data Analysis and Reporting
103
CHAPTER 11: Mobility
107
Functions of Mobility
107
Mobility Markers
108
Assigning Mobility Values
108
Mobility Plot
110
Demonstration: Using the Mobility Features
111
Peak Identification by Mobility
113
CHAPTER 12: Creating Reports
115
Introduction
115
Creating a Method Custom Report
116
Modifying a Report Template
116
Saving a Report as a Template
119
Saving a Report as a Default Report
120
Report Templates
120
Method Custom Report Templates
120
Sequence Custom Report Templates
120
Standard Report Templates
121
Sequence Reports
121
APPENDIX A: Additional Resources
123
32 Karat Software Online Help
123
Installation and Maintenance Guide
123
SCIEX Service
123
Other References
123
APPENDIX B: PA 800 Plus System Calculations
125
Calculations
125
CE Calculations
125
Ohm's Law
125
Corrected Migration Time
125
Corrected Area
126
Mobility
126
APPENDIX C: Understanding PDA Data
129
Overview
129
Mixed View
131
Contour Plot
132
Spectrum
132
Electropherogram
132
3D Plot
132
APPENDIX D: System Administration
135
Overview
135
APPENDIX E: Vial Incrementing
137
Introduction
137
Examples of Use
139
Example 2
142
Summary
145
APPENDIX F: Sequence Vial Report
147
Overview
147
Sequence Vial Increment Preview
147
Sequence Vial Report-Confirmed
149
Revision History
157
Advertisement
SCIEX PA 800 Plus System Maintenance Manual (86 pages)
Pharmaceutical Analysis System
Brand:
SCIEX
| Category:
Medical Equipment
| Size: 2 MB
Table of Contents
Table of Contents
3
Overview
5
Introduction
6
Install UV or PDA Detectors
7
Calibrate the PDA Detector
10
Install UV Detector Wavelength Filters
11
Integrated 488 Nm Solid-State Laser
17
Installation Requirements
17
Install the Solid-State Laser Module
17
Install the LIF Detector Filters
17
Install the Filter Housing into the Detector
19
Install the LIF Detector into the PA 800 Plus System
20
Connect the Probe to the Clamp Bar
20
LIF Detector Calibration
21
Troubleshooting Procedures
24
Capillary Cartridge
25
Rebuild a Capillary Cartridge
25
Install a Capillary Cartridge into the PA 800 Plus System
44
Universal Vials and Caps
46
Fill the Universal Vials
46
Fill the Micro Vials
47
Maintenance Procedures
49
Opening Levers, Electrodes, and the Interface Block
50
Clean Electrodes, Opening Levers, and the Interface Block
53
Coolant
54
Fiber Optics (UV and PDA Detectors)
56
Lamp
58
Instrument Care
65
LIF Care and Inspect the LIF
65
How to Clean the How to Store the
65
Maintenance
65
Lif
65
Replace the Quad-Rings
66
Replace the Fuses
67
Connect the System to a Mass
69
Spectrometer
69
Install the Capillary in the Standard
70
Cartridge
70
Ground Connection
72
CE-MS/MS Mode Cartridge Procedures
69
APPENDIX A: LIF Test MIX Calibration and Performance Tests
73
(Ccf)
73
Calibration Correction Factor
73
LIF Test MIX Calibration and Performance
73
Relative Fluorescent Units (RFU)
73
Tests
73
Applying the CCF
74
Automatic Calibration
74
Calibration Method
75
Capillaries
76
LIF Calibration for Different Dimension
76
Non-Fluorescent Solutions
76
LIF Calibration for Different Fluorescent
77
Solutions
77
Standard System Performance
77
Test
77
Troubleshooting
79
APPENDIX B: Evaluating PA 800 Plus System UV Filters
81
Filters
81
Overview
81
Revision History
85
SCIEX PA 800 Plus System Overview Manual (56 pages)
Pharmaceutical Analysis System
Brand:
SCIEX
| Category:
Analytical Instruments
| Size: 2 MB
Table of Contents
Table of Contents
3
CHAPTER 1 Safety, Notices and Labels
7
Alerts for Warning, Caution, Important, and
8
Instrument Safety Precautions
8
Moving Parts or Sharp
8
Note
8
Objects
8
Chemical Precautions
9
Safety Symbols and Labels
9
High Voltage Electric Shock Risk
9
Sharp Object Label
9
Symbol
9
General Biohazard Symbol
10
Caution, Biohazard Label
10
Class 1 Laser Caution Label
10
Rohs Notices
10
China Rohs Caution Label
10
China Rohs Environmental
11
Other Instrument Labels
11
Recycling Label (WEEE)
11
Label
11
Disposal of Devices Containing Mercury
12
Components
12
Overview
7
General Safety Information
7
CHAPTER 2 System Overview
13
Sample Handling System
15
Capillary Cartridge
17
Fluid Delivery, Power Supply, and Syringe Pump
18
High Voltage Power Supply
18
LED Indicators
18
Cartridge and Sample Cover
18
Interlocks
18
UV Detector Optics
19
The Photodiode Array (PDA) Detector
20
The Laser Induced Fluorescence (LIF) Detector
21
Laser Module
22
488 Nm Laser Module
22
Supported Applications
23
Igg Purity/Heterogeneity Assay
23
SDS Molecular Weight Analysis
23
Capillary Isoelectric Focusing (Cief) Analysis
23
Carbohydrate Analysis
23
Instrument
13
CHAPTER 3: System Procedures and Training Guide
25
Controller and Instrument Start up
25
Controller/Network Logon
25
License Key
25
PA 800 Plus Software
26
Enterprise Window
26
Instrument Start up
27
System Administration
27
Configuration
29
Online Versus Offline
30
How to Load the Cartridge and Samples
30
How to Run a Method
33
Analysis
36
Area Calculation
40
Annotations
41
Peak Identity
42
Run Multiple Methods with a Sequence
42
Viewing Reports
47
Standard Reports
47
Method Custom Reports
47
Sequence Custom Report
47
Advanced Reports
47
Suitability Reports
49
Viewing and Printing Reports
49
Maintenance
49
APPENDIX A: Specifications
51
PA 800 System
51
Computer Requirements
52
UV Detector
52
PDA Detector
53
Revision
55
Advertisement
Advertisement
Related Products
SCIEX P/ACE MDQ Plus
SCIEX UPS PSW 6 kVA - NA
SCIEX Categories
Laboratory Equipment
Portable Generator
Medical Equipment
Control Unit
Analytical Instruments
More SCIEX Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL