Sign In
Upload
Manuals
Brands
Samson Manuals
Remote Control
trovis 5600
Samson trovis 5600 Automation System Manuals
Manuals and User Guides for Samson trovis 5600 Automation System. We have
1
Samson trovis 5600 Automation System manual available for free PDF download: Mounting And Operating Instructions
Samson trovis 5600 Mounting And Operating Instructions (128 pages)
Heating and District Heating Controller
Brand:
Samson
| Category:
Remote Control
| Size: 0.93 MB
Table of Contents
Table of Contents
3
1 Safety Instructions
7
Start-Up
7
Disposal
8
2 Operation
9
Information Menu
11
Retrieving Information
12
Operation Menu
14
Selecting the Operating Mode
15
Defining Special Times-Of-Use
16
Times-Of-Use Menu
18
Changing the Times-Of-Use
18
3 Setup Settings
21
Changing Set Points and Deactivation Values
23
Altering the Screen Contrast or Brightness
25
Changing the System Date and Time
26
Calibrating the Display
27
Cleaning the Display
28
Changing the Language Setting
28
Configuring the Controller and Changing Parameter Settings
29
Changing the System Code Number
30
Activating or Deactivating Functions
30
Setting Parameters
32
4 Manual Mode
33
5 Systems
35
6 Functions of the Heating Circuit
53
Weather-Compensated Control
53
Gradient Characteristic
54
Four-Point Characteristic
57
Fixed Set Point Control
58
Underfloor Heating/Drying of Jointless Floors
59
Deactivation Based on the Outdoor Temperature
60
HC Deactivation Value (Day)
60
HC Deactivation Value (Night)
60
Outdoor Temperature for Continuous Rated Operation (Day)
61
Summer Mode
61
Delayed Outdoor Temperature Adaptation
62
Remote Operation
62
Optimization
63
Optimization Based on Outdoor Temperature
63
Optimization Based on Room Temperature
63
Optimization Based on Outdoor and Room Temperature
64
Flash Adaptation
65
Flash Adaptation Without Outdoor Sensor (Based on Room Temperature)
66
Adaptation
66
Set Point Correction Using a 0 to 10 V Signal
67
7 Functions of the DHW Circuit
68
DHW Heating in the Storage Tank System
68
DHW Heating in the Storage Tank Charging System
70
Circulation Return Flow in Heat Exchanger
73
DHW Heating in Instantaneous Heating System
74
Intermediate Heating Operation
75
Parallel Pump Operation
75
Circulation Pump Operation During Storage Tank Charging
76
Priority Operation
76
Reverse Control
76
Set-Back Operation
77
Forced Charging of the DHW Storage Tank
78
Thermal Disinfection of the DHW Storage Tank
78
8 System-Wide Functions
80
Automatic Summer Time/Winter Time Switchover
80
Frost Protection
80
Forced Operation of the Pumps
81
Return Flow Temperature Limitation
81
Condensate Accumulation Control
82
Three-Step Control
83
On/Off Control
83
Continuous Control
84
Unlocking a Controller/Control Loop 1 over the Binary Input
84
Processing an External Demand
86
Processing an External Demand with a Binary Signal
86
Processing an External Demand with a 0 to 10 V Signal
87
Demand Requested with a 0 to 10 V Signal
87
Forwarding the Measured Outdoor Temperature
87
Locking the Manual Level
88
9 Operational Faults
89
Sensor Failure
90
Temperature Monitoring
90
Collective Fault Alarm
91
10 Installation
92
11 Electrical Connection
94
12 Interfaces
98
Memory Pen
99
Trovis-View
99
13 Appendix
100
Configuration Levels
100
Parameter Levels
111
Sensor Resistance Tables
115
Technical Data
116
Customer Data
117
Index
122
Advertisement
Advertisement
Related Products
Samson trovis 5570
Samson trovis 5610
Samson Hartke Systems 5000
Samson STAGE 5H
Samson 5006-1
Samson TROVIS 5757-7
Samson TROVIS 5724-810
Samson TROVIS 5725-810
Samson 5827
Samson TROVIS 5578-E
Samson Categories
Controller
Control Unit
Microphone
Valve Positioners
Speakers
More Samson Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL