Sign In
Upload
Manuals
Brands
PRECISION DIGITAL Manuals
Measuring Instruments
ProVu PD6100-7H5
PRECISION DIGITAL ProVu PD6100-7H5 Meter Manuals
Manuals and User Guides for PRECISION DIGITAL ProVu PD6100-7H5 Meter. We have
1
PRECISION DIGITAL ProVu PD6100-7H5 Meter manual available for free PDF download: Instruction Manual
PRECISION DIGITAL ProVu PD6100-7H5 Instruction Manual (56 pages)
Strain Gauge, Load Cell & mV Meter
Brand:
PRECISION DIGITAL
| Category:
Measuring Instruments
| Size: 2 MB
Table of Contents
Table of Contents
3
Table of Figures
4
Introduction
4
Ordering Information
5
Specifications
6
General
6
Strain Gauge Input
7
Relays
7
Isolated 4-20 Ma Transmitter Output
8
Modbus ® RTU Serial Communications
8
Meterview Pro
8
Compliance Information
9
Electromagnetic Compatibility
9
Safety
9
Figure 2. Panel Mounting Details
10
Figure 1. 1/8 DIN Panel Cutout Dimensions
10
Mounting Dimensions
11
Sensor Excitation Voltage Selection (EX+, EX-)
11
Safety Information
10
Installation
10
Panel Mounting Instructions
10
Unpacking
10
Figure 3. Meter Dimensions - Side View
11
Figure 4. Meter Dimensions - Top View
11
Figure 5. Sensor Excitation Voltage Selection
11
Figure 6. Connector Labeling for Fully Loaded
12
Figure 7. Power Connections
12
Figure 8. Strain Gauge Configuration Switch
13
Signal Connections
13
Switch Configuration
13
Connections
12
Connectors Labeling
12
Power Connections
12
Figure 10. Strain Gauge Powered by External Supply
14
Figure 9. Strain Gauge Powered by Internal Supply
14
Figure 12. MV Transducer Input Connections
15
Figure 14. Relay Connections
16
Figure 16. Low Voltage DC Loads Protection
16
Figure 17. 4-20 Ma Output Connections
17
Figure 18. F4 Digital Input Connections
17
External Relays & Digital I/O Connections
18
Figure 19. Expansion Modules & DIN Rail Mounting Kit
18
Figure 20. External Relays Module Connections
18
Figure 21. Digital I/O Module Connections
18
Figure 22. Interlock Connections
18
Interlock Relay Feature
18
Figure 11. Multiple Strain Gauges Connected through Junction Box
15
Figure 15. AC and DC Loads Protection
16
Modbus RTU Serial Communications
16
Relay Connections
16
Switching Inductive Loads
16
4-20 Ma Output Connections
17
Analog Output Power Supply
17
F4 Digital Input Connections
17
Figure 13. Shunt Resistor
15
Shunt Calibration
15
Setup and Programming
19
Front Panel Buttons and Status LED Indicators
19
Meterview ® Pro Software
20
Meterview Pro Installation
20
Display Functions & Messages
21
Main Menu
23
Setting Numeric Values
23
Setting up the Meter (Setup)
24
Setting the Input Signal (Input)
25
Setting the Input Units (Units)
26
Setting the Input Units or Custom Tags (Units)
27
Programming the Meter (Prog)
28
Calibrating the Meter with Strain Gauge/Load Cell (Cal)
28
Setting the Display Parameter & Intensity (Dsplay)
30
Setting the Relay Operation (Relay)
31
Setting the Relay Action
32
Programming Set and Reset Points
33
Setting Fail-Safe Operation
33
Programming Time Delay
33
Relay and Alarm Operation Diagrams
33
High Alarm Operation (Set > Reset)
33
Low Alarm Operation (Set < Reset)
33
High Alarm with Fail-Safe Operation (Set > Reset)
34
Low Alarm with Fail-Safe Operation (Set < Reset)
34
Pump Alternation Control Operation
34
Relay Sampling Operation
35
Time Delay Operation
35
Relay Operation Details
36
Overview
36
Relays Auto Initialization
36
Fail-Safe Operation
36
Front Panel Leds
36
Latching and Non-Latching Relay Operation
37
Non-Latching Relay (Auto)
37
Non-Latching Relay (A-Man)
37
Latching Relay (Latch)
37
Latching Relay (Lt-Clr)
37
Acknowledging Relays
38
Pump Alternation Control Applications (Altern)
38
Figure 23. Acknowledge Relays with Digital Input
38
Scaling the 4-20 Ma Analog Output (Aout)
40
Setting up the Interlock Relay (Force On) Feature
40
Setting up the Password (Pass)
41
Protecting or Locking the Meter
41
Making Changes to a Password Protected Meter
41
Disabling Password Protection
41
Control Menu (Contrl)
42
Reset Menu (Reset)
42
Tare Menu (Tare)
42
Tare Functionality (Tare)
42
Advanced Features Menu
43
Advanced Features Menu & Display Messages
43
Noise Filter (Filter)
44
Noise Filter Bypass (Bypass)
44
Rounding Feature (Round)
44
Modbus RTU Serial Communications (Serial)
45
Select Menu (Select)
45
Signal Input Conditioning (Functn)
45
Auto-Zero (Auto 0)
46
Low Cutoff (Cutoff)
46
Analog Output Programming (Aoutpr)
46
Programmable Function Keys User Menu ( )
47
Internal Source Calibration (ICAL)
48
Error Message (Error)
49
Meter Operation
50
Front Panel Buttons Operation
50
Function Keys Operation
50
Maximum/Minimum Readings
51
Troubleshooting
52
Diagnostics Menu (Diag)
52
Determining Software Version
52
Reset Meter to Factory Defaults
52
Factory Defaults & User Settings
53
Troubleshooting Tips (Including FAULT & ERROR Messages)
54
EU Declaration of Conformity
55
Advertisement
Advertisement
Related Products
PRECISION DIGITAL ProVu PD6100-7H2
PRECISION DIGITAL ProVu PD6100-7H0
PRECISION DIGITAL ProVu PD6100-7H4
PRECISION DIGITAL ProVu PD6100-7H3
PRECISION DIGITAL ProVu PD6100-7H7
PRECISION DIGITAL ProVu PD6100-7R2
PRECISION DIGITAL ProVu PD6100-7R4
PRECISION DIGITAL ProVu PD6100-7R0
PRECISION DIGITAL ProVu PD6100-7R7
PRECISION DIGITAL ProVu PD6100-7R5
PRECISION DIGITAL Categories
Measuring Instruments
Controller
Monitor
Scanner
Network Hardware
More PRECISION DIGITAL Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL