Sign In
Upload
Manuals
Brands
Particulate Systems Manuals
Laboratory Equipment
HPVA Series
Particulate Systems HPVA Series Analyzer Manuals
Manuals and User Guides for Particulate Systems HPVA Series Analyzer. We have
1
Particulate Systems HPVA Series Analyzer manual available for free PDF download: Operator's Manual
Particulate Systems HPVA Series Operator's Manual (124 pages)
High Pressure Volumetric Analyzer
Brand:
Particulate Systems
| Category:
Laboratory Equipment
| Size: 7 MB
Table of Contents
Table of Contents
5
1 Introduction
9
Conventions
9
Equipment Description
10
Controls and Connectors
12
Upper Front Panel
12
Sample Compartment
14
Rear Panel
15
Turning the Analyzer on and off
16
Main Menu
17
Starting and Exiting the HPVA Software
18
File Names
18
Specifications
19
2 Performing an Experiment
21
Preparing the Sample
21
Requirements
21
Cleaning the Sample Cylinder
22
Weighing the Sample
24
Assembling the Sample Holder
25
Degassing the Sample
27
Attaching the Sample Holder to the Analysis Port
32
Purging the System
35
Running the Experiment
40
Viewing the Experiment
43
Displaying the Isotherm
43
Adjusting Flow Valves
46
Definitions of Fields in the System Windows
47
Define New Experiment Window
47
Define Run Window
49
3 Viewing Experiment Results
53
Running the Macro
53
Read Me Tab
54
Gases Tab
54
Parameters Tab
55
Compile Error Message
57
Displaying Experiment Data
58
Read Long Data File
58
Read Short Data File
60
Read Helium Data File
65
4 Using the Manual Control Window
67
Description
67
Controlling Valves
68
Setting the Sample Bath Temperature
69
5 Configuring the System
71
Calibrating the System
71
Changing the Data Directory
71
Configuring the Hardware
72
System Configuration Window
72
Instrument Tab
72
Tasks Tab
73
Analog Input Tab
74
Analog Output Tab
75
Instrument Options Tab
76
Dosing Tab
78
Adsorption Tab
80
Free Space Tab
81
6 Troubleshooting and Maintenance
83
Troubleshooting
83
Resetting the Pressure Limit
86
Entering the Slope
87
Replacing Degas and Analysis Port O-Rings
88
Connecting Gases
88
Guidelines for Connecting Gases to the Analyzer
88
Required Items
89
Disconnecting the Depleted Bottle
89
Connecting a Replacement Gas Bottle
90
Adjusting the Metering Valves
93
7 Ordering Information
97
Error Messages
99
Performing a Cryogenic Analysis
103
Description
103
Measuring Free Space
104
Performing a Blank Tube Experiment
104
Displaying the Free Space
110
Preparing the Sample
111
Advertisement
Advertisement
Related Products
Particulate Systems NanoPlus
Particulate Systems NanoPlus-1
Particulate Systems NanoPlus-2
Particulate Systems NanoPlus-3
Particulate Systems Categories
Laboratory Equipment
Measuring Instruments
More Particulate Systems Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL