Sign In
Upload
Manuals
Brands
Scientific Manuals
Test Equipment
SM6030A
User Manuals: Scientific SM6030A Transformer Tester
Manuals and User Guides for Scientific SM6030A Transformer Tester. We have
1
Scientific SM6030A Transformer Tester manual available for free PDF download: Operation Manual
Scientific SM6030A Operation Manual (188 pages)
Automatiic Transformer Test System
Brand:
Scientific
| Category:
Test Equipment
| Size: 3 MB
Table of Contents
Table of Contents
2
Chapter 1 Out of Box Audit
9
To Inspect the Package
9
Power Connection
9
Fuse
9
Environment
9
Use of Test Fixture
10
Warm-Up
10
Other Features
10
Chapter 2 Introduction
11
Introduction to Front Panel
11
Introduction to Rear Panel
12
Introduction to Display Zone
13
Main Menu Keys and Corresponding Displayed
14
Disp]
14
Setup]
15
System Setup
15
Basic Operation
16
Start the Instrument
16
Chapter 3 Introduction to [DISP]
17
Meas Display
17
Test Function
17
Test Range
20
Test Frequency
21
Test Level
22
DC Bias
22
Test Speed
23
Tools
23
Use USB to Save LCR Test Results
24
Bin No. Disp
25
Comparator Function
26
Bin Count Disp
26
Param
27
Nom
27
Bin
27
High/Low
27
Count
28
Out
28
List Sweep Disp
28
Sweep Mode
29
FREQ (Hz)
30
Cp[:] D[:]
30
CMP (Compare)
30
Measure Setup
30
Trigger Mode
31
Auto Level Control Function
32
Average
32
Voltage/Current Level Monitor Function
32
Trigger Delay
33
Step Delay
33
Output Impedance
34
DCR Polarity
34
DC Resistance Range
34
DC Level
34
Deviation Test Function
35
Correction
36
Open
37
Short
38
Load
39
Load Correction Test Function
41
Cable Length Selection
41
Limit Table
41
Swap Parameter
42
Limit Modes of Compare Function
42
Set Nominal Value of Tolerance Mode
43
Comparator Function ON/OFF
44
Auxiliary bin ON/OFF
44
High/Low
45
List Sweep Setup
46
Mode
46
Test Parameter
46
Sweep Parameter Setup
47
Chapter 4 [SYSTEM] and <FILE MANAGE
48
System Setup
48
Main Func
48
Theme
48
Pass Beep
49
Fail Beep
49
Language
50
Pass Word
50
Bus Mode
50
Gpib Addr
51
Talk Only
51
Bias Src
51
Baud Rate
52
Data/Time
52
Lcr <File List
52
Setup File for Single-Group Component (*.STA)
53
U-Disk Manage Performance
54
Operation Steps for File Management
54
Chapter 5 Execute LCR Operation and some Examples
57
Correction Operation
57
Sweep Correction
57
Point-Frequency Correction
57
Correct Connection of DUT
58
Eliminate the Influence of Stray Impedance
59
Operation Example for Testing Inductance with SM6030A
60
Operation Example of Testing Capacitance by Multi-Frequency List Sweep
61
Operation Example of Load Correction
63
Chapter 6 Transformer Stand Alone Test
65
Circuit for Transformer Stand Alone Test
65
Some Parameters of Transformer
65
Capacitance Test between Transformer Windings
65
TRANS TEST SET> Interface
65
Delay
66
Bias
67
Mode
67
Setting Lx Test Conditions
68
Setting DCR Test Conditions
68
Test Frequency, Voltage and Switch
68
TRANS LIMIT SET> Interface
69
Lmt Mode
69
Parameter Column
69
TRANS MEAS DISP> Interface
69
Save Transformer Single-Group Test Result by U Disk
70
Chapter 7 Transformer Auto Scanning Test
71
Introduction to Scan Test Function
71
Install and Connect the Scanning Test System
71
Upper Panel of Scanning Box
73
Lower Panel of Scanning Box
75
HANDLER Interface
75
Timing Diagram of HANDLER Signal
75
Distribution and Connection Diagram for HANDLER
75
Example of Transformer
77
Transformer ID
77
Clear Ram
78
Transformer Pin Label
78
Handler Mode
79
Autotrig Delay
80
Pass Disp Time
81
Save Log as
81
Hdl Valid Time
82
Relay Act Time
82
Lk. Relay Dly
83
Dcr Relay Dly
83
Transformer ID
83
Primary Nums
84
Secondary Nums
84
Rescan Interval
84
Scan Disp Mode
84
Fail Rescan
85
Dcr Meas Delay
85
Dcr over Delay
85
Bias on Delay
85
Ignore Nom
85
Trigger Delay
86
Cylinder Ctrl
86
Allocate Pin to Fixture
86
Pin to Fixture
86
Pin Setup
87
Series Pin Short Setup
89
Paralell Pin Short Setup
89
TEST CONDITION> Interface
90
Frequency, Voltage, Switch and Scanning Sequence
91
Setting TURN Test Conditions
91
Setting Lx Test Conditions
94
Setting Lk Test Conditions
98
Setting CX Test Conditions
99
Setting Zx Test Conditions
101
Setting ACR Test Conditions
102
Setting DCR Test Conditions
103
Setting PS Test Conditions
103
Setting BL Test Conditions
105
Trans Scan Test
106
Display Zone
107
Function Key
108
PRI Page-Turning Function
109
File Manage
109
Operation Steps for File Manage
110
Stored File of SM6030A
112
Compatibility of Stored Files
112
Transformer Deviation-Deduction
113
Save Scan Test Results by U Disk
116
Statistic Page of Transformer Scan Test
116
Reset Statistic Count Value
117
Frequently Asked Questions and Answers in Transformer Scan Test
117
High & Low Limits
117
Measurement Item Loss
117
Measurement Interruption
117
Poor DCR Accuracy
118
Poor Lk Accuracy
118
Inaccurate Turn
118
Unstable Turn
118
Difference between the First and the Second Lx
118
Poor Stability of CX and Zx Open Test Data
119
DCR and PS Open Cannot Reach Infinite Large
119
User-Made Test Fixture
119
Use 1831-EXT1 to Make Test Fixture
119
Example of Using 1801-EXT11A(5.0)-B Pin Signal
121
Self-Check Function of Scanner Relay
121
Operation Steps for Scan Self-Check
121
Displayed Information on Screen
122
Detection Method for Relay Short
123
Relays Act Count
123
View Steps of Scan Box for <RELAYS ACT COUNT
123
Screen Display Information Description
124
Chapter 8 Performance and Test
125
Test Function
125
Parameter and Symbol
125
Test Combination
125
Mathematical Operation
125
Equivalent Mode
125
Range
125
Trigger
126
Delay Time
126
Connection Modes of Test Terminals
126
Test Speed (Frequency>=10Khz)
126
Average
126
Display Digit
126
Test Signal
126
Test Signal Frequency
126
Signal Mode
127
Test Signal Level
127
Output Impedance
127
Monitor for Test Signal Level
127
Maximum Measurement Display Range
127
DC Bias Voltage Source
128
Measurement Accuracy
128
Accuracies of │Z│,│Y│, L, C, R, X, G, B
128
Accuracy of D
128
Accuracy of Q
129
Accuracy of Θ
129
Accuracy of G
129
Accuracy of Rp
129
The Accuracy of Rs
130
Accuracy Factor
130
Accuracy of DCR
133
Lk Accuracy
133
Turns to Ratio Accuracy
134
Safety Requirement
134
Insulation Resistance
134
Insulation Intensity
134
Leakage Current
134
Electromagnetic Compatibility
134
Performance Test
135
Working Condition
135
The Used Instruments and Devices
135
Function Check
136
Test Signal Level
136
Frequency
136
Measurement Accuracy
136
Accuracy of C and D
136
Accuracy of L
136
Accuracy of Z
137
Accuracy of DCR
137
Chapter 9 Command Reference
138
Subsystem Commands for SM6030A
138
Display Subsystem Commands
138
Frequency Subsystem Commands
140
Voltage Subsystem Commands
141
Current Subsystem Commands
141
Amplitude Subsystem Commands
141
Output Resister Subsystem Commands
142
BIAS Subsystem Commands
142
Function Subsystem Commands
144
LIST Subsystem Commands
147
Aperture Subsystem Commands
151
Trigger Subsystem Commands
152
Fetch? Subsystem Commands
153
Correction Subsystem Commands
156
Comparator Subsystem Commands
162
Mass Memory Subsystem Commands
166
TRAN Subsystem Commands
167
GPIB Common Commands
173
Chapter 10 The Description for Handler (Optional)
177
Technical Description
177
The Operation Description
177
The Definition for the Signal Line
177
Electrical Feature
184
HANDLER Interface Board Circuit
185
Operation
188
Advertisement
Advertisement
Related Products
Scientific SME1190
Scientific SMO1000E
Scientific SMO2000X
Scientific SMO1002
Scientific SMO1000A-S
Scientific SMO5000X Series
Scientific SMO2000XP
Scientific SMO2000X-E
Scientific SMO1000U
Scientific SMO502ED
Scientific Categories
Power Supply
Measuring Instruments
Test Equipment
Laboratory Equipment
Portable Generator
More Scientific Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL