Sign In
Upload
Manuals
Brands
Schiedel Manuals
Fireplace Accessories
CM06 FS
Schiedel CM06 FS Manuals
Manuals and User Guides for Schiedel CM06 FS. We have
1
Schiedel CM06 FS manual available for free PDF download: Operating Manual
Schiedel CM06 FS Operating Manual (99 pages)
Brand:
Schiedel
| Category:
Fireplace Accessories
| Size: 6 MB
Table of Contents
Table of Contents
2
Contents
4
Operating Manual 90° Actusafe CMF(S)QT
5
Manual for 90-Degree Failsafe-Actuators - CMF(S)QT
5
Safety Instructions
5
Introduction
6
Functional Description of the CMF(S)QT - Failsafe Drive
7
Failsafedirection
8
Moving-Behaviour of the Actuator
9
Moving Behaviour Electrical Mode
9
Moving Behaviour Failesafe Mode
9
General Information
9
Serial Number
9
Protection Class
9
Mounting Position
9
Direction of Rotation
9
Protective Devices
9
Ambient Temperature
9
Condition on Delivery of the Actuators
10
Note (Tag)
10
Transport and Storage
10
Installation Instructions
10
Mechanical Connection
10
Mounting Position of the Control Unit
11
Electrical Connection
11
Commissioning
11
General Information
11
Manual Operation
11
Activate Manual Operation
12
Deactivate Manual Operation
12
Direction of Rotation Handwheel for Closing the Valve, Failsafe Direction „CW
13
Direction of Rotation Handwheel for Closing the Valve, Failsafe Direction „CCW
14
Required Torque on the Handwheel
15
Mechanical Default Setting, Preparation
15
Setting the End Positions
15
Setting the Mechanical End Stop
15
Adjusting of Failsafe Speed
16
Setting Procedure
17
Final Work
18
The Control Unit
18
Maintenance
19
Technical Data Failsafe Brake
20
Cm03F(S)Qt
20
Cm06F(S)Qt
20
Cm12F(S)Qt
20
Spare Parts
20
Lubricant Recommendation / Lubricant Requirements
20
Lubricant Points F(S)QT
20
Basic Lubricant Service Interval
21
Training
21
Mode of Operation F(S)QT
22
Cm03 F(S)Qt
22
Cm06 F(S)Qt
23
Operating Manual ACTUSMART CM.V1.2
24
Introduction/Notes
24
General
25
Overview
25
Serial Number and Type Label
25
Operating Mode
26
Protection Class
26
Mounting Position
26
Direction of Rotation
26
Protection Devices
27
Torque
27
Motor Temperature
27
Input Fuse, Thermal Fuse
27
Ambient Temperature
27
Delivery Condition of the Actuators
27
Information Notice (Tag)
27
Packaging, Transport and Storage
28
General
28
Storage
28
Long-Term Storage
28
Installation Instructions
29
Mechanical Connection
29
Mounting Postion of the Operating Unit
30
Electrical Connection
31
Power Supply Connection
31
Commisioning
32
General
32
Manual Operation
32
Mechanical Default Settings, Preparation
32
User Level and Permissions
33
End Limit Setting
33
End Limit OPEN
33
End Limit CLOSE
35
Final Works
36
Control Unit
36
Operating Unit
36
Display Elements
37
Graphic Display
37
LED Display
37
Operation
38
Welcome Menu
38
Operation Mode
40
Configuration
40
Configuration Example
41
Teachin
42
Parameter Menu
44
Parameter Group: End Limit
44
Parameter Group: Torque
45
Parameter Group: Speed
46
Parameter Group: Ramp (Optional)
46
Parameter Group: Control
46
Parameter Group: User Level
47
Parameter Group: Position
49
Parameter Group: Binary Inputs
50
Parameter Group: Binary Outputs
53
Parameter Group: Position Output (Optional)
57
Parameter Group: Step Mode
57
Parameter Group: Positioner (Optional)
59
Parameter Group: PID Controller (Optional)
61
Parameter Group: Bus Systems (Optional)
62
Parameter Group: Characteristic Curves (Optional)
63
Torque Characteristic
63
Speed Characteristic
64
Valve Characteristic
64
Parameter Group: Identification (Optional)
65
Parameter Group: System Parameters
65
Parameter Group: Miscellaneous
66
Default User Level Settings
68
Status Area
71
Status
71
Status - Binary Outputs
71
Status - Binary Inputs
71
Status - Analog Values
72
Status - Absolute Values
72
Status - Firmware
73
Status - Serial Number
73
Status - Meter Readings
73
History
73
Infrared Connection
74
Bluetooth Connection
74
Maintenance
75
Troubleshooting
76
History Entries
76
Fuses
78
Spare Parts
78
Lubricant Recommendation, Lubricant Requirements
78
Main Body: -25 to +60°C
78
Main Body: -40 to +60°C
78
Output Type a and Spindle Drives (Linear Actuators) -40 to +60°C
79
Basic Lubricant Service Interval
79
Training
79
Original Declaration of Incorporation of Partly Completed Machinery
80
Declaration of Conformity
81
Declaration of Conformity
82
Technical Data
83
Binary Outputs
83
Binary Inputs
83
Analog Inputs
85
Analog Output
86
Auxiliary Voltage Input and Output
86
Connections
87
Connections for Non Explosion-Proof Version
87
Connections for Explosion-Proof Version
87
Mode of Operation CM
88
Mode of Operation CM03 + QT
89
Mode of Operation CM03 + L
90
Mode of Operation CM03 + LK
91
Miscellaneous
91
Technical Data CM03
92
Standard Version CM03
92
VDC Version CM03
92
400 V Version CM03
92
Technical Data CM06
92
Standard Version CM06
92
400V Version CM06
93
Technical Data CM12
93
Standard Version CM12
93
Characteristic Curves
94
Characteristic Curves - CM03
94
Characteristic Curves - CM06
95
Characteristic Curves - CM12
96
Advertisement
Advertisement
Related Products
Schiedel CM03
Schiedel CM03 FS
Schiedel CM06
Schiedel ICID Plus
Schiedel Isokern DM 36
Schiedel Isokern DM 44
Schiedel Isokern DM 54
Schiedel Prima Smooth
Schiedel RITE-VENT ICID PLUS
Schiedel Categories
Fireplace Accessories
Fan
Industrial Equipment
Stove
Indoor Fireplace
More Schiedel Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL