Sign In
Upload
Manuals
Brands
RMS Mors Smitt Manuals
Measuring Instruments
1S24
RMS Mors Smitt 1S24 Manuals
Manuals and User Guides for RMS Mors Smitt 1S24. We have
1
RMS Mors Smitt 1S24 manual available for free PDF download: User Manual
RMS Mors Smitt 1S24 User Manual (103 pages)
Arc Fault Monitoring System, Advanced Protection Devices
Brand:
RMS Mors Smitt
| Category:
Measuring Instruments
| Size: 5 MB
Table of Contents
Table of Contents
5
Sensor Installation
8
1S30 Sensors
8
Sensor Placement
10
Sensor Mounting
10
Example Sensor Placement
11
1S40 Linear Sensors
15
1S40 Linear Sensor Assembly
17
1S40 Linear Sensor Compartment Fixing
18
Scheme Wiring
19
1S24 Connection Diagrams
19
Linear Sensor Connections
21
Example Schematic - Direct Arc Trip Only Application
22
Example Schematic - Current Checked Arc Trip Application
23
Terminal Layout and Module Dimensions
24
Surface or Din Rail Mounting
24
Horizontal or Vertical Flush Mounting
27
Custom Labels
30
Communications
31
Physical Connections
31
IEC61850 Communication Topologies
32
IP Addressing
33
1S24 Arc Fault Monitor Configuration
34
Web Browser Session
34
Relay Build
36
IP Configuration
36
Arc Configuration
37
State
38
Trip 1
38
Trip 2
38
Zone
38
Linear Sensor Configuration
39
Arc Status
40
State
40
Flag
40
Count
41
Summary of 1S24 SARC Configuration
41
Example IEC61850 Substation Configuration
42
Application Example
42
Arc Fault Scheme
43
1S24 SARC Allocation
45
Protection Zone Tripping
45
1S24 Source Arc Fault Detector Points
46
7SR22 Single Point Input GGIO Allocation
46
Creating an IEC61850 Project
46
Populating Ieds in the IEC 61850 Project
49
System Configuration - Network View
55
System Configuration - Link View
58
Creating the 1S24 .CID File
62
1S24 IEC61850 Configuration
63
The .CID File
63
FTP 1S24.CID File
63
Rebooting the 1S24 with the New 1S24.CID File
65
Subscribing Reyrolle 7SR22 IED Configuration
69
Logic Configuration
69
User Output Allocation
69
Current Check Logic
70
Binary Output Allocation for Circuit Breaker Tripping
71
Device Synchronization
71
Monitor Indications
72
Front Layout
72
Power up
72
System Status
73
Service Alarm
73
Arc Sensor Indicators
74
Arc Sensor Circuit Supervision
74
Arc Trip
74
Global Arc Block
74
Flag Reset
75
Reboot
75
Reset to Factory Default
76
Firmware Update
77
Introduction
77
Firmware Package
77
Trouble Shooting
79
License File Not Valid or Present
79
Invalid IP Address Specified in ICD File
81
System Status
82
Commissioning
83
Commissioning Preliminaries
83
Site Commissioning Verification Checklist
84
System Power up
84
Sensor Failure Alarm Verification
85
Arc Trip Testing
85
Sensor Failure Alarm Trouble Shooting
86
ARC Trip Trouble Shooting
87
General Ethernet Communications Trouble Shooting
87
IEC61850 GOOSE Message Trouble Shooting
88
Interpreting VX Auxiliary Supply or Relay Healthy Indications
88
Using IED SCOUT IEC61850 GOOSE Message Trouble Shooting
90