Manuals and User Guides for ProtoCessor ProtoNode RER. We have
1
ProtoCessor ProtoNode RER manual available for free PDF download: Startup Manual
ProtoCessor ProtoNode RER Startup Manual (38 pages)
Brand:
ProtoCessor
| Category:
Gateway
| Size: 2 MB
Table of Contents
Table of Contents
3
1 Introduction
5
BTL Mark - Bacnet Testing Laboratory
5
Lonmark Certification
5
2 Bacnet/Lonworks Setup for Protonode RER/LER
6
Installation Steps for the Customer
6
Record Identification Data
6
Configure the DIP Switches
6
Setting the Node/ID Device Instance (DIP Switch A0 - A7) for Bacnet MS/TP, Bacnet/Ip, and Metasys N2
6
Setting the Serial Baud Rate (DIP Switch B0 - B3) for Bacnet MS/TP and Metasys N2 Protonodes
7
Using S0 - S3 Bank of DIP Switches to Select and Load Configuration Files for ENVI and Love Controller
7
Figure 1: A0 - A7 DIP Switches
7
Figure 2: B0 - B3 DIP Switches
7
Figure 3: S0 - S3 DIP Switches
7
3 Interfacing the Protonode to ENVI and Love Controller
10
Protonode RER and LER Component Layout with the Cover Removed
10
Figure 4: Protonode Bacnet RER N34 (Top) and Protonode LER N35 (Bottom)
10
Wiring Connections to Protonode RER and LER for the ENVI and Love Controller
11
Figure 5: Pin Outs for the Envi's Modbus RS-485 Port and Power to the Protonode
11
Figure 6: Pin Outs for the Love's Modbus RS-485 Port and Power to the Protonode
11
3.2.2 Biasing the Modbus RS-485 Network
12
Connecting ENVI Modbus RTU Boilers to the Protonode's RS-485
12
Figure 7: Wiring Diagram for the Evni's Modbus RTU RS-485 to the Protonode's RS-485 Port
12
3.2.3 End of Line Termination Switch for the Modbus RS-485 Port on the Protonode
13
Figure 8: Modbus RS-485 Biasing Switch on the Protonode N34 (Left) and Protonode N35 (Left)
13
Figure 9: Modbus RS-485 End-Of-Line Termination Switch on Protonode N34 (Left) and Protonode N35 (Right)
13
Wiring the Protonode RER to RS-485 Field Protocol
14
Figure 10: Connection from Protonode to RS-485 BMS Field Protocol -Bacnet MS/TP or Metasys N2
14
Figure 11: End-Of-Line Termination on from Protonode to RS-485 BMS Field Protocol
14
Wiring the Protonode LER Field Port to a Lonworks Network
15
Power-Up the Protonode RER or LER
15
Figure 10: Protonode LER Lonworks FFT-10 2 Wire Screw Terminal
15
Figure 13: Protonode Power Pin Outs
15
4 Commissioning the Protonode LER on a Lonworks Network
16
4.1.1 Instructions to Upload XIF File from the Protonode LER Using FS GUI Web Server
16
Figure 14: Sample of Fserver.xif File Being Generated
17
5 Connect the Protonode's Web GUI to Setup IP Address for Bacnet/Ip or Modbus TCP
18
Connect the PC to the Protonode Via the Ethernet Port
18
Figure 15: Ethernet Port Location of Protonode
18
Use the Protonode Web GUI to Connect to the Protonode
19
Set IP Address for Bacnet/Ip or Modbus TCP Via GUI
19
Figure 16: FST Web GUI Screen
19
Figure 17: FST Web GUI IP Address Settings Screen
20
6 Chipkin Automation's CAS Bacnet Explorer for Validating the Protonode in the Field on a Bacnet MS/TP or Bacnet/Ip Network
21
Downloading Chipkin Automation's CAS Explorer and Requesting an Activation Key
21
CAS Bacnet Setup
22
CAS Bacnet MS/TP Setup
22
CAS Bacnet Bacnet/Ip Setup
22
Appendix A. Troubleshooting Tips
23
Appendix A.1. Check Wiring and Settings
23
Appendix A.2. Take Log with Our Fieldserver Utilities
23
Appendix A.3. LED Diagnostics for Modbus RTU Communications between the Protonode and the ENVI and the Love Controller
26
A.3.1 Protonode RER and LER Leds
26
Appendix B. Vendor Information
27
Appendix B.1. ENVI and Love Controller Modbus RTU COM Settings
27
Appendix B.2. ENVI Modbus RTU Mappings to Bacnet MS/TP, Bacnet IP, Metasys and Lonworks
27
Appendix B.3. Love Controller Modbus RTU Mappings to Bacnet MS/TP, Bacnet IP, Metasys N2
28
Appendix B.4. DIP Switch Settings for ENVI and Love Controllers to Support Metasys N2 and Modbus TCP and Bacnet for the Love Controller
29
Appendix B.5. Address DIP Switch Settings
31
Appendix C. Reference
37
Appendix C.1. Specifications
37
Appendix C.1.1. Compliance with UL Regulations
37
Appendix D. Limited 2 Year Warranty
38
Advertisement
Advertisement
Related Products
ProtoCessor ProtoNode LER
ProtoCessor FieldServer SATEC ProtoNode FPC-N34
ProtoCessor FieldServer SATEC ProtoNode FPC-N35
ProtoCessor Categories
Gateway
More ProtoCessor Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL