Sign In
Upload
Manuals
Brands
Riello Manuals
Burner
C9342400
Riello C9342400 Manuals
Manuals and User Guides for Riello C9342400. We have
1
Riello C9342400 manual available for free PDF download: Installation, Use And Maintenance Instructions
Riello C9342400 Installation, Use And Maintenance Instructions (40 pages)
Forced draught gas burners
Brand:
Riello
| Category:
Burner
| Size: 6.07 MB
Table of Contents
Table of Contents
3
Information and General Instructions
5
Information about the Instruction Manual
5
Introduction
5
General Dangers
5
Other Symbols
5
Guarantee and Responsibility
6
Owner's Responsibility
6
Safety and Prevention
7
Introduction
7
Personnel Training
7
Technical Description of the Burner
8
Technical Data
8
Electrical Data
8
Burner Models Designation
9
Burner Equipment
9
Burner Dimensions
10
Firing Rates
10
Procedure to Refer Burner Operating Condition at an Altitude And/Or at a Combustion Supporter Air Temperature Different to the Standard Values (328 Ft above Sea Level, 68 °F)
11
Minimum Furnace Dimensions
12
Commercial Boilers
12
Burner Description
13
Control Box for the Air/Fuel Ratio (LMV37.4
14
Actuators (SQM33.5
17
Installation
18
Notes on Safety for the Installation
18
Handling
18
Preliminary Checks
18
Operation Position
18
Preparing the Boiler
19
Boiler Plate
19
Securing the Burner to the Boiler
19
Electrode Positioning
20
Combustion Head Calibration
20
Adjustment of the Combustion Head
21
Air Adjustment
21
Gas Adjustment
21
Burner Refitting
22
Gas Supply
23
Gas Train
23
Gas Feeding Line
23
Gas Supply Pressure
24
Electrical Wiring
25
Thermal Relay Calibration
26
Electro-Mechanical Thermal Relay
26
Electronic Thermal Relay
26
Motor Connection at 208-230 or 460V
27
Motor Connection at 575V
27
Reversible Direction
27
Start-Up, Calibration and Operation of the Burner
28
Notes on Safety for the First Start-Up
28
Operations before Start-Up
28
Burner Start-Up
28
Adjusting Gas/Air Delivery
29
Final Calibration of the Pressure Switches
29
Air Pressure Switch
29
Maximum Gas Pressure Switch
29
Minimum Gas Pressure Switch
30
Flame Signal Measurement
30
Final Checks (with the Burner Working)
30
Maintenance
31
Notes on Safety for the Maintenance
31
Maintenance Programme
31
Maintenance Frequency
31
Safety Test - with Gas Ball Valve Closed
31
Checking and Cleaning
31
Safety Components
32
Opening the Burner
33
Closing the Burner
33
A Appendix - Spare Parts
34
B Appendix - Accessories
37
Appendix - Burner Start up Report
38
Advertisement
Advertisement
Related Products
Riello C9343710
Riello C9342410
Riello C9343400
Riello C9343410
Riello C9343401
Riello C9341400
Riello C9327710
Riello C9352410
Riello C9336410
Riello C9335710
Riello Categories
Burner
Boiler
Indoor Fireplace
UPS
Water Heater
More Riello Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL