Sign In
Upload
Manuals
Brands
Protec Manuals
Medical Equipment
COMPACT 2 NDT
Protec COMPACT 2 NDT Manuals
Manuals and User Guides for Protec COMPACT 2 NDT. We have
1
Protec COMPACT 2 NDT manual available for free PDF download: User Manual
Protec COMPACT 2 NDT User Manual (65 pages)
Automated X-ray film processor
Brand:
Protec
| Category:
Medical Equipment
| Size: 2 MB
Table of Contents
Table of Contents
3
Document Effectivity
7
General Notes
8
Mechanical - Electric Warning
8
To the User
8
1 Product Description
9
Introduction
9
Description
9
Installation
9
Product Specific Characteristics
9
Intended Use
9
Indications, Contraindications
10
Intended User Group
10
Conformity
10
2 Safety Instructions
11
General Safety Notice
12
Requirements for Operation
12
Operating of the Radiographic System
12
Operating Type
12
Operating Personnel
13
Ventilation
13
Interaction with External Devices
13
Electromagnetic Environment and the Influence of Devices
13
3 Installation
14
Requirements for Installation
14
Transport
14
Installation of Processor
16
Levelling of Processor
16
Connecting the Processor
17
Water Connection
17
Hose Connection
18
Initial Operation
19
Test Run
19
Fill Processor with Chemicals
19
Mode of Operation
19
Automatic Filling and Heating
19
Stand-By Mode
19
Film Registration
19
Automatic Replenishment
19
4 Control Elements and Device Displays
20
Control Elements and Device Displays Standard
20
5 Handling / Operation
21
Operation
21
Before Use
21
Working Procedure
21
After Work
21
Stand-By Mode
22
Function of the Automated X-Ray Film Processor
22
Switching on the Machine
22
Automatic Mode
22
Anti-Crystallization Function
23
Time Replenishment (Anti-Oxidation Function, Flood Replenishment)
23
Setting off the Time Replenishment
23
Working Parameters
23
Display Working Parameters
23
Setting Working Parameters
23
Processing Time
23
Developer Temperature
24
Dryer Temperature
25
Replenishment Time
25
Dimmer Function of Display
26
Setting the Intensity of the Display
26
Machine Cover Safety Disconnection
26
Auto Fill Function
26
Starting up the Auto Fill Function
26
Manual Cancellation of the Auto Fill Function
26
Manual Mode
26
Switching to Manual Mode
26
Switching Back to Automatic Mode
26
Manual Starting and Stopping the Film Transport
27
Manual Replenishment
27
Use of Memory Function
27
Store Processing Parameters
27
Recall Processing Parameters
27
To Leave Memory Mode Without Change
27
Lock Function
27
Activating and De-Activating of the Input Lock
27
Stop Film Transport
28
Infrared Sensitive Materials
28
Automatic Cooling Function
28
Removal and Installation of Dryer Rack (Two-Parts)
29
Removal
29
Installation
30
Problems and Solutions
30
Advice on Film Defects
30
Films Do Not Have Enough Density
30
Too High a Density
30
Films will Not Dry
30
Film Has a Yellow-Green Surface
30
Scratches, Pressure Marks, Dirt on Film
30
Cloudy Film
30
Advice on Machine Errors
31
Machine Does Not Switch on
31
Rinsing Water Does Not Flow
31
Replenishment Rate too High
31
Replenishment Rate too Low
31
Replenishment Pump Does Not Pump
31
Water Tank Overflows
31
The Film Does Not Transport Correctly
31
Film Cannot be Fed, the Display Shows „E1
31
Film Is in the Infeed and Nothing Happens
31
Error Messages
32
6 Safety and Maintenance
33
Introduction
33
Cleaning and Disinfection
33
Cleaning
33
Daily Care
33
Weekly Care
34
Thorough Cleaning
34
Before You Go on Holiday or Longer than 2 Weeks Not Use
35
Check-Up and Maintenance
35
Recommended Maintenance Work
35
Maintenance
36
Maintenance Protocol
37
Warranty
38
Product Life Time
38
Further Information
38
Disposal
38
7 Trouble Shooting
39
Algae
39
Excessive Algae Growth in Water Tank
39
General
39
Mains Switch "ON" - no Function
39
No Display but Circulation Pumps Run
39
Drive
39
Machine Does Not Start Automatically
39
Machine Doesn't Stop Automatically
39
Drive Motor Does Not Run
40
Display Shows Error Message "E2
40
Baths
40
No Circulation in Bath
40
Developer Bath Temperature Is Not Reached
40
Developer Bath Temperature Is Higher than the Set Temperature, Display Shows Two Crossbars, Developer Temperature Button Blinks
40
Calibration of Bath Temperature / Actual Bath Temperature Is Different from Displayed Value
40
Calibration Process
40
Film Defects
41
Films will Not Dry
41
The Film Does Not Transport Correctly
41
Scratches, Pressure Marks, Dirt on Film
41
Replenishment
41
Replenishment Pump Does Not Work or Works Insufficiently
41
Dryer
41
Display Shows Error Message "E4
41
Dryer Ventilation Does Not Function, no Water Inflow When Water Cock Opened
41
Developer Bath Temperature too High or too Low
42
Dryer Ventilation Is too Weak
42
Dryer Temperature Cannot be Reached
42
Dryer Temperature Display Exceeds the Set Value
42
Dryer Temperature Cannot be Reached or Is too High (Display Shows Values Approx. 30 °C and 75 °C)
42
Water
42
Rinsing Water Does Not Flow
42
Water Tank Overflows
42
8 Spare Parts and Schematics
43
Spare Parts
43
Tips and Tricks
48
Removal of Control PCB
48
Adjusting the Software - Sub-Versions
48
Stop Start-Cycle
48
Display of Machine Information
48
Schematics
49
9 Power Supply
59
Electrical Connections
59
System Protection
59
Power Consumption
59
10 Technical Specifications
60
Protection Art and Protection Class
61
Environmental
61
Environmental Conditions During Operation
61
Environmental Conditions for Shipping and Storage
61
11 Description of Symbols, Labels and Abbreviations
62
Symbols
62
Identification Label
63
Labels
63
Position Symbols and Labels
65
Abbreviations
65
Advertisement
Advertisement
Related Products
Protec OPTIMAX 2010 Mammo
Protec COMPACT 2
Protec COMPACT 2 Mammo
Protec CirrusPro 200
Protec CirrusPro 200D+
Protec CirrusPro 200DSC+
Protec OPTIMAX 2010 NDT
Protec RAPIXX 2530V1V Wifi
Protec RAPIXX 2530V2V Wifi
Protec COMPACT2 SX 2
Protec Categories
Medical Equipment
Diagnostic Equipment
Control Panel
Security Sensors
Fire Alarms
More Protec Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL