PowerFleet Cellocator CelloTrack 4 Programming Manual

Table of Contents

Advertisement

Quick Links

Cellocator Cello
Programming Manual -
CelloTrack 4
Proprietary and Confidential
Version 5.5.0.3
Revised and Updated: July 28, 2022
CELLOCATOR - A POWERFLEET® BRAND. 14 HAMELACHA ST. ROSH HA'AYIN 4809133, ISRAEL ● TEL: 972-3-5723111 ●
WWW.CELLOCATOR.COM
Copyright © 2021 by PowerFleet Inc.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Cellocator CelloTrack 4 and is the answer not in the manual?

Questions and answers

Summary of Contents for PowerFleet Cellocator CelloTrack 4

  • Page 1: Cellocator Cello Programming Manual - Cellotrack 4

    Cellocator Cello Programming Manual - CelloTrack 4 Proprietary and Confidential Version 5.5.0.3 Revised and Updated: July 28, 2022 CELLOCATOR - A POWERFLEET® BRAND. 14 HAMELACHA ST. ROSH HA'AYIN 4809133, ISRAEL ● TEL: 972-3-5723111 ● WWW.CELLOCATOR.COM Copyright © 2021 by PowerFleet Inc.
  • Page 2: Legal Notices

    (iii) caused by use of any software not supplied by PowerFleet Inc., or by use of the product other than in accordance with its documentation, or (iv) the result of electrostatic discharge, electrical surge, fire, flood or similar causes.
  • Page 3: Intellectual Property

    Manual Intellectual Property Copyright in and to this document is owned solely by PowerFleet Inc. Nothing in this document shall be construed as granting you any license to any intellectual property rights subsisting in or related to the subject matter of this document including, without limitation, patents, patent applications, trademarks, copyrights or other intellectual property rights, all of which remain the sole property of PowerFleet Inc.
  • Page 4: Table Of Contents

    5.2.17 Mask of Analog Inputs Alerts ..................38 5.2.18 Geo-Fence Alert Mask ....................38 5.2.19 Offline Tracking - Auto Upload Configuration ..............38 5.2.20 Active Correlation Lines ....................39 Cellocator Programming Manual Page 4 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 5 6.3.10 Velocity Threshold for HIGH SPEED Mode ..............87 6.3.11 GPS Maintenance Updates ................... 87 6.3.12 GPS Odometer Management ..................88 6.3.13 GPS Reset Settings ..................... 89 Cellocator Programming Manual Page 5 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 6 7.3.1 Speed Thresholds V0, V1 and V2 ................110 7.3.2 Delta Speed and Delta Course for Speed Range X ............111 7.3.3 Events, Distress Updates Control ................112 Cellocator Programming Manual Page 6 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 7 9.2.3 Scaling Factor for Frequency Report on Shock Input ............. 132 9.2.4 Threshold on Shock as a General Purpose Frequency Counter ........134 9.2.5 Time Filter for Violation of Frequency / Analog Shock Input ........... 134 Cellocator Programming Manual Page 7 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 8 12.1.2 Enable Towed Mode Start-Stop Distress/Event ............. 150 CelloTrack ......................151 13.1 CelloTrack Configuration 1 ..................151 13.2 CelloTrack Configuration 2 ..................153 13.2.1 Disable Cell ID Packets on Peeking ................153 Cellocator Programming Manual Page 8 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 9 CelloTrack Nano ....................180 15.1 Overview ......................... 180 15.2 System Modes ......................181 15.2.1 Improved Tracking Mode ................... 181 15.2.2 Improved Tracking with POD Mode (Infrastructure) ............182 Cellocator Programming Manual Page 9 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 10 16.2.1 LEDs ........................219 16.2.2 Front Button ......................225 16.2.3 Tamper Switch ......................226 16.2.4 Large file transfer (BLE camera/FCAM) ................ 226 16.3 Satellite modem (CT-Solar V3) ................... 228 Cellocator Programming Manual Page 10 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 11 16.6.4 Enable Mount/Unmount by Drive Noise Event [Provision only] ........249 16.6.5 Zeppelin Mount by GPS SNR During Drive..............250 16.6.6 Zeppelin Unmount by GPS SNR During Drive ............... 250 Cellocator Programming Manual Page 11 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 12 17.6.7 Accelerometer ODR ....................270 17.6.8 Acceleration motion pulse width for Zone-1 Phase-A ............. 271 17.6.9 Maximum time in yard ....................271 17.6.10 Zone-1 phase-A lifting threshold ................271 Cellocator Programming Manual Page 12 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 13 18.1.3 Health Report -Diagnostic start time ................285 18.1.4 Health Report –server setting ..................285 18.1.5 Health Report –BLE TX reason 1 ................. 285 18.1.6 Health Report –BLE TX reason 2 ................. 286 Cellocator Programming Manual Page 13 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 14: Introduction

    Driver Authentication, Audio call, CFE, Pulse Counter, APS mode in 2G variant, and GSM Jamming in 3G variant. Most of the functionality is also inherited to CelloTrack- Nano units. Cellocator Programming Manual Page 14 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 15: Document Conventions

    This document defines the common programmable features, supported by all the modifications of Cellocator units, as well as the specific programmable options, supported by specific modifications only. The non-common options are highlighted. Cellocator Programming Manual Page 15 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 16: Accessing The Configuration Memory Via Wireless Channel (Ota)

    0 (zero). The following blocks are assigned with successive numbers (block 1 for locations 16 to 31 and so on). Refer to the Cellocator Wireless Communication Protocol document for more information about accessing the CM via the wireless channel. Cellocator Programming Manual Page 16 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 17: Accessing The Configuration Memory Via Direct Wire Interface

    The session will be stopped by any other distress session or by a command from the OTA. Distress sessions may be prolonged by up to 20 seconds after the transmission of the last distress message. Cellocator Programming Manual Page 17 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 18: Security Event

    Prior to this feature, users had to configure both “Event” and “Distress” bits to achieve this functionality. Cellocator Programming Manual Page 18 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 19: Address And Bitmask Field Allocation Tables

    Base unit (measurement factor of GPS odometer) Max Time between GPS readings for SxT calculation 85 - 88 GPS odometer - Last Distance Event (in base units) Cellocator Programming Manual Page 19 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 20 128 - 129 Inputs Distress mode mask - on Falling 130 - 131 Inputs Distress mode mask - on Rising 132 - 133 Towing detection – Speed threshold Cellocator Programming Manual Page 20 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 21 Advanced GSM Jamming Detection – Ignition Off - Delay for output activation for the 1 output (Infrastructure) Advanced GSM Jamming Detection – Ignition Off - Delay for output activation for the 2 output (Infrastructure) Cellocator Programming Manual Page 21 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 22 Offline Tracking - Time to Auto Upload after Trip Stop GPS Peeking – Max. On Time 264 - 265 GPS Peeking – Off Time Power Management mode Cellocator Programming Manual Page 22 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 23 Max Extra GPS On Time for Distress Mode Velocity threshold for HIGH SPEED mode Additional inputs functionality control bitmask Analog Measurement Averaging Time Accelerometer Configuration Voltage Level Threshold IgnitionOn Detection Internal variable: AHR counter Cellocator Programming Manual Page 23 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 24 Time event period in Roaming GPS Navigation Start/Stop Filter Maximum number of AHR retries GPS management bitmap Acceleration Threshold for Speed range 0 Acceleration Threshold for Speed range 1 Cellocator Programming Manual Page 24 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 25 1005 Geo-Fence Alert Mask for distress 1006 Geo-Fence violation filter 1008 Roaming Operator’s Management - Timer of Auto-Search 1009 Roaming Operator’s Management - Number of PLMNs programmed Cellocator Programming Manual Page 25 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 26 Advanced Glancing (peeking): Glancing time for movement and charging state. 1344 Wake Up message configuration 1347 Application Configuration byte 5 1348 Application Configuration byte 6 1349 Application Configuration byte 7 Cellocator Programming Manual Page 26 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 27 Time event resolution multiplier for “external power” mode 1620 Select Measurement source reported in Byte 26 of OTA Msg type 0 1621 Select Measurement source reported in Byte 27 of OTA Msg type 0 Cellocator Programming Manual Page 27 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 28 CFE Bluetooth Page Mode 1755-1756 CFE Reserved 1757 CFE Page scan mode 1758-1766 CFE Bluetooth Pin Code 1767-1768 CFE Infrastructure for COM 2 (Bluetooth) configuration 1769-1777 CFE Bluetooth Configuration (Infrastructure) Cellocator Programming Manual Page 28 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 29 CFE Spare 1834 CFE Input5 Type / Assigned function 1835 CFE Averaging factor for Input5 1836-1837 CFE Scaling Factor for Frequency report 5 1838 CFE Discrete Wet/Dry Threshold Cellocator Programming Manual Page 29 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 30 Operational Server DNS Address 2496-2516 Geo-Fence 1 Configuration …. …. 4080-4095 Geo-Fence 100 Configuration 6643 Especial Speed Threshold 1 6644 Especial Speed Threshold 1 Timeout 6645 Especial Speed Threshold 2 Cellocator Programming Manual Page 30 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 31: Bitmask Field Allocations

    Reserved Reserved Renew GPRS _Enable_Unit_Ignition- upon drop in (in semi- hibernation) Bits 7 Bits 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Cellocator Programming Manual Page 31 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 32 Bit 1 Bit 0 Address: 1348, Application Configuration byte 6 Enable Offline Consider Disable Enable tracking Unknown Auto SIM Operators Jamming Event locking Forbidden (Legacy + Ignition Cellocator Programming Manual Page 32 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 33: Communication Events Mask

    Stream Event watchdog modem message (CelloTrack- feedback 10Y only) Bit 7 Bit 6 Bit 5 Bit 4 Bits 2-3 Bit 0-1 5.2.2 Communication Events Mask Address: 604 Cellocator Programming Manual Page 33 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 34: Communication Settings In Home/Roam Gsm Network Mode

    Reset last Enable Enable Speed Not used Enable WAAS Tight GPS known Pythagoras x Time (for USA and PMODE location on Calculation Calculation Hawaii) Filter Ignition off (SxT) Cellocator Programming Manual Page 34 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 35: Maintenance Server Configuration Bitmap

    Communication Idle Do not wake up from hibernation upon comm.idle distress Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Cellocator Programming Manual Page 35 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 36: Over (And Idle) Speed Session Control Bitmap

    Not used Enable Go/Halt Events 0 – Disable 1 - Enable Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Cellocator Programming Manual Page 36 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 37: Time Report Period Value (Home, Roam, High Speed)

    Address: For Inversion 100-101 Inputs Events on Falling 124-125 Inputs Events on Rising 126-127 Inputs Distress on Falling 128-129 Inputs Distress on Rising 130-131 Lower byte Driving Panic Status Cellocator Programming Manual Page 37 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 38: Mask Of Analog Inputs Alerts

    Offline Tracking - Auto Upload Configuration Address: 255 Unused Memory Ignition Off Full Event Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Cellocator Programming Manual Page 38 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 39: Active Correlation Lines

    Bit 6 Bit 5 Bits 3-4 Bit 2 Bit 1 Bit 0 5.2.23 Towed Mode Configuration Address: 470 Bits 6-7 Bit 5 Bits 2-4 Bit 1 Bit 0 Cellocator Programming Manual Page 39 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 40: Gps Power Mode

    Unmount by Mount event SNR During until verified Drive after short drive Bit 7 Bit 6 Bit 5 Bit4 Bit 3 Bit 2 Bit 1 Bit 0 Cellocator Programming Manual Page 40 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 41: Zeppelin Configuration 2

    0=off 0=off 0=off reserved 1=on 1=on 1=on 1=on 1=on 1=on 1=on Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Cellocator Programming Manual Page 41 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 42: Health Monitor Bitmask

    1=on 1=on 1=time acquisition and 00:00 UTC time reached Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Cellocator Programming Manual Page 42 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 43: Communication And Configuration

    NOTE: Legacy units used to have 16 concurrent pending events. Cellocator Programming Manual Page 43 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 44 The Anti-flooding will randomize the idle communication time between message retransmission sessions to avoid server overloading in situations where the server becomes available after period of server unavailability and to avoid network overloading. Cellocator Programming Manual Page 44 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 45 1.1.1.1.4 Anti-Flooding Timer Address: 284 Description: This parameter defines a "communication idling" timeout, used by the unit to decrease a communication costs during the server (CCC) failure. Cellocator Programming Manual Page 45 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 46 Intermediate state of Anti-Flooding Activation Control Address: 202, bit 1 for home network 204, bit 1 for roam network 4, bit 1 for hibernation, if enabled for active GSM network Cellocator Programming Manual Page 46 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 47 Data format: 24 bytes string, first byte is length Value span: First byte 0 to 0x17, second to 24th - ASCII characters Default value: ASCII "test" Cellocator Programming Manual Page 47 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 48 Labels are restricted to a small subset of the ASCII character set known as LDH, the Letters A–Z in upper and lower case, Digits 0–9, Hyphen, and the dot to separate LDH-labels; see RFC 3696 section 2 for details. Cellocator Programming Manual Page 48 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 49 Valid values: According to the table below: Value Network UDP/IP over GPRS Not supported TCP/IP over GPRS Default value: 4 - TCP/IP over GPRS Cellocator Programming Manual Page 49 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 50 If all the retries fail, the unit will stop trying and connect back to an operational server (instead of entering Anti-Flooding, as it would do while connected to an operational server). Cellocator Programming Manual Page 50 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 51 1398, Bit 6 Description: If this bit is enabled the unit will perform firmware upgrade even if the supercap is not full. Default value: 0 - Disable Cellocator Programming Manual Page 51 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 52 Data format: 1 byte with a resolution of 90 minutes (1.5 hours). In case of zero, the real period will be only {last 2 digits of decimal representing of unit's ID} [min] Value span: 0-15.9 days Cellocator Programming Manual Page 52 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 53 Data format: 4 bytes IP address, Intel order (low significant bytes first) Default value: 62.90.141.201 (current main maintenance server) 1.1.1.1.29 Default Target DNS Address (Maintenance Server) Cellocator Programming Manual Page 53 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 54 Description: This parameter defines the connection type of the maintenance server. Valid values: According to the table below: Value Network UDP/IP over GPRS Not supported TCP/IP over GPRS Default value: 0 1.1.1.1.33 Maintenance Server Session Time Update Cellocator Programming Manual Page 54 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 55 FW will cancel the 3 Min time out, or what is left of it, and replace it with a new session timeout value defined by this parameter. Valid values: Min time 30 Sec: 3 Resolution: 10 Sec Default value: 90 Seconds Cellocator Programming Manual Page 55 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 56: Sms Settings

    Example: If the parameter contains 07h 91h 79h 52h 14h 32h 54h F6h FFh, the address that will be used is the international address +972-54-123456, from left to right. Default value: NULL (blank). Cellocator Programming Manual Page 56 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 57: Comm. Permissions In Home/Roam Network

    Description: If this parameter is disabled, the unit will not generate any active SMS traffic (distress or real-time, except the "Wake Up" SMS messages, see description below), even if SMS communication is enabled in previous parameter. Default value: Disable (1) Cellocator Programming Manual Page 57 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 58: Com Port Settings

    Distress Session Configuration A Distress Session is one of four possible ways to deliver data to a Central Control (refer to the Event Types generated by Cellocator devices section). Cellocator Programming Manual Page 58 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 59 NOTE: A Distress session initiated by OTA command will contain the number of messages specified in a command. Legal values span: 01h (one transmission) through 00FFh (255 transmissions). 0 is illegal. Default value: 1 Cellocator Programming Manual Page 59 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 60: Wake Up Messages

    Description: This parameter defines the amount of SMS/GPRS Wake Up messages. In case of failure during sending Wake Up event via GPRS (ACK is not received), the unit will Cellocator Programming Manual Page 60 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 61: Offline Tracking

    If this bit is enabled (1) the unit switches the modem on and initiate the GPRS session only when data download is required (see below). The rest of the time the modem remains off. Cellocator Programming Manual Page 61 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 62 In such a case the modem will be switched off after the end of the maintenance session. There is no dedicated modem wake up for maintenance session. Cellocator Programming Manual Page 62 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 63 Description: If this bit is enabled (1), the unit will wake up the modem and establish GPRS session upon detection of memory overflow (90% full). Data Range: 1 - Enable, 0 - Disable Default Value: 0 - Disable Cellocator Programming Manual Page 63 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 64 Time Between Logged Events Upload Retries Address: 222 Description: This parameter defines the time between logged events upload retries (in case of no GSM connection when attempting to upload logged events). Cellocator Programming Manual Page 64 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 65: Cell Id Based Location (Neighborhood List Of The Serving Gsm Cell)

    (Cells) with known location, along with signal power or SNR (Signal to Noise Ratio) indication, might be used for location approximation of the transmitting device. Cellocator Programming Manual Page 65 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 66 The message, containing this information and CellID retrieval timestamp, will accompany any log or distress message (as per configuration) generated by Cellocator unit during GPS coverage loss. Cellocator Programming Manual Page 66 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 67 In 3G networks, information of the neighbor cells is not available. Thus, the modem is polled for current serving cell extended data, which may include sector data, which in turn may improve determining the unit location. Cellocator Programming Manual Page 67 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 68 This parameter enable enforcing to send the ACK always (regardless of the origin of the command) to the same SMS destination number. Default value: 0 – Disabled Cellocator Programming Manual Page 68 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 69: Internal Accelerometer Configuration

    Values span: 0 - Very insensitive, 1 – Normal, 2 - Very sensitive, 3 - Spare Default value: 1 – Normal Note: The Accelerometer Sensitivity feature is applicable also in CelloTrack T units from FW version 61c. Cellocator Programming Manual Page 69 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 70: Roaming List, Gsm Operator Management

    Data format: The parameter is an 8-bit integer, resolution of 10 minutes. Value span: 1 to 255 (10 minutes to 2550 minutes, zero is automatically translated into 30 minutes) Default value: 6 Cellocator Programming Manual Page 70 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 71 The highest number in Priority field (15) is representing the most preferred network. The value of 1 is the lowest priority, 2 - higher priority and so on. Cellocator Programming Manual Page 71 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 72 In case no available network found during search, or all the available networks are “forbidden” – the unit will hold and proceed with searching after expiration of Timer of Auto Search. Default value: zeroes Cellocator Programming Manual Page 72 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 73 Mark the same operator as Let the modem select the suspended (until "Proceed to operator normal operation") Restart timer of available operator re-search Proceed with normal operation Cellocator Programming Manual Page 73 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 74: Gsm Jamming Detection & Reaction

    The Jamming events will also reflect the vehicle’s ignition state. The Ignition on jamming output activation configuration is the same configuration array used by the legacy jamming outputs activation. Cellocator Programming Manual Page 74 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 75 GSM jamming state change upon jamming start and end. The unit is immediately entering or leaving "Jamming" mode upon reception of the appropriate notification from the modem. Cellocator Programming Manual Page 75 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 76 The filter is common for both Ignition-on and Ignition-off jamming states. The timer resolution is 15 seconds. Default value: 10 Minutes Resolution: 15 second Cellocator Programming Manual Page 76 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 77: Output Name

    Description: This pair of parameters defines a numbers of outputs that will be activated upon jamming detection. Output name Output number Feature Disabled Siren Gradual Stop St. Immobilizer Cellocator Programming Manual Page 77 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 78 Activate Nested (executed upon jamming detection only after vehicle stops, e.g. Ignition off or 10 valid GPS packets showing speed lower than 1 km/h) Template Activation (according to the settings described below) Cellocator Programming Manual Page 78 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 79 During Ignition-Off) Description: This pair of parameters defines a number of activations of the selected output upon GSM Jamming detection. 0 – cancels outputs activation upon jamming detection Cellocator Programming Manual Page 79 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 80 The “Jamming-End” state is declared after no jamming detection is detected for the time defined in “GSM Jamming End Filter”: 0 - Jamming-End doesn’t affect the activation outputs. 1 - Jamming-End will deactivate the GSM Jamming activation outputs. Cellocator Programming Manual Page 80 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 81 (Requires that also parameter of "Enable Pre-defined driver ID's list" at address 123 bit-2, will be enabled). 0 - Disable 1 - Enable Default value: 0 - Disable Cellocator Programming Manual Page 81 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 82: Other Parameters Related To Communication Settings

    If the code will not be verified as authentic – the unit will not perform / acknowledge the command and will erase it. The unit supports dedicated Auth Table read/write commands over its wire protocol. See description of the commands in a corresponding documentation. Cellocator Programming Manual Page 82 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 83: Default Value

    11 packets, with information about the RC number of Main Firmware and its production- 0 = Disable (Don't add) 1 = Enable (Add module-113) Default value: 0 = Disable Cellocator Programming Manual Page 83 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 84: Gps Configuration

    FW upgrade, odometer skip back to the last 'Stop Report' value can be observed). Data format: The parameter is a 32-bit integer Value span: 00000000h to FFFFFFFFh Default value: 00000000h Cellocator Programming Manual Page 84 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 85: Report Max. Speed Instead Of Real Time Speed

    PMODE1=3 (in GPS Data, refer to the Cellocator Wireless protocol) or 4 and PMODE2=2. Otherwise any of the following values of PMODE1:2,3,4,5 or 6 will be accepted as a valid fix. Cellocator Programming Manual Page 85 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 86: Gps Dop Threshold

    TH will not considered to be valid fixes. Data format: unsigned 8 bits integer Valid Range: 2-510 meters. 0=Disable (pass everything) Resolution: 2 meters. Default value: 100 meters Cellocator Programming Manual Page 86 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 87: Synchronize Unit's Time With Gps Time Only When Gps Is Navigating

    (Refer to wireless protocol for GPS signal validity definition) The validity status changes after 10 consecutive GPS frames with the same validity status, different from the current one. Default value: Both Disable (0) Cellocator Programming Manual Page 87 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 88: Gps Odometer Management

    Note that in this case the vehicle will also ignore the distance, passed from Ignition On to first GPS fix obtained. Default value: 0 - Disable Cellocator Programming Manual Page 88 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 89: Gps Reset Settings

    Auto Hardware Reset (AHR) its GPS up to programmable number of retries (according to Maximum Number of AHR parameter used also for Modem AHR, 5 by default). Cellocator Programming Manual Page 89 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 90: Enable Waas (For Usa And Hawaii)

    Low to High event Common Common Additional Additional Discrete Inputs Discrete Inputs Begin End Time Time Filter Time Filter Time Filter Filter Cellocator Programming Manual Page 90 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 91: Analog Measurement Averaging Time

    Description: If this bit is enabled (1) the ignition bit in all any outbound messages (OTA and serial) will reflect logical status of Ignition (i.e. after the Ignition Filter) Default value: 0 - Disable Logical Cellocator Programming Manual Page 91 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 92: Analog (& Frequency) Inputs In Ota Message

    The time counting stops each time the logical level of the input changes from high to low. Dedicated Read/Write commands over RS232 and OTA are provided for Usage Counters, including a periodical Usage Counters update OTA packet. Cellocator Programming Manual Page 92 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 93 In order to set use only one Usage Counter input – select inexistent input number in this parameter (for example 4). Default value: 0 Cellocator Programming Manual Page 93 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 94: Modem & Sim

    Modem (i.e. the Pre-AHR mechanism didn't work), AHR will be performed. The process will repeat up to a programmable number of retries (configurable by "Maximum Number of AHR" parameter, address 504, bits 0-3). Cellocator Programming Manual Page 94 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 95 Description: If this bit is enabled the unit will store a plain event with dedicated transmission reason (address 200) upon each performed AHR. Default value: 0 - Disable Cellocator Programming Manual Page 95 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 96 P - Periodical Modem Reset parameter Tr - Periodical Modem Reset Threshold Wrong programming protection: If P≥Tr the unit will NOT use the low limit of randomization. Example: Cellocator Programming Manual Page 96 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 97 2G Only 3G Only 4G Only 2G+3G Support 2G+4G Support 3G+4G support Default value: 0 – Automatic Raws 5, 6 and 7 only for Telit’s LE910 C1 Cellocator Programming Manual Page 97 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 98 This parameter stores the new PIN code that should be used for locking the SIM Card during the SIM Lock procedure. This code will replace the Active SIM PIN on address 197- 200 upon successful completion of the SIM Lock procedure: Cellocator Programming Manual Page 98 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 99 PIN), the higher nibble should have all of its bits set (the nibble should contain 15 dec). The rest of the bytes that are not used should contain FFh. Cellocator Programming Manual Page 99 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 100: Power Management

    The unit does not respond to RS232 queries as well Note: In this mode Security Modification will not be able to detect Signal Correlation Default value: 2 Cellocator Programming Manual Page 100 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 101: Hibernation Mode Delay

    COM port (over CSP or Transparent Data protocols) through SMS in hibernation. (in case GPRS is not available or disabled, the forwarded data will be accumulated in unit's buffer). Default value: Disabled (1) Cellocator Programming Manual Page 101 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 102: Gps Peeking

    Value span: 1 (16 seconds between two consecutive peeks) through 65535 (~12 days between two consecutive peeks) Default value: 675 (3 hours from the end of one peek to the start of the next one) Cellocator Programming Manual Page 102 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 103: Gsm Peeking

    Value span: 02h (32 seconds between two consecutive peeks) through FFFFh (~12 days between two consecutive peeks). Values below 32 seconds (<02h) are illegal and shouldn’t be used. Cellocator Programming Manual Page 103 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 104: Informative Parameters

    Field for Customer Use Address: 1314 – 1317 Description: This field is designed to store customer’s proprietary data (like specific EEPROM content identifier). Data format: Customer defined Default value: zeros Cellocator Programming Manual Page 104 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 105: Distance And Speed Events

    For example: if Trip for a Distance event is set to 100 meters, and Distance Event Multiplier for roaming is set to 4, the unit will set distance updates in roaming mode to every 400 meters. Default value: Both 1 Cellocator Programming Manual Page 105 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 106: Over And Idle Speed

    (if enabled). Value resolution & span: Duration resolution is 2.5 Seconds. Duration Span from: 0 seconds (0x00h), to 10min 30 sec (0xFEh). Default value: 4 (10 seconds) Cellocator Programming Manual Page 106 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 107: Do Not Use Time Filter To Close Over Speed Session

    The same value is used for both Over-speed start and Over-speed end thresholds. The over-speed time filter (programmed on address 95) shall expire prior to alert generation irrespectively to the selected speed thresholds. Resolution: 32 cm/sec Default value: 70km/h Cellocator Programming Manual Page 107 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 108: Velocity Threshold For Idle Speed Start Event

    Description: This parameter contains a value of multiplier, used to increase dramatically Idle Speed Start detection time. Time for generation Idle Speed (Multiplier +1) Idle Speed Start Duration Filter Value of 0 disables multiplier. Cellocator Programming Manual Page 108 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 109: Do Not Use Time Filter To Close Idle Speed Session

    Description: If this bit is set the unit will generate distress session upon every Idle Speed start /end. Default value: 0 (disabled) 7.2.13.2 Enable Events for Idle Speed Start/End Address: 99, bit 3 Cellocator Programming Manual Page 109 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 110: Sudden Course Changed And Sudden Speed Change Sensors

    Speed Range 0 0 km/h The speed ranges threshold (V0, V1, V2) must meet the condition: V0<V1<V2 Data format: 8 bits parameters with resolution of 16 cm/sec Cellocator Programming Manual Page 110 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 111: Delta Speed And Delta Course For Speed Range X

    Default Values: Address (Dec) Value (Dec) Value 19.6 km/h 60 km/h 99.6 km/h 9.8 km/h 9.8 km/h 9.8 km/h 9.8 km/h 45° 45° 45° 45° 9.8 km/h Cellocator Programming Manual Page 111 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 112: Events, Distress Updates Control

    Description: If this bit is set, the unit will generate a corresponding update for any detected harsh course change. Note: sudden course change events which occurred when the speed is under 5 km/h will be filtered. Default Values: zeros (disabled) Cellocator Programming Manual Page 112 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 113: Time And Trip Events

    Speed: High Speed mode or Normal Speed mode. There is also a possibility of dynamic Time-based alert period modification as a function of speed, refer to V-Trek feature below. Cellocator Programming Manual Page 113 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 114: Time Alerts Resolution Definer

    Description: This parameter stores the Multiplier of time-based alert Period during High Speed mode. For example if the programmed value is 2, on speed higher then Velocity Cellocator Programming Manual Page 114 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 115: Time Report Period Multiplier For Noip Mode

    HSpeedHm – Time-based alert period multiplier for high speed mode in Home network, (bits 4:7 of address 92)  HSpeedRm – Time-based alert period multiplier for high speed mode in Roam network, (bits 4:7 of address 35) Cellocator Programming Manual Page 115 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 116: V-Trek: Dynamic Time-Based Alerts Period Control As A Function Of Speed

    On speed in range between V and V the transmission rate is dynamically changing: the update rate becomes slower as speed raises. Normal Slope is considered when the V >V Cellocator Programming Manual Page 116 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 117 V-Trek – V2 Speed Address: 1312 Description: This parameter contains the value of V2 speed in km/h; see V-Trek feature description above. Data format: unsigned integer, km/h Cellocator Programming Manual Page 117 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 118: Curve Smoothing

    "curve smoothing" with significant traffic increase), and the path on the map doesn't appear accurate enough, as shown below. Cellocator Programming Manual Page 118 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 119: Enable Vector Change Detection Events /Distress

    If compressed vector change report (next parameter) is disabled the unit will generate a dedicated event/distress type 0 with TR204 (Vector Change Report). Default value: Both disable Cellocator Programming Manual Page 119 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 120: Enable Compressed Vector Change Report

    No vector change detection occurrence is logged by the unit during the period defined in this parameter Range and resolution: Unsigned integer 8 bits, resolution of minutes Default value: 10 minutes Cellocator Programming Manual Page 120 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 121: Vector Change Detection Angle

    Idle alert in full hibernation, and therefore will not wake up from full hibernation upon expiration of Time between Communication Idle Alerts timeout. Default value: 0 - wake up from full hibernation to alert Comm. Idle Cellocator Programming Manual Page 121 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 122 Cellocator Programming Manual Cellocator Programming Manual Page 122 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 123 Cellocator Programming Manual Cellocator Programming Manual Page 123 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 124: Inputs Events

    Description: This field enables assignation of certain functionality to a Door input. Function Description Comment number Use as a GP input (default) Use as a GP frequency meter (refer to frequency metering section in this document) Cellocator Programming Manual Page 124 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 125: Function Description

    In case of Speed Source (Input's type 4, Assigned function 2): The value utilized as a speed [cm/sec] will be calculated as follows: �� = ���� ∗ ����[ ���� ������ ⁄ Cellocator Programming Manual Page 125 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 126 The value reported in OTA message type 0 will be therefore: ���� = ���� ∗ ����[����������/������] Es – reported value of engine speed [32RPM/Bit] Fs – Measured frequency Cellocator Programming Manual Page 126 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 127: Thresholds On Door As A General Purpose Frequency Counter

    If range type is selected - bit 0 defines if the violating value is inside or outside the range. Cellocator Programming Manual Page 127 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 128: Threshold For Door Input

    Value span for discrete type: 57 (0.2V) to 160 (1.45V). Any measured value below 57 or above 160 causes the unit to convert this value to default (125). Default Value: 125 (1V) Cellocator Programming Manual Page 128 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 129: Averaging Factor For Door Input

    1 to 0. In case this input is inverted, it will mean generation of the alert upon disconnection of this input from (-). Default Value: zeros – disabled (0 Cellocator Programming Manual Page 129 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 130: Reporting Signal Rising On Door

    Input Description Type number Discrete Dry Contact (on board pull-up) Discrete Normal (Wet Input) Cellocator Programming Manual Page 130 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 131: Function Assigned To Shock Input

    Reserved Volume Up (refer to Volume Control section in this document) Volume Down (refer to Volume Control section in this document) Reserved Over-speed threshold control Cellocator Programming Manual Page 131 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 132: Scaling Factor For Frequency Report On Shock Input

    The value utilized as a speed [cm/sec] will be calculated as follows: �� = ���� ∗ ����[ ���� ������ ⁄ S – Momentary value of speed [cm/sec] Fs – Measured frequency Cellocator Programming Manual Page 132 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 133 The value reported in OTA message type 0 will be therefore: ���� = ���� ∗ ����[����������/������] Es – reported value of engine speed [32RPM/Bit] Fs – Measured frequency Sf– scaling factor Cellocator Programming Manual Page 133 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 134: Threshold On Shock As A General Purpose Frequency Counter

    If range type is selected - bit 2 define if the violating value is inside or outside the range. Cellocator Programming Manual Page 134 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 135: Threshold For Shock Input

    Value span for discrete type: 57 (0.2V) to 160 (1.45V). Any measured value below 57 or above 160 causes the unit to convert this value to default (125). Default Value: 125 (1V) Cellocator Programming Manual Page 135 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 136: Averaging Factor For Shock Input

    1 to 0. In case this input is inverted, it will mean generation of the alert upon disconnection of this input from (-). Default Value: zeros – disabled (0 Cellocator Programming Manual Page 136 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 137: Reporting Signal Rising On Shock Input

    Name in Programmer: Assigned Function Description: This field enables assignation of certain functionality to a Panic input. Function Description Comment number Use as a GP input (default) Reserved Cellocator Programming Manual Page 137 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 138: Inverting Panic Input

    Value span: 57 (0.3V) to 240 (3V). Any measured value below 57 or above 240 causes the unit to convert this value to default (200=2.5V). Default Value: 200 Cellocator Programming Manual Page 138 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 139: Averaging Factor For Panic Input

    0 to 1. In case this input is inverted, it will mean generation of the alert upon connection of this input to (-). Default Value: zero – disabled (0 Cellocator Programming Manual Page 139 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 140: Power Events

    The unit will trigger “Main Battery OK” alert if the measured level of the main power will be higher than the value programmed in Main Power Low Threshold High Level. Data format: 8-bit unsigned, Cellocator Programming Manual Page 140 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 141: Geo-Fences

    Configuration description . byte Latitude Centrum Longitude Centrum bytes 1,2 and 3 Displace- Displace- ment ment Address Fence 0 2496-2512 Fence 1 2528 2513- Fence 99 4080-4095 Cellocator Programming Manual Page 141 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 142: Format Of Geographical Perimeter

    Segment Byte 0 In order to set certain fence to be permanently active the start time shall be set to 0:00 and the end time to 24:00 Cellocator Programming Manual Page 142 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 143: Toe - Type Of Entry

    Generates trigger on entry and exit to a fenced zone. Transmission reason 191, Trigger's transmission-reason-specific data: Bits 0-6 is the index of the slot. Most significant bit (bit Cellocator Programming Manual Page 143 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 144: No Modem Zone

    Trigger's transmission-reason-specific data is the index of latest slot that changed its status to violation state. Discrete context mode (fence logic = 1): Cellocator Programming Manual Page 144 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 145: Geo-Fence Violation Filter

    GPS fix is finally achieved Default value: 0 – Do not ignore violations on boot Cellocator Programming Manual Page 145 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 146: Control Of Geo-Fence Alters (Events And Distress)

    Description: If this bit is enabled the unit will generate an alerts upon violation of Geo Hot Spot Type of Geo-Zones. Default value: 0 – both Disable 11.2.4.5 No Modem Zone Entry Address: 1004, bit 4 1005, bit 4 Cellocator Programming Manual Page 146 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 147: Geo-Fence Priority

    When the priorities of overlapping Geo-Fences are different, the unit considers only the boundary of the highest priority Geo-Fence: Priority 1 Priority 1 Priority 2 Priority 2 Cellocator Programming Manual Page 147 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 148 Cellocator Programming Manual When the priorities of overlapping Geo-Fences are equal, the unit considers them as one Geo-Fence with common boundaries: Priority 2 Priority 2 Priority 2 Cellocator Programming Manual Page 148 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 149: Towing Detection And Towed Mode (Supported On Cello And Cr Families And Ct-Lte-Power)

    Idling (lack of movement) is detected for longer than defined in "Towing Detection and Towed Mode Time Filter" (address 137). In this case the unit will send Towing Mode Stop event (TR8/STR2). Cellocator Programming Manual Page 149 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 150: Enable Towed Mode

    Description: These parameters allow to enable Towed Mode Start-Stop events (TR8, STR1 or 2) upon entrance or exit to or from Towed Mode. Default value: 0 – Disable Cellocator Programming Manual Page 150 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 151: Cellotrack

    Enable Distress on Peeking - If this bit is enabled (‘1’), then 20 to 30 seconds before the end of the COM-Location glancing the unit will trigger a distress session, in form of Cellocator Programming Manual Page 151 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 152 Time Event Time Event Time Event TE Timeout Communic. Stop events when GPS peeking is enabled GPS power Programmable time (60 sec by default) GPS Fix received Cellocator Programming Manual Page 152 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 153: Cellotrack Configuration 2

    RC. Such a management is significantly improving an accuracy of the self clock, although increases current consumption by 3%-5% percent. It is recommended to activate FixTime Cellocator Programming Manual Page 153 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 154: Enable Extended Charging Temperature Range

    GPIO functions as Output only (STD IMMOBILIZER) GPIO functions as Output. The output actual state will be mirrored via the input. GPIO control 2 Description GPIO disabled Cellocator Programming Manual Page 154 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 155: Cradle Mount Power Save (Cellotrack Only)

    Resolution: seconds Data range: 40-80 seconds (any value lower than 40 will be mean 40, any value higher than 80 will mean 80) Default Value: 60 seconds Cellocator Programming Manual Page 155 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 156: Activation/Deactivation Procedure Options

    The device enters a Non-Activated state request. The device enters a Non-Activated until the next operation starts. state until the next operation starts. Cellocator Programming Manual Page 156 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 157: Gps-Based Start Event Enable (Non Cellotrack T Variants Only)

    If this bit is cleared then legacy functionality will be maintained: the start report will be sent only based on the accelerometer. Default value: 0 – normal procedure (accelerometer based) Cellocator Programming Manual Page 157 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 158: Gps-Based Movement Timeout (Non Cellotrack T Variants Only)

    Distress GPRS or SMS GPS acquired or timeout Max GPS On Extra GPS The trigger The Distress session, triggered during sleep mode, is managed according to the following scenario: Cellocator Programming Manual Page 158 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 159: Glancing At Specific Time (St Glancing)

    The ST transmission is generated with the transmission reason of Glancing (252, Transmission Reason Specific Data 1). If both regular, interval-based glancing and ST glancing are enabled they both will be maintained simultaneously and independently. Cellocator Programming Manual Page 159 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 160 Setting the "ST Hour" to a value bigger than 23, will cancel the ST Glancing. Setting the "ST Minutes" to a value bigger than 59, will cancel the ST Glancing. Cellocator Programming Manual Page 160 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 161: Radio-Off (Cellotrack And Cellotrack Power)

    3.6 Volts or below for 30 consecutive seconds. The early Radio off message will inform the server side that the unit’s battery voltage is very low and that Radio off mode is about to start soon. Cellocator Programming Manual Page 161 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 162: Advanced Glancing (Peeking): Cellotrack And Cellotrack Power

    The new glancing-time will be used in the next glancing period or if distress or Active Logged event will be triggered. Cellocator Programming Manual Page 162 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 163 For example, when charging power is connected and the temperature is out of charging range the battery will not be charged, in this case we are in NotCharging state. Charger Power Charging Logic Status Charging Mode source State Cellocator Programming Manual Page 163 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 164: Cradle Tamper Events Definitions

    (Active) = outside the cradle. But the terminology of "Rising" is removal from cradle and the term "Falling" is insertion to the cradle. Default Value: zeros – Disable (0 Cellocator Programming Manual Page 164 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 165: Cellotrack Power

    0 – Disable extended charging 1 – Stop charging 1 – Enable temperature range" parameter 1 – Allow battery charging in a (-20) - (+60) deg temperature range Cellocator Programming Manual Page 165 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 166: Slow Charging In Extreme Temperatures

    A summarizing table for all the possible combinations: Slow charge Charging Enable Enable in extreme Stop upon extended Additional temperatures Battery Full charging Extended enable detection Charging Cellocator Programming Manual Page 166 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 167: Cellotrack-Phoenix (Lv300P Only)

    An internal special variant of CelloTrack-LTE-Power with support in delivering power and communication with the Phoenix sensor. 14.3.1 Phoenix Sensor Feature Enable Address: 229 bit 0 Description: When Phoenix Feature enabled the unit will operate as follows: Cellocator Programming Manual Page 167 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 168: Important Note

    (during logical Ignition STOP only) When disabled, the unit will operate as follows: Phoenix Sensor Periodic_Check cycle will be operated with no dependency to logical Ignition State (STOP/START). Cellocator Programming Manual Page 168 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 169: Phoenix Sensor Presence-Status-Change Type-11 Event

    Time Limit of Periodic Sampling When External Power Disconnected Address: 228 Bits 0-4 Description: This parameter defines the time limit of periodical samples when external power is disconnected. (0=No time limit). Resolution: 1 day Cellocator Programming Manual Page 169 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 170: Asynchronous Sample - When External Power Is Disconnected

    The purpose of this project is to connect between the Smart Trailer system in Hyundai tracks and the PointerConnect application. The benefit: the sensor info will be deployed to the backend operator on duty. Cellocator Programming Manual Page 170 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 171: Enable Hyundai Ht Logic

    If not moving – once a day (24 hours after last EOD; any BOD resets this counter) If moving – EOD, EOD and every Intransit report (by default 15 minutes). The LV300p will Cellocator Programming Manual Page 171 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 172 LV300, the unit will use Hyundai logic and ignore/disable Fenix. Value: Feature disabled Plain Event Active event Forbidden Default: 0 (Disable) Cellocator Programming Manual Page 172 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 173: Lv300- Power Preservation Mode

    LV750 and making SG calibration. LV300 will leave installation mode upon the first time product being powered from external Cellocator Programming Manual Page 173 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 174 Fence” feature. Once Installation zone defined as Geo-fence, after powering up the LV300, “Zeppelin Mount/Unmount” feature (which is consuming lots of power) will stay deactivated while device located in the installation zone. Cellocator Programming Manual Page 174 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 175 5 sec with external power) 2. OTA command entering Preservation mode Leaving condition- 1. External power connection available (12V/24V) to LV300hard coded time filter of consecutive 5 sec with external power) Cellocator Programming Manual Page 175 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 176 C+ connection according to PL (default every one week) If unit will detect BOD or being externally powered (12V/24V), it will leave storage mode. Entry condition- Cellocator Programming Manual Page 176 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 177 Only one daily ST glancing event will be generated in order to taking position and check for cellular communication availability, iii. Once connectivity back unit will return to Preservation mode. Cellocator Programming Manual Page 177 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 178: Lv300 Preservation Mode Activation And Configuration

    Unit operational mode cross reset: upon SW reset (or PL upgrade), unit will remain in same operational mode before the reset. 14.5.1 LV300 Preservation mode activation and configuration Address: 919(bits 0-6) Description: Preservation mode activation and configuration bits Cellocator Programming Manual Page 178 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 179: Time Between Periodical Listen Event Transmission In Lv300 Preservation

    BOD state while in Preservation mode. A BOD state is the state between BOD and EOD. Resolution: 5 Minutes Data Range: 5-1275 Minutes (0=Disable) Default Value: 60=min 14.5.4 Cellocator Programming Manual Page 179 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 180: Cellotrack Nano

    RF communication) MultiSense (Remote sensor with short- Cellular link CelloTrack range RF communication) Nano (with its internal sensors) MultiSense (Remote sensor with short- range RF communication) Cellocator Programming Manual Page 180 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 181: System Modes

    "Hibernation Mode Delay" parameter is maintained (the default is 2:40 minutes). GSM periodic glancing GNSS peeking (legacy) Nano take location interval Nano take location interval GNSS peeking (improved modes) Extra GNSS peeks and log it Cellocator Programming Manual Page 181 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 182: Sampling Rate

    There is some ratio between location and full sensors glancing, as described in section 15.2.1. Layer-2: Movement related events When the unit is moving (in motion state, i.e. ignition-ON state): Cellocator Programming Manual Page 182 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 183: Usb

    The charging current in this case is ~330mA, so a complete charge will take less than 5 hours. 15.4.3 Charging Modes The unit has 2 modes of charging: Cellocator Programming Manual Page 183 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 184: Power-Bank Keep Alive Pulsing

    This is not reflecting the power bank level which is usually only displayed on its own LEDs. 15.4.4.1 Power bank keep alive pulse rate Address: 1858 Cellocator Programming Manual Page 184 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 185 In inactive state of the system, the LEDs shall function as before. This is to improve current consumption when working with external batteries and power- banks. 0 = Disable 1 = Enable Cellocator Programming Manual Page 185 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 186: Sensors

    Default value: 0 = Disable 15.5 Sensors HW Block Accelerometer Ambient Pressure Accurate Humidity Light Sensor Temperature Sensor (of the Function Sensor Sensor MultiSense) /Feature Tilt tamper Orientation change Man-down Cellocator Programming Manual Page 186 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 187: Use Of Iir Filters

    For example, if IIR7 is configured (Factor=7), after 7 samples the filtered value will accumulate 66% of the 100% change in value. After 14 samples 88% and after 21 samples 96% etc. Cellocator Programming Manual Page 187 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 188: Accelerometer

    This interval is from the last fix or timeout of "Max GPS on time", and it is parallel to the legacy "GPS off time" parameter. BT SIG certification is currently in the product evolution process Cellocator Programming Manual Page 188 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 189: Gps Warm Start

    (if enabled, and regardless of type-0 legacy event configuration) as a Logged Event, as an "Active Log event" or as both, in the following way: Address 540: TR=3 TR=2 TR=1 TR=0 Cellocator Programming Manual Page 189 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 190: Tilt Tamper

    + ������������ �� ��−1 ��−1 �� When Avg is the filtered value (filter output). The subtraction of these 2 filters outputs is compared with the configurable threshold. Cellocator Programming Manual Page 190 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 191 33x, and in CelloTrack-T units from FW version 61c. Type 11 messaging is not applicable for Cello-(CAN)IQ and CelloTrack-T. 15.8.4.2 Tilt-Tamper Angle Change Threshold Address: 2045 Description: Tilt threshold in degrees. Cellocator Programming Manual Page 191 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 192: Accelerometer Based Impact / Free-Fall Detection

    Bit 6 Bit 5 Bit 4 Bits 0-3 Default value: 0x00 = All disabled NOTE: If none of these bits are enabled, then the entire feature is disabled. Cellocator Programming Manual Page 192 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 193: Orientation Change

    Orientation change messaging Reserved Type-11 Type-0 Logged "Active log Logged Distress event" Bit 7 Bit 6 Bit 5 Bit 4 Bits 0-3 Default value: 0x00 = All disabled Cellocator Programming Manual Page 193 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 194: Package Open/Close Events

    (for both Nano and MultiSense) Type-11 Type-0 "Active log Logged Logged Distress event" Bit 7 Bit 6 Bit 5 Bit 4 Bits 0-3 Default value: 0x00 = All disabled Cellocator Programming Manual Page 194 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 195 Data range: 2÷63 Second (value of 0 will disable the entire feature in the Nano only. Value of 1 is illegal and should not be set) Default value: 0x02 = Fastest response Cellocator Programming Manual Page 195 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 196: Analog Source Selection

    0xFE – MCU internal (temperature only) 0xFF – Reserved Default value: 0xFD = High accuracy or specialized sensors of the Nano 20 Cellocator Programming Manual Page 196 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 197: Sensor Type

    Full system (16 humidity sources + 17 temperature sources), each queue will be 35 samples.  10 temperature sources, each queue will be 48 samples.  13 humidity sources + 14 temperature sources, each queue will be 42 samples. Cellocator Programming Manual Page 197 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 198 2 sampling times it will wait 2 sampling time periods.  If the Alert time is more than 2 sampling times the unit will wait the defined sampling time. Cellocator Programming Manual Page 198 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 199 Data range: 0÷255 = 0÷510. Valid range is 2÷510 seconds and must be < than "Temperature alert time", otherwise the entire logger is disabled. Default value: 0x1E = 60 seconds Cellocator Programming Manual Page 199 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 200 15.8.9.5 Alert Temperature Sampling Rate Address: 2070 Description: Time for a violation to become an alert, and also reverting from non- violation to non-alert. Resolution: 2 seconds Cellocator Programming Manual Page 200 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 201 Note: When the bits of type-11 are enabled, the message used to convey the event is module 40 (and not module 28). Default value: 0x00 = All disabled Cellocator Programming Manual Page 201 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 202 A buffer can only be transmitted via type-11 messages. The retransmissions are also sent (if enabled) over type-0 messages with current single measurements only. Resolution: 1 minute Data format: 1 byte, decimal value Data range: 0÷255 minutes Cellocator Programming Manual Page 202 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 203 These bits enable (=1) or disable (=0) the messaging for the temp. & humidity idle transmission event configuration. Temp. & humidity idle transmission event configuration Type-11 Logged "Active log event" Bit 7 Bit 6 Default value: 0x00 = All disabled Cellocator Programming Manual Page 203 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 204: Buzzer Configuration

    Default value: 1 = Enable (according to time only) 15.8.10 Buzzer Configuration 15.8.10.1 Buzzer Enable Bits Address: 2077 bits 1-7 Description: These bits enable (=1) or disable (=0) the various buzzer indications. Cellocator Programming Manual Page 204 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 205: Leds Configuration

    15.8.11 LEDs Configuration Address: 2079 Description: These bits enable (=1) or disable (=0) the various LED indications. Panic LED Check-in LED feedback feedback Bits 7 Bit 6 Cellocator Programming Manual Page 205 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 206: Check-In_Out Configuration

    Check-in_out messaging Reserved Type-11 Type-0 Logged "Active log Logged Distress event" Bit 7 Bit 6 Bit 5 Bit 4 Bits 0-3 Default value: 0x00 = All disabled Cellocator Programming Manual Page 206 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 207: Work-Id (Activation) Messaging

    Address: 2082 Description: For each type of event the following can be configured:  Whether the event activates the buzzer.  Whether the event activates the LEDs. Cellocator Programming Manual Page 207 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 208: Ble Block

    MultiSense units. The data that will be reported include the "MAC address," "battery level, "RSSI", "TX-reason", "FW version", "BOM mask" and "Sensors mask" fields. Cellocator Programming Manual Page 208 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 209 Description: These bits enable (=1) or disable (=0) the messaging for the Guest and Tag mode reports. Tag or Guest MultiSense event messaging (Both for Guest and Tag modes) Type-11 Cellocator Programming Manual Page 209 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 210 Data range: 0÷65535, valid range is 2÷ 43200 = 4÷86400 seconds, but it is not recommended to set it below 20 seconds. Default value: 0x0E10 = 3600 seconds = 1 hour Cellocator Programming Manual Page 210 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 211 Note: This parameter will be rounded to the closest sampling time units. Resolution: 1 minute Data format: 1 byte, decimal value Data range: 0÷255, valid range is 1÷ 255 minutes Default value: 0x02= 2 minutes Cellocator Programming Manual Page 211 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 212: Dry Contact Input Mode

    MultiSense. For more details, look at the wireless protocol doc. Note that if using the MultiSense data-logger, then this module becomes mandatory. Data range: 0= Disable, 1= Enable Default value: 0= Disable Cellocator Programming Manual Page 212 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 213: Prevent Power Button From Shutting Down (Nano)

    Periodic Transmission (in battery saving mode) - Type-0 Address: 526, bit 6 Description: This parameter enables to send only logged events of type "Periodic Transmission (in battery saving mode)" in type-0. Cellocator Programming Manual Page 213 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 214 Sending this event in Type-11 (encapsulated) either in addition to type-0 or instead of it, the bits 4-5 in address 542 should be set accordingly. Data Range: 1 - Enable, 0 - Disable. Default Value: 0 – Disable. Cellocator Programming Manual Page 214 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 215: Cellotrack 10Y/Solar/Lte

    2 LEDs Battery Fuel Gauge Micro USB Connector Non Rechargeable Front Button + Li Battery Tamper Switch (5 Cells x 8.5Ah) System Step Up DC2DC 3A Power Cellocator Programming Manual Page 215 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 216 Comparator Tamper Switch Non Rechargeable Battery Fuel Gauge Li Battery DC2DC (4 Cells x 8.5Ah) Power Pass Super Caps Solar Panel DC2DC DC2DC (4 x 200F) Comparator Cellocator Programming Manual Page 216 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 217: Sensors

    Address: 2065, bits 5-7 Description: One of the measured sensors can be selected and routed to one of the type-0 legacy analog channels. Data Range: Enum Description Cellocator Programming Manual Page 217 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 218: Accelerometer

    67/69k respectively). Thus, their external interfaces are different than those of CelloTrack Nano (cap sense buttons, microphone and buzzer are not assembled on the unit, and GPIOs are not available). Cellocator Programming Manual Page 218 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 219: Leds

    5 seconds LED Off interval will separate between each cycle. GSM Zone GPS Zone GSM Zone GPS Zone GSM Monitoring Zone: Status Blinking pattern GSM Off Cellocator Programming Manual Page 219 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 220 Cellocator Programming Manual Not registered to GSM/No SIM Registered in Home GSM network (not attached to GPRS) Cellocator Programming Manual Page 220 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 221 Cellocator Programming Manual Registered in Roaming GSM network (not attached to GPRS) Attached to GPRS/home Cellocator Programming Manual Page 221 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 222 Cellocator Programming Manual Attached to GPRS/roaming GPS Monitoring Zone: Status Blinking pattern GPS Off GPS is unplugged/faulty Cellocator Programming Manual Page 222 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 223 Cellocator Programming Manual GPS communicating, but not navigating GPS is in navigation mode Cellocator Programming Manual Page 223 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 224 0 - Disable 1 - Enable Default value: in CT 10Y: 1 – Enable In all others products: 0 - Disable Cellocator Programming Manual Page 224 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 225: Front Button

    Distress Button Active event (TR 70) will be sent (if enabled). Note: Consecutive presses will be ignored, if started before the SYS LED indication of the previous press/sequence ended. Cellocator Programming Manual Page 225 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 226: Tamper Switch

    Address: 402, bit 4 Description: When this bit is enabled, the unit will add fresh GPS stamp to the last chunk of FCAM/LV-75x files in the following way. Cellocator Programming Manual Page 226 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 227 1 - Enable Default: 0 (Disable) 16.2.4.5 Add Module 41 to Module 28 Sourced from BLE (MS) Event Address: 2367 Bit 1 Description: If this parameter is enabled then: Cellocator Programming Manual Page 227 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 228: Satellite Modem (Ct-Solar V3)

    Satellite modem (CT-Solar V3) The special variant of the CT-Solar called LV550 includes an Iridium satellite modem as a backup link for the cellular link towards the server. Cellocator Programming Manual Page 228 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 229: Enable Satellite Modem

    Valid range: 0-255 (Disable, 5 min - 1275 min (= 21:15 hours)) Default value: 72 (360 minutes = 6 hours) 16.3.4 Enable send via satellite Address: 4130-4161 Cellocator Programming Manual Page 229 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 230: Enable Via Satellite For Native Type-11 Events

    MultiSense MultiSense Unused Open/close Reserved Provisioning door/window via satellite via satellite Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Cellocator Programming Manual Page 230 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 231: Maximum Satellite Modem On Time

    Default for byte 26 of OTA Message 0 CT LTE: Default for byte 29 of OTA Message 0 CT 10Y: Default for byte 28 of OTA Message 0 Cellocator Programming Manual Page 231 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 232 Description: The unit will trigger Battery Low event if the measured SOH (State of Health) of the main battery will be less (or equal to) then value programmed in this parameter. Resolution: 1% Data Range: 0-100% Default Value: 15% Cellocator Programming Manual Page 232 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 233: Battery Status Manual Check

    This mode is designed to preserve this energy of the primary battery and enter an especial Battery Preservation Mode, as described below. Note: Battery Preservation Mode is only applicable in BOD/EOD mode Cellocator Programming Manual Page 233 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 234: Timeout To Battery Preservation (Lv5Xx Only)

    This value will determine the timeout between detection of low supercap voltage (<2.4V) and entrance into Battery Preservation mode. This timeout can only be triggered during EOD period (after EOD). Cellocator Programming Manual Page 234 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 235: Battery Replacement Sequence

    System Tracking Mode Address: 2040, bits 6-7 Description: This parameter allows to set the tracking mode. It is stronger than the configuration in the legacy "Enable live Tracking" bit. Cellocator Programming Manual Page 235 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 236 Stops the periodic Theft Mode transmissions.  Returns to its "System Tracking Mode" configuration.  If the "System Tracking Mode" is configured to BOD/EOD Glancing, the current BOD/EOD state is restored. Cellocator Programming Manual Page 236 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 237 Server glancing command received? Send ACK message Periodic Periodic Stop Periodic Glancing Start Periodic Glancing Glancing Command Type Glancing (Theft Mode) (Theft Mode) Stop Start Go to Cellocator Programming Manual Page 237 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 238: Bod Distance Filter

    A BOD state is the state between BOD and EOD. Resolution: 5 Minutes Data Range: 5-2555 Minutes (0=Disable) For CT-Solar the recommended setting is at least 15 minutes. Default Value: 0=Disable Cellocator Programming Manual Page 238 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 239: Additional Tsrs Every

    Description: When this parameter is set to '1' the idle transmission will not initiate a GPS take location attempt. 0 = Take location 1 = Don't take location Default value: 0 = Take location Cellocator Programming Manual Page 239 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 240: Ble Wake Up Period

    Off Battery Voltage Threshold” (on address 916) 2) drive (20s activity) or power in last 2h. (Zeppelin) Default value: 0 - Disabled 16.5.12 Time between periodical Listen Event Transmission Address: 403 Cellocator Programming Manual Page 240 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 241: Time Between Periodical Events During Bod On Battery (Ct-Solar Only)

    (under PL folder of "03 Time&Trip events \Comm.Idle events\Listen Interval\Listen Interval When Moving & Outside Working Hours\") 0 - Disable 1 - Enable Default Value: 0 - Disable Cellocator Programming Manual Page 241 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 242: Gsm Peeking Time - When Outside Geo-Fence

    1.1.1 Working Hours for eTracking (Theft Mode) Interval When Moving PL Parameter Address Table: Start Hours Start Minutes Duration Sunday 4171 4172 4173 Monday 4174 4175 4176 Cellocator Programming Manual Page 242 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 243: Gps Stationary Anti-Drift Filter

    Default value: 0 - Disable Note: Working Hours is in UTC time standard. Each day of the week have a separate PL folder. 16.5.19 GPS Stationary Anti-Drift Filter Address: 659 Cellocator Programming Manual Page 243 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 244: Further Details

    5) The valid value span is between 1 second and 35 sec shorter then "Max GPS On Time". If configured value is higher then this - the unit will limit this number to 35 seconds shorter then "Max GPS On Time" automatically. Cellocator Programming Manual Page 244 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 245: Flow Chart

    Movement Start detected? Unlock GPS coordinates Default: 0 (Disable) Recommended value - 80 GPS samples. This parameter shall be located in PL folder "08 CelloTrack family\General\" Cellocator Programming Manual Page 245 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 246: Zeppelin - Mount/Unmount Detection

    4. It should be followed by another period of “silence”, or “no movement” of at least 5 seconds. If one the conditions above will be violated, the SNR after Impact will not start. Cellocator Programming Manual Page 246 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 247: Enable Mount/Unmount By Gps Snr Event

    Module-119) upon Mount or Unmount detection by GPS SNR comparison. Note, that there are different thresholds for Mount and Unmount detections. Data range: 0 - Disable 1 - Active Log Event 2 - Logged Cellocator Programming Manual Page 247 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 248: Snr Delta Threshold For Zeppelin Mount/Unmount Detection

    GPS SNR level is higher then the threshold defined in this parameter 2. A difference in SNR is greater than PL parameter "SNR Delta Threshold" (on address 1441-1442) Resolution: 0.01 dB Cellocator Programming Manual Page 248 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 249: Zeppelin Postpone Mount Event Until Short Drive Verification

    Note: This feature is expiremental and not reccomended for use in prodcution. Data range: 0 - Disable 1 - Active Log Event 2 - Logged Default value: 0 - Disable Cellocator Programming Manual Page 249 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 250: Zeppelin Mount By Gps Snr During Drive

    2. The difference in SNR from previous staty state is greater than defined in PL parameter "SNR Delta Threshold" (on address 1441-1442) 0 - Disable 1 - Enable Default: 0 (Disable) Cellocator Programming Manual Page 250 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 251: Zeppelin Mount/Unmount Only Outside Geo-Fence

    3.54v = 20%, 3.57v = 25%, 3.61v = 30%, 3.64v = 35%, 3.68v = 40%, 3.71v = 45%, 3.75v = 50%, 3.78v = 55%, 3.82v = 60%, Cellocator Programming Manual Page 251 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 252 4.13v = 100%. Resolution: 0.01647[V] Default Value: 3.7 (=3.70 [V] in PL window value. Equal to 45%) This parameter is located under folder "08 CelloTrack family\BOD and EOD Criteria\" Cellocator Programming Manual Page 252 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 253: Wireless Ble Sensors

    Nano. If "Tag mode" is enabled here, the Nano unit will only report on existence (reception of advertisements) of unpaired MultiSense units, not reading their sensors. Cellocator Programming Manual Page 253 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 254: Operation

    If enabled here, a beep is heard for every elapsed second in the first 4 seconds; if the check-in buzzer enabled bit is set or not "Dual short beeps" after the 5 second (0.5 Cellocator Programming Manual Page 254 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 255: Unpairing Process

    (1 second each, with OFF time 200mS between them) and with the orange LED turning off. If no approval was given, it is possible to reattempt the procedure. Cellocator Programming Manual Page 255 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 256: Sensors

    This sensor is binary. It recognizes if a strong enough magnetic field exists or not. If enabled here, upon any change of state, it triggers an interrupt and an asynchronous wake-up and Tx cycle. Cellocator Programming Manual Page 256 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 257: Parameter Descriptions And Notes

    Any change of state is reported immediately to the Nano. 17.4.2.1 MultiSense Open/Close Door/Window Event Messaging Address: 2354 bits 4-7 Description: These bits enable (=1) or disable (=0) the messaging for the MultiSense Open/Close door/window feature. Cellocator Programming Manual Page 257 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 258: Ble Pairing Time Window

    MultiSense MAC address HW_ID 9 configuration bytes byte per MultiSense (6 bytes) 2236÷2241 2332 2092÷2100 2242÷2247 2333 2101÷2109 2248÷2253 2334 2110÷2118 2254÷2259 2335 2119÷2127 2260÷2265 2336 2128÷2136 Cellocator Programming Manual Page 258 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 259 Keep-alive only and upon violations Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default value: 0x00 = All disabled Cellocator Programming Manual Page 259 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 260 Description: MultiSense Temperature upper limit threshold. Resolution: 1ºC Data format: Signed (2's complementary) decimal value Data range: 0÷255, valid range is 0÷80, -1÷-40 = -40÷80 ºC Default value: 0x00 = 0ºC Cellocator Programming Manual Page 260 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 261 Description: MultiSense Impact/Free-fall event threshold in g (earth gravity) units. Recommended values for Impact mode is >1.5g. Recommended values for free-fall mode is <0.7g. Resolution: 63mg (full scale is ±8g) Cellocator Programming Manual Page 261 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 262: Advanced Ble Settings

    2-3 and 9 byte These bits and bytes are empty and reserved (=0x00). 17.5 Advanced BLE settings 17.5.1 Data logger full processing Address: 2084 bit 6 Cellocator Programming Manual Page 262 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 263: Group-Id

    (3 Sec) to prevent human intervention in the connection process. Data range: 1-2147 seconds (values above 2147 will be treated as 2147), 0=Infinite (unlimited time) Default value: 0x003C = 60 Seconds Cellocator Programming Manual Page 263 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 264: Multisense Timers Multiplier

    This feature can be helpful to deploy a large number of MultiSense/CelloSense units and force a certain configuration upon all of them. Please use this feature with great caution and for a limited time only! Cellocator Programming Manual Page 264 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 265: Ble Rssi For Auto Ms/Cs Config

    Description: This parameter defines a minimum measured value of BLE RSSI to proceed with auto- Pushbutton / Magnet of MS/CS is triggered MS/CS config in case of Cellocator Programming Manual Page 265 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 266: Cellosense

    The magnetic sensor can be configured to serve as the pushbutton or as normal magnet sensor.  Easy to install within harsh environments via two metal tie-wraps or two supplied screws. Cellocator Programming Manual Page 266 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 267: Concept Of Operation

    This algorithm is based on 2 operational zones: Zone-1 is defined with a keep-in geo-fence(s) (as described in 17.6.13 below) and usually should be set to the whereabouts of the main warehouse(s). And Zone-2 is everywhere else. Cellocator Programming Manual Page 267 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 268 TR=Zone_2_stationary_detected and keep transmitting in the “Zone-2 moving Tx rate” but with TR=Zone_2_stationary_after_movement  If a new movement is detected meanwhile, it will transmit once TR=Zone_2_new_movement_detected and revert to Moving-state, but if no Cellocator Programming Manual Page 268 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 269: Magnetic Sensor As Pushbutton

    Zone-2 moving Tx rate Address: 1885 till 1886 bit 3 (12-bits) Description: This parameter sets transmission rate when moving in Zone-2. Resolution: 5 Seconds Valid values: 0-4095 (0-20475 Sec) Cellocator Programming Manual Page 269 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 270: Zone-1 Phase-A Lifting Motion Activity Total Time

    2 - 10 Hz 3 - 25 Hz 4 - 50 Hz 5 - 100 Hz 6 - 200 Hz 7 - 400 Hz Default value: 4 (50 Hz) Cellocator Programming Manual Page 270 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 271: Acceleration Motion Pulse Width For Zone-1 Phase-A

    Valid values: 4-255 Seconds (if set to 0-3 it is forced to be 4) Default value: 5 Seconds 17.6.12 Enable LV/Nano to CS connections after lifting detection (Zone Address: 1898, Bit 3 Description: Cellocator Programming Manual Page 271 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 272: 2Nd Alternative Settings For Zone 2

    The zone is determined by the unit, according to the geo-fences and stored in the MultiSense/CelloSense so if it leaves the area it still keeps this info, until set by another unit. Cellocator Programming Manual Page 272 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 273: 2Nd Alternative Relax Timer

    Data range: 0÷65535, valid range is 2÷43200 = 4÷86400 seconds, but it is not recommended to set it below 20 seconds. Default value: 0x2A30 = 21,600 seconds = 6 hours Cellocator Programming Manual Page 273 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 274: 2Nd Alternative Violation Timer

    0 = No multiplier = Legacy resolution where each bit is 2 Seconds. 1 = Minutes = Multiplier of 60, so each bit is 2 minutes 2-3 = Reserved Default value: 0 = No multiplier Cellocator Programming Manual Page 274 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 275: 2Nd Alternative Motion Detection Start Filter (Global)

    Description: After sensor stopped moving, it will still transmit in high rate until this timeout expires. Resolution: 1 Minute Valid values: 0-255 Minutes Default value: 20 Minutes Cellocator Programming Manual Page 275 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 276: Tractor/Trailer Matching

    It is also possible to enable Matching / Unmatching on the fly: changing the matched Trailer and Tracktor without a need to wait for status change to “Unmatched”. Cellocator Programming Manual Page 276 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 277: Allow Pairing To The Cellosence Even If Already Paired

    Otherwise, if disabled, the CelloSence will have to “loose” first the paired Trailer (LVx00), issue the “Unmatch” event and only then wait for the a new Trailer upon new movement detection. 0 – Disable Cellocator Programming Manual Page 277 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 278: Reduce Tx Rate During Long Movement Timeout

    Tractor/Trailer matching activity (Type 11 module 30, appropriate TX reasons). 0 – Disable 1 - Enable Default value: 0 – Disable This parameter is located in directory - 09 MultiSense related global settings\Match Trailer\ Cellocator Programming Manual Page 278 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 279 Cellocator Programming Manual Cellocator Programming Manual Page 279 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 280: Cble

    Description: This parameter sets the transmit power output level of the CBLE according to BLE type assembled on Product : CSR1010 CBLE: 0= +8dBm (Maximal) 1= +6dBm 2= +2dBm 3= -2dBm 4= -6dBm 5= -10dBm Cellocator Programming Manual Page 280 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 281: Advertisement Duplications Filter

    (i.e. not a paired MS/CS while unit is in Tag mode). 0=Disable filter Resolution: 50 mS Data range: 1÷255 = 50mS-12.75 Seconds , 0=Disable filter Default value: 0 (Disable) Cellocator Programming Manual Page 281 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 282: Health Monitor

    This feature designed for debugging, testing and overall product maintenance in field\lab. It can help as fleet health monitoring tool for customers or as remote tool for PowerFleet to track & manage BETA test or large customer fleet , without need of customer intervention.
  • Page 283 End collection- UTC Time – hour End collection- UTC Time – Day End collection- UTC Time – month End collection- UTC Time – year (-2000) (e.g. value of 22 = year 2022) Cellocator Programming Manual Page 283 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 284: Health Report For Entity

    Default Value: 0= Disable 18.1.2 Health Report period Address: 922 Description: Health Report period – between 1 to 255 days. Resolution: 1 day Data Range: 1-255 Default Value: 30 days Cellocator Programming Manual Page 284 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 285: Health Report -Diagnostic Start Time

    (0-255 BLE TX reasons ) and can be used for statistic and Quality of Service(configured VS received) . Data Range: 0-255 Default Value: 22 (none in used) Cellocator Programming Manual Page 285 of 286 Copyright © 2021 by PowerFleet Inc.
  • Page 286: Health Report -Ble Tx Reason 2

    (0-255 BLE TX reasons ) and can be used for statistic and Quality of Service(configured VS received) . Data Range: 0-255 Default Value: 22 (none in used) Cellocator Programming Manual Page 286 of 286 Copyright © 2021 by PowerFleet Inc.

Table of Contents