Manuals and User Guides for PRECISION DIGITAL PD6310-WM. We have
1
PRECISION DIGITAL PD6310-WM manual available for free PDF download: Instruction Manual
PRECISION DIGITAL PD6310-WM Instruction Manual (58 pages)
PROVU NTEP Certified pulse input batch controllers
Brand:
PRECISION DIGITAL
| Category:
Controller
| Size: 4 MB
Table of Contents
Table of Contents
3
Table of Figures
4
Introduction
5
Ordering Information
6
Specifications
7
General
7
Pulse Input
7
Batch Controller Rate/Totalizer Display
8
Relays
8
Isolated 4-20 Ma Transmitter Output
9
Modbus ® RTU Serial Communications
9
PDA1044 Digital Input & Output Expansion Module
9
Meterview Pro
9
Compliance Information
10
Safety
10
NTEP Weights and Measures Certification
10
Electromagnetic Compatibility
10
Safety Information
11
Installation
11
Unpacking
11
Figure 1: 1/8 DIN Panel Mounting
12
Figure 2: Controller Dimensions - Side View
12
Figure 3: Controller Dimensions - Top View
12
Panel Mounting Instructions
12
Mounting Dimensions
12
Figure 4: Transmitter Supply Voltage Selection
13
Transmitter Supply Voltage Selection (P+, P-)
13
Figure 5: Programming Lockout Jumper Selection
14
Programming Lockout Jumper (NTEP Lockout)
14
Figure 6: Wire Security Seal and Bracket
15
Figure 7: Wire Loop through Rear Case Pass-Through
15
Figure 8: Wire Loop through Security Bracket Pass-Through
15
Figure 9: Close and Crimp Seal Wire Security Loop
15
Wire Security Seal Installation (NTEP Seal)
15
Figure 11: Power Connections
16
Figure 10: Connector Labeling for Fully Loaded
16
Modbus RTU Serial Communications
17
Pulse Input Signal Connections
17
Relay Connections
17
Connections
16
Connectors Labeling
16
Power Connections
16
Figure 15: NPN Open Collector Input
17
Figure 16: PNP Sensor Powered by Internal Supply
17
Figure 17: Switch Input Connections
17
Figure 18: Relay Connections
17
Figure 19: AC and DC Loads Protection
18
Figure 20: Low Voltage DC Loads Protection
18
Figure 21: F4 Digital Input Connections
18
4-20 Ma Output Connections
19
Analog Output Transmitter Power Supply
19
External Relay & Digital I/O Connections
19
Figure 22: 4-20 Ma Output Connections
19
Figure 23: Expansion Modules & DIN Rail Mounting Kit
19
Figure 24: External Relays Module Connections
19
Figure 25: Digital I/O Module Connections
19
Interlock Relay Feature
20
Figure 14: Self-Powered Magnetic Pickup Coil Flowmeter
17
Figure 13: Flowmeter Powered by External Supply
17
Figure 12: Flowmeter Powered by Internal Power Supply
17
F4 Digital Input Connections
18
Switching Inductive Loads
18
Figure 26: Interlock Connection
20
Basic Operation and Programming
21
Front Panel Buttons and Status LED Indicators
21
Controller Operation
22
Batch Control Operation Example
23
Meterview ® Pro Software
25
Meterview Pro Installation
25
Display Functions and Messages
26
Setting Numeric Values
28
Setting up the Batch Controller (Setup)
29
Scaling and Calibration
30
Setting the Input Signal (Input)
30
Setting the Totalizer and Batching Features (Total)
30
Setting the Input Units or Custom Tags (Units)
30
Setting the Decimal Point (Dec Pt)
31
Programming the Batch Controller (Prog)
31
Input Calibration Method (Incal)
32
K-Factor Calibration (Factor)
32
Scaling the Controller (SCALE)
33
Time Base, Total Conversion Factor & Total Reset
33
Batch Start Mode (Mode)
34
Calibrating the Controller with External Source (Cal)
34
Setting the Display Parameter & Intensity (Dsplay)
35
Setting the Relay Operation (Relay)
36
Relay Assignment (Assign)
37
Setting the Relay Action
37
Setting Batch Control Relays
37
Programming Alarm Set and Reset Points
38
Setting Fail-Safe Operation
38
Programming Time Delay
38
Relay Operation Details
39
Overview
39
Relays Initialization
39
Fail-Safe Operation
39
Front Panel Leds
39
Automatic Reset (Auto)
40
Pump Alternation Control
40
Setting up the Interlock Relay (Force On) Feature
40
Sample Relay Operation
41
Relay and Alarm Operation Diagrams
41
High Alarm Operation (Set > Reset)
41
Low Alarm Operation (Set < Reset)
41
High Alarm with Fail-Safe Operation (Set > Reset)
41
Low Alarm with Fail-Safe Operation (Set < Reset)
41
Rate Relay Sampling Operation
42
Total Relay Sampling Operation
42
Time Delay Operation
43
Scaling the 4-20 Ma Analog Output (Aout)
43
Reset Menu (Reset)
44
Control Menu (Contrl)
44
Setting up the Password (Pass)
44
Protecting or Locking the Controller
44
Grand Total Reset Password & Non-Resettable Total
45
Making Changes to a Password Protected Controller
45
Disabling Password Protection
45
Advanced Operation and Programming
46
Advanced Features Menu & Display Messages
46
Function Keys Operation
48
F4 Operation
48
Multi-Point Calibration & Scaling
48
Maximum/Minimum Readings
48
Noise Filter (Filter)
49
Rounding Feature (Round)
49
Modbus RTU Serial Communications (Serial)
49
Select Menu (Select)
50
Signal Conditioning Selection (Functn)
50
Low-Flow Cutoff (Cutoff)
50
Total and Grand Total Count Direction (Count)
50
Analog Output Programming (Aoutpr)
51
Programmable Function Keys User Menu (User)
51
Troubleshooting
53
Diagnostics Menu (Diag)
53
Determining Software Version
53
Reset Controller to Factory Defaults
53
Factory Defaults & User Settings
54
Troubleshooting Tips
56
EU Declaration of Conformity
57
Advertisement
Advertisement
Related Products
PRECISION DIGITAL PD6310-6R4
PRECISION DIGITAL PD6310-6R5
PRECISION DIGITAL PD6310-7R5
PRECISION DIGITAL PD6310-7R7
PRECISION DIGITAL PD6310-7H2
PRECISION DIGITAL PD6310-6H4
PRECISION DIGITAL PD6310-6H5
PRECISION DIGITAL PD6310-6H7
PRECISION DIGITAL PD6310-6R2
PRECISION DIGITAL PD6310-6H2
PRECISION DIGITAL Categories
Measuring Instruments
Controller
Monitor
Scanner
Test Equipment
More PRECISION DIGITAL Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL