Sign In
Upload
Manuals
Brands
PowerFleet Manuals
GPS
Cellocator CelloTrack 4
PowerFleet Cellocator CelloTrack 4 Manuals
Manuals and User Guides for PowerFleet Cellocator CelloTrack 4. We have
1
PowerFleet Cellocator CelloTrack 4 manual available for free PDF download: Programming Manual
PowerFleet Cellocator CelloTrack 4 Programming Manual (286 pages)
Brand:
PowerFleet
| Category:
GPS
| Size: 5 MB
Table of Contents
Cellocator Cello Programming Manual - Cellotrack 4
1
Legal Notices
2
Intellectual Property
3
Table of Contents
4
Introduction
14
About this Document
14
Applicability Table
14
Document Conventions
15
Accessing the Configuration Memory Via Wireless Channel (OTA)
16
Accessing the Configuration Memory Via Direct Wire Interface
17
Event Types Generated by Cellocator Devices
17
Logged (Plain) Event
17
Distress Event
17
Security Event
18
Active Logged (Plain) Event
18
Address and Bitmask Field Allocation Tables
19
Address Allocation Table
19
Bitmask Field Allocations
31
Application Configuration
31
Communication Events Mask
33
Communication Settings in Home/Roam GSM Network Mode
34
WAKE up Message Configuration
34
GPS Management Bitmap
34
Maintenance Server Configuration Bitmap
35
UART Configuration
35
Alternative Inputs Usage Bitmap
35
Time Based Mask Bitmap
35
Over (and Idle) Speed Session Control Bitmap
36
Go/Halt Session Control Bitmap
36
GPS Alerts Mask Bitmap
36
Time Report Period Value (Home, Roam, High Speed)
37
Time/Distance Alert Multipliers for High Speed Mode
37
Date and Time Features
37
Discrete Inputs Masks
37
Mask of Analog Inputs Alerts
38
Geo-Fence Alert Mask
38
Offline Tracking - Auto Upload Configuration
38
Active Correlation Lines
39
Vector Change Detection Bitmask
39
Accelerometer Configuration
39
Towed Mode Configuration
39
GPS Power Mode
40
Tractor / Trailer Matching
40
Zeppelin Configuration 1
40
Zeppelin Configuration 2
41
OTA Type 11 Additional Configuration
41
LV300 Power Preservation Configuration
41
Health Monitor Enable and Report Entity Bitmask
41
Health Monitor Bitmask
42
Communication and Configuration
43
Communication Events
43
SIM Selection
43
Communication Settings
43
GPRS Settings
43
SMS Settings
56
Comm. Permissions in Home/Roam Network
57
COM Port Settings
58
Distress Session Configuration
58
Wake up Messages
60
Number of Repetitions
60
Offline Tracking
61
Cell ID Based Location (Neighborhood List of the Serving GSM Cell)
65
Internal Accelerometer Configuration
69
Roaming List, GSM Operator Management
70
GSM Jamming Detection & Reaction
74
Output Name
77
Output Number
77
Other Parameters Related to Communication Settings
82
Default Value
83
Add RC# Info
83
GPS Configuration
84
Base Unit (Measurement Factor of GPS Odometer)
84
GPS Odometer Current Value
84
Report Max. Speed Instead of Real Time Speed
85
Enable GPS Navigation Start-Stop Updates
85
GPS Navigation Start/Stop Filter
85
Enable Tight GPS PMODE Filter
85
GPS DOP Threshold
86
GPS Accepted Accuracy Threshold
86
Synchronize Unit's Time with GPS Time Only When GPS Is Navigating
87
Velocity Threshold for HIGH SPEED Mode
87
GPS Maintenance Updates
87
GPS Odometer Management
88
GPS Reset Settings
89
Enable WAAS (for USA and Hawaii)
90
Inputs & Outputs
90
Discrete Inputs Triggering Time Filters
90
Analog Measurement Averaging Time
91
Enable Monitoring Logical Status of Ignition in OTA Packets
91
Analog (& Frequency) Inputs in OTA Message
92
Usage Counter Configuration
92
Modem & SIM
94
Power Management
100
Power Management Mode
100
Current Consumption
100
Hibernation Mode Delay
101
Enable Pre-Hibernation Update
101
Enable Data Forwarding from Serial Port by SMS (in Hibernation)
101
GPS Peeking
102
GSM Peeking
103
Informative Parameters
104
Last Distance Event
104
Field for Customer Use
104
Distance and Speed Events
105
Distance Events
105
Enable Distance Updates
105
Trip for a Distance Event
105
Distance Event Multiplier for HIGH SPEED Mode
105
Over and Idle Speed
106
Velocity Threshold for over Speed Start Event
106
Velocity Threshold for over Speed End Event
106
Filter of over Speed Duration
106
Do Not Use Time Filter to Close over Speed Session
107
Alternative over Speed Threshold for Input Dependent Mode
107
Velocity Threshold for Idle Speed Start Event
108
Velocity Threshold for Idle End Event
108
Filter of Idle Speed Duration
108
Multiplier for Idle Speed Start Detection Time Filter
108
Do Not Use Time Filter to Close Idle Speed Session
109
Start Idle Speed Timer with Ignition on
109
Create Idle/Over Speed End Update for an Open Session Per Ignition off
109
Events and Distress Control
109
Sudden Course Changed and Sudden Speed Change Sensors
110
Speed Thresholds V0, V1 and V2
110
Delta Speed and Delta Course for Speed Range X
111
Events, Distress Updates Control
112
Time and Trip Events
113
Start and Stop Alerts
113
Start Alert Generation Time Filter
113
Stop Alert Generation Time Filter
113
Time-Based Alert
113
Time Alerts Resolution Definer
114
Time Alerts Period Value
114
Force One Second Resolution Roaming Mode
114
Time Alert Period Multiplier for High Speed Mode
114
Time Report Period Multiplier for NOIP Mode
115
Table of Time-Based Alert Period Calculation
115
Home Network
115
V-Trek: Dynamic Time-Based Alerts Period Control as a Function of Speed
116
Curve Smoothing
118
Enable Vector Change Detection Events /Distress
119
Enable Compressed Vector Change Report
120
Compressed Vector Change Report Timeout
120
Vector Change Detection Angle
121
Communication Idle Alerts
121
Time between Communication Idle Alerts
121
Event and Distress Controls for Communication Idle Alert
121
Do Not Wake up from Hibernation Upon Comm. Idle Distress
121
Inputs Events
124
Door
124
Door Input Type
124
Function Assigned to Door Input
124
Function Description
125
Scaling Factor for Frequency Report on Door Input
125
Thresholds on Door as a General Purpose Frequency Counter
127
Time Filter for Frequency/Analog Door Input
127
Door Freq. Input Violation Type
127
Threshold for Door Input
128
Averaging Factor for Door Input
129
Inverting Door Input
129
Reporting Signal Falling on Door
129
Reporting Signal Rising on Door
130
Function Buttons Events - Door Input
130
15 - Shock
130
Shock Input Type
130
Function Assigned to Shock Input
131
Scaling Factor for Frequency Report on Shock Input
132
Threshold on Shock as a General Purpose Frequency Counter
134
Time Filter for Violation of Frequency / Analog Shock Input
134
Shock Freq. Input Violation Type
134
Threshold for Shock Input
135
Averaging Factor for Shock Input
136
Inverting Shock Input
136
Reporting Signal Falling on Shock Input
136
Reporting Signal Rising on Shock Input
137
Function Buttons Events - Shock Input
137
16 - Panic
137
Function Assigned to Panic Input
137
Inverting Panic Input
138
Threshold for Panic Input
138
Averaging Factor for Panic Input
139
Reporting Signal Falling on Panic
139
Reporting Signal Rising on Panic
139
Power Events
140
Power Threshold Settings
140
Main Power Low Threshold - High/Low Levels
140
Geo-Fences
141
Geo-Fence
141
Format of Geographical Perimeter
142
Four Configuration Bytes of the Fence
142
TOE - Type of Entry
143
Waypoint
143
Geo Hot Spot
143
No Modem Zone
144
Fences Configuration
144
Geo-Fence Logic
144
Geo-Fence Violation Filter
145
Ignore Geo-Fence Violation on Boot (after Reset)
145
Control of Geo-Fence Alters (Events and Distress)
146
Geo-Fence Priority
147
Towing Detection and Towed Mode (Supported on Cello and CR Families and CT-LTE-Power)
149
Towed Mode
149
Enable Towed Mode
150
Enable Towed Mode Start-Stop Distress/Event
150
Cellotrack
151
Cellotrack Configuration 1
151
Cellotrack Configuration 2
153
Disable Cell ID Packets on Peeking
153
Enable Fixtime Algorithm (Non Cellotrack T Variants Only)
153
Enable Extended Charging Temperature Range
154
GPIO Control 1/2 (Cellotrack Only)
154
Cradle Mount Power Save (Cellotrack Only)
155
GPS Peeking on Time During Live Tracking
155
Activation/Deactivation Procedure Options
156
Activation/Deactivation Procedure
156
GPS-Based Start Event Enable (Non Cellotrack T Variants Only)
157
GPS-Based Movement Timeout (Non Cellotrack T Variants Only)
158
Max Extra GPS on Time for Distress Mode
158
Distress Mode During COM-Location Glancing State
158
Glancing at Specific Time (ST Glancing)
159
Radio-Off (Cellotrack and Cellotrack Power)
161
Advanced Glancing (Peeking): Cellotrack and Cellotrack Power
162
Cradle Tamper Events Definitions
164
Cellotrack Power
165
Cellotrack Power and Nano Configuration Settings
165
Slow Charging in Extreme Temperatures
166
Cellotrack-Phoenix (LV300P Only)
167
Phoenix Sensor Feature Enable
167
Important Note
168
Phoenix Sensor-Sampling During Stop Only-Rule
168
Phoenix Sensor Presence-Status-Change Type-11 Event
169
Phoenix Sensor Sample Interval When External Power Connected
169
Phoenix Sensor Sample Interval When External Power Disconnected
169
Time Limit of Periodic Sampling When External Power Disconnected
169
Asynchronous Sample - When External Power Is Disconnected
170
Asynchronous Sample - When External Power Is Disconnected & BOD Event
170
Asynchronous Sample - When External Power Is Disconnected & EOD Event
170
LV300P & Smart Trailer (Hyundai)
170
Enable Hyundai HT Logic
171
LV300- Power Preservation Mode
173
LV300 Preservation Mode Activation and Configuration
178
Time between Periodical Listen Event Transmission in LV300 Preservation
179
Periodic Events Transmission Rate During BOD State While in LV300 Preservation Mode
179
Cellotrack Nano
180
Overview
180
System Modes
181
Improved Tracking Mode
181
Sampling Rate
182
Improved Tracking with POD Mode (Infrastructure)
182
The Layers Concept
182
Usb
183
Usage
183
Charging Speed
183
Charging Modes
183
Power-Bank Keep Alive Pulsing
184
Sensors
186
Use of IIR Filters
187
Accelerometer
188
BLE Functionality
188
Communication Protocols
188
Parameters Descriptions and Notes
188
Nano Take Location Interval
188
GPS Warm Start
189
Legacy Events Type-11 Configuration
189
Tilt Tamper
190
Accelerometer Based Impact / Free-Fall Detection
192
Orientation Change
193
Package Open/Close Events
194
Analog Source Selection
196
Sensor Type
197
Temperature and Humidity Measurements
197
Buzzer Configuration
204
Leds Configuration
205
Check-In_Out Configuration
206
Work-ID (Activation) Messaging
207
Exception Handling
207
BLE Block
208
Dry Contact Input Mode
212
Add Module 44
212
Prevent Power Button from Shutting down (Nano)
213
Improved Power Consumption for High Transmission Rates
213
Cellotrack 10Y/Solar/Lte
215
Sensors
217
Temperature, Humidity, and Light Sensors
217
Accelerometer
218
External Interfaces
218
Leds
219
Blinking Pattern
219
Front Button
225
Tamper Switch
226
Large File Transfer (BLE Camera/Fcam)
226
Satellite Modem (CT-Solar V3)
228
Enable Satellite Modem
229
Monthly Quota Via Satellite Link
229
Satellite Pending Messages Check Period
229
Enable Send Via Satellite
229
Enable Via Satellite for Native Type-11 Events
230
Maximum Satellite Modem on Time
231
Power System (for Li/Soci2 Based)
231
Battery Measurement
231
Battery Status Manual Check
233
Battery Preservation Mode LV5XX Only
233
General Description
233
Timeout to Battery Preservation (LV5XX Only)
234
Battery Replacement Sequence
235
Tracking Mode
235
System Tracking Mode
235
BOD Distance Filter
238
BOD Check Period
238
EOD Time Filter
238
Time between Periodical Events During BOD on Super CAP
238
Additional Tsrs Every
239
Enable Boot up Report
239
Skip GPS Take Location for Idle Transmissions
239
BLE Wake up Period
240
BLE on Time
240
GPS Power Mode (CT-LTE Only)
240
Time between Periodical Listen Event Transmission
240
Time between Periodical Events During BOD on Battery (CT-Solar Only)
241
Movement after EOD Event
241
Idle Transmission Only in Working Hours
241
GSM Peeking Time - When Outside Geo-Fence
242
Geo-Fence Slot #1/2/3/4 - Alternative GSM Peeking Time
242
Etracking (Theft Mode) Transmission Interval When Moving & Outside Working Hours
242
Working Hours for Etracking (Theft Mode) Interval When Moving
242
GPS Stationary Anti-Drift Filter
243
Further Details
244
Flow Chart
245
Zeppelin - Mount/Unmount Detection
246
Enable Mount/Unmount Candidate by Impact Event
246
Enable Mount/Unmount by GPS SNR Event
247
SNR Delta Threshold for Zeppelin Mount/Unmount Detection
248
1.1.1 Maximum SNR for Zeppelin Mount Detection
248
1.1.2 Minimum SNR for Zeppelin Unmount Detection
248
Zeppelin Postpone Mount Event until Short Drive Verification
249
Enable Mount/Unmount by Drive Noise Event [Provision Only]
249
Zeppelin Mount by GPS SNR During Drive
250
Zeppelin Unmount by GPS SNR During Drive
250
Zeppelin Mount/Unmount Only Outside Geo-Fence
251
Zeppelin off Battery Voltage Threshold
251
Wireless BLE Sensors
253
Introduction to Multisense and Multisense-TH
253
Operation
254
Marking
254
Battery
254
Button and Blue LED
254
Pairing Process
254
Unpairing Process
255
Sensors
256
Accelerometer
256
Ambient Light Sensor (ALS)
256
Accurate Temperature Sensor
256
Humidity Sensor
256
Magnetic Sensor
256
Parameter Descriptions and Notes
257
Multisense Units Provisioning
257
Multisense Open/Close Door/Window Feature
257
BLE Pairing Time Window
258
Specific Multisense Parameters
258
Advanced BLE Settings
262
Data Logger Full Processing
262
Group-ID
263
Multisense Tx Duration
263
Multisense Connection Timeout
263
Multisense Timers Multiplier
264
No Multisense Received Timer
264
No Multisense Received Message Every
264
Force Configuration
264
BLE RSSI for Auto MS/CS Config
265
Cellosense
266
Introduction
266
Concept of Operation
267
Motion Detection Feature
267
Magnetic Sensor as Pushbutton
269
Zone-2 Moving Tx Rate
269
Zone-1 Phase-A Lifting Motion Activity Total Time
270
Zone-1 Phase-A Lifting Sliding Window Size
270
Accelerometer ODR
270
Acceleration Motion Pulse Width for Zone-1 Phase-A
271
Maximum Time in Yard
271
Zone-1 Phase-A Lifting Threshold
271
Zone-1 Phase-B Advertisement Tx Rate
271
Enable Lv/Nano to CS Connections after Lifting Detection (Zone 1)
271
2Nd Alternative Settings for Zone 2
272
2Nd Alternative Relax Timer
273
2Nd Alternative Violation Timer
274
2Nd Alternative Proximity/Keep-Alive Timer
274
2Nd Alternative Timers Multiplier
274
2Nd Alternative Motion Detection Start Filter (Global)
275
2Nd Alternative Motion Detection Stop Filter (Global)
275
Zone-2 Moving Tx Rate Timeout
275
Tractor/Trailer Matching
276
Enable Tractor/Trailer Match Unmatch
276
Allow Pairing to the Cellosence Even if Already Paired
277
Allow Pairing to the Lvx00 Even if Already Paired
277
Reduce TX Rate During Long Movement Timeout
278
Maximum RSSI for Pairng
278
Enable Tractor Trailer OTA Tracing
278
Cble
280
CBLE Scan Cycle
280
CBLE Scan Duration
280
CBLE Tx Power
280
Advertisement Duplications Filter
281
Health Monitor
282
Overview
282
Health Report for Entity
284
Health Report Period
284
Health Report -Diagnostic Start Time
285
Health Report -Server Setting
285
Health Report -BLE TX Reason 1
285
Health Report -BLE TX Reason 2
286
Advertisement
Advertisement
Related Products
PowerFleet Categories
Digital Camera
Automobile Accessories
Dash Cameras
Security Sensors
Data Loggers
More PowerFleet Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL