ProtoCessor FieldServer SATEC ProtoNode FPC-N35 Manuals
Manuals and User Guides for ProtoCessor FieldServer SATEC ProtoNode FPC-N35. We have
1
ProtoCessor FieldServer SATEC ProtoNode FPC-N35 manual available for free PDF download: Startup Manual
ProtoCessor FieldServer SATEC ProtoNode FPC-N35 Startup Manual (41 pages)
For Interfacing Satec Products: BFM136 and EM133 To Building Automation Systems: BACnet MS/TP, BACnet/IP, Modbus/TCP, Metasys N2 and LonWorks
Brand:
ProtoCessor
| Category:
Gateway
| Size: 2 MB
Table of Contents
Table of Contents
5
Introduction
7
Protonode Gateway
7
Satec's Devices and Point Count Available
7
Figure 1: Modbus Registers
7
Bacnet/Lonworks Setup for Protocessor Protonode FPC-N34/FPC-N35
8
Record Identification Data
8
Configuring Device Communications
8
2.2.1 Set Modbus COM Setting on All of the Devices Connected to the Protonode
8
2.2.2 Set Modbus RTU Node-ID for each of the Devices Attached to the Protonode
8
Figure 2: Protocessor Part Numbers
8
Figure 3: Modbus RTU COM Settings
8
Selecting the Desired Field Protocol
9
Figure 4: S Bank DIP Switches
9
Setting the MAC Address, Device Instance and Baud Rate
10
2.4.1 Bacnet MS/TP (FPC-N34): Setting the MAC Address Bacnet Network
10
Figure 5: MAC Address DIP Switches
10
Bacnet MS/TP and Bacnet/Ip (FPC-N34): Setting the Device Instance (Node-ID)
11
2.4.3 Metasys N2 or Modbus/Tcp (FPC-N34): Setting the Node-ID
11
2.4.4 Bacnet MS/TP (FPC-N34): Setting the Baud Rate
12
Figure 6: Baud Rate DIP Switches
12
Figure 7: Baud Rate
12
Interfacing Protonode to Devices
13
Protonode FPC-N34 and FPC-N35 Showing Connection Ports
13
Figure 8: Protonode Bacnet FPC-N34 (Upper) and Protonode FPC-N35 (Lower)
13
Device Connections to Protonode
14
Figure 9: Power and RS-485 Connections
14
3.2.1 Biasing the Modbus RS-485 Network
15
Figure 10: Modbus RS-485 Biasing Switch on the Protonode N34 (Left) and Protonode N35 (Right)
15
3.2.2 End of Line Termination Switch for the Modbus RS -485 Port on the Protonode
16
Figure 11: Modbus RS-485 End-Of-Line Termination Switch on the Protonode N34 (Left) and
16
Bacnet MS/TP or Metasys N2 (FPC-N34): Wiring Field Port to RS-485 Network
17
Lonworks (FPC-N35): Wiring Field Port to Lonworks Network
17
Figure 12: Connection from Protonode to RS-485 Field Network
17
Figure 13: RS-485 EOL Switch
17
Figure 14: Lonworks Terminal
17
Connecting Power to Protonode
18
Figure 15: Required Current Draw for the Protonode
18
Figure 16: Power Connections
18
Use Protonode's Web Configurator to Select Device Profiles
19
Connect the PC to Protonode Via the Ethernet Port
19
Figure 17: Ethernet Port Location
19
Connecting to Protonode's Web Configurator
20
4.2.1 Selecting Profiles for Devices Connected to Protonode
20
Figure 18: Web Configurator Showing no Active Profiles
20
Figure 19: Web Configurator Showing Available Profiles for Selection
21
Figure 20: Web Configurator Showing an Active Profile Addition
21
Bacnet MS/TP and Bacnet/Ip: Setting Node_Offset to Assign Specific Device Instances
22
Accessing the FST Web GUI from the Web Configurator
23
Figure 20: Web Configurator Screen with Active Profiles
23
Bacnet/Ip and Modbus TCP: Setting IP Address for Field Network
24
Figure 21: Changing IP Address Via FST Web GUI
24
Lonworks (FPC-N35): Commissioning Protonode on a Lonworks Network
25
Commissioning Protonode FPC-N35 on a Lonworks Network
25
Instructions to Upload XIF File from Protonode FPC-N35 Using Fieldserver GUI Web Server
25
Figure 23: Lonworks Service Pin Location
25
Figure 24: Sample of Fserver.xif File Being Generated
26
CAS Bacnet Explorer for Validating Protonode in the Field
27
Downloading the CAS Explorer and Requesting an Activation Key
27
Figure 25: Downloading the CAS Explorer
27
Figure 26: Requesting CAS Activation Key
27
CAS Bacnet Setup
28
CAS Bacnet MS/TP Setup
28
CAS Bacnet Bacnet/Ip Setup
28
Appendix A. Troubleshooting
29
Appendix A.1. Check Wiring and Settings
29
Appendix A.2. Take Diagnostic Capture with the Fieldserver Utilities
29
Figure 27: Ethernet Port Location
29
Appendix A.3. if There Is more than 1 Protonode on the same Bacnet/Ip Network, Change Network Number
32
Appendix A.4. LED Diagnostics for Modbus RTU Communications between Protonode and Devices
32
Figure 28: Web Configurator Showing Setting the Network Number for Bacnet/Ip
32
Figure 29: Diagnostic Leds
32
Appendix B. Vendor Information - Satec
33
Appendix B.1. BFM136 Modbus RTU Mappings to Bacnet MS/TP, Bacnet/Ip, Metasys N2 and Lonworks
33
Appendix B.2. EM133 Modbus RTU Mappings to Bacnet MS/TP, Bacnet/Ip, Metasys N2 and Lonworks
34
Appendix C. MAC Address DIP Switch Settings
37
Appendix C.1. MAC Address DIP Switch Settings
37
Appendix D. Reference
40
Appendix D.1. Specifications
40
Appendix D.1.1. Compliance with UL Regulations
40
Figure 30: Specifications
40
Appendix E. Limited 2 Year Warranty
41
Advertisement