Manuals and User Guides for Quantel Medical AXIS NANO. We have
1
Quantel Medical AXIS NANO manual available for free PDF download: Service Manual
Quantel Medical AXIS NANO Service Manual (45 pages)
High Precision Biometer
Brand:
Quantel Medical
| Category:
Medical Equipment
| Size: 1.11 MB
Table of Contents
Table of Contents
3
1 Introduction
5
2 Service Manual Terms and Safety Symbols
5
3 Warnings
5
4 Technical Specifications
8
Classification
8
Electrical Requirements
8
Compliance
8
Dimensions
9
Environmental Conditions
9
Computer Minimum Requirements
9
Block Diagram
10
5 Accessories and Spare Parts
10
External View
10
Spare Parts
11
6 Markings
12
7 Disassembling
13
Probe Holder Removal
13
Cover Removal
13
Acquisition Board
14
8 Location and Connector Pin Description
15
9 Database Information and Backup
16
Automatic Backup (Only Available from Version over 1.03)
16
Database Information
16
Manual Database Backup and Restoration
17
To Manually Make a Database Backup
17
To Manually Restore the Database on the Axis Nano Unit
17
10 Software Installation
18
Software Compatibilities
18
Software and Operating System Compatibilities
18
Software Upgrade and Compatibilities
18
Software and Screen Resolution Compatibilities
18
Axis Nano Software Behavior with UAC on or UAC off
19
Installation Warnings and Cautions
20
Upgrade Procedure
20
Uninstalling Previous Software Version
20
In Case the Axis Nano Software Version 1.04 Cannot be Uninstalled
21
Installation Procedure
21
11 Hardware Installation
24
12 USB Driver Installation
25
13 AXIS NANO Software Display & Adustments
26
Navigation Properties Setup with Windows ® Eight (8.1)
26
Adjust Magnifier Tool
27
Suppressing the Access to Switch « User Account
27
14 AXIS NANO Setup
27
15 Hidden Screen
29
Accessing the Hidden Screen
29
Hidden Screen Functions
30
Zero" Field and "Position of Marker #1 in Contact
30
Retina Slope Test
30
Biometry Default Mode
31
Field "D2/Low Dyn
31
Keycode
31
Main Icons Displayed by Default
31
16 Probes Calibration
32
Calibration Check
32
Calibration Adjustment
34
Using the Hidden Screen to Reset the " Position of Marker #1 in Contact " to Zero
36
17 AXIS NANO - no Top most Mode
37
18 Operating System Reinstallation Procedure
38
19 Care of the Unit
41
20 Care of the Different Probes
41
21 Computer Battery Exchange
41
22 HIPAA Compliance
42
Security Awareness and Training
42
Contingency Plan
43
Access Controls
43
Audit Controls
44
Integrity
45
Person or Entity Authentication
45
Transmission Security
45
Advertisement
Advertisement
Related Products
Quantel Medical Axis II PR
Quantel Medical Aviso
Quantel Medical 532NM
Quantel Medical 577NM
Quantel Medical 660NM
Quantel Medical 810 NM
Quantel Medical Pocket II E PCK2 MT AN
Quantel Medical Categories
Medical Equipment
Measuring Instruments
More Quantel Medical Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL