Sign In
Upload
Manuals
Brands
ParTech Manuals
Accessories
TurbiTechw2 LR
ParTech TurbiTechw2 LR Manuals
Manuals and User Guides for ParTech TurbiTechw2 LR. We have
1
ParTech TurbiTechw2 LR manual available for free PDF download: Instruction Manual
ParTech TurbiTechw2 LR Instruction Manual (34 pages)
Brand:
ParTech
| Category:
Accessories
| Size: 2 MB
Table of Contents
Table of Contents
3
1 Foreword
6
2 Introduction
7
Manual Conventions
7
Waterwatch² Trademark
7
Scope of Manual
7
External Sensors
7
3 Safety Precautions
8
General
8
Electrical Installation
8
Operating
8
Service and Maintenance
8
End of Life Disposal
9
4 The Sensor and Installation
10
Turbitechw² LR Sensor
10
5 Mechanical Installation
11
Operation Limits
11
Temperature
11
Pressure
11
Maximum Levels
11
Material Compatibility
11
Sensor Components
11
Transmitter Module
12
Receiver Module
12
Cleaning Module
12
Mounting & Installation
12
Process Connections
12
Sample Flow Rate
12
Sample Pressure
13
Optional Accessories
13
Optional Flow Verification Detector
13
6 Electrical Installation
14
Sensor Connections
14
Extending Sensor Cables
15
7 Sensor Configuration
16
Sensor Config
16
Sensor Status
16
Add Sensor
16
S:0X Turbitechw² LR (0-30)
17
S:0X Manual Clean
17
S:0X Info
17
S:0X Remove
17
S:0X Modbus Address
17
S:0X Clean Config
17
8 Measurement Configuration
19
Measurement Config
19
Measurement Status
19
Add Measurement
19
M:0X - Measurement Channel
20
M:0X Info
20
M:0X Title
20
M:0X Units
20
M:0X Set Zero
20
M:0X Set Cal
20
M:0X Averaging
20
M:0X Remove
20
M:0X Display Position
20
9 Calibration
21
Calibration Frequency
21
Equipment Required for Formazine Calibrations
21
Calibration Zero
22
Calibration Span
23
Span Calibration Using the Take Sample Routine
23
Take Sample
24
Sample Result
25
10 Maintenance
26
General Cleaning
26
Inspection
26
Dismantling the Sensor
26
Removing the Modules
26
11 Spares
27
Service Parts
27
12 Sensor Faults
28
Unstable Reading on Controller
28
Error Codes from 7300W² Monitor
28
Input High Limit/Low Limit
28
Over Range/Under Range
28
13 General Application Notes
29
Preparation of Formazin Turbidity Standard
29
Health & Safety Precautions
29
Method of Preparation
29
Preparation of Dilution's
29
Calibration
29
Storage Life
29
14 Technical Support
31
Returning Equipment for Repair
31
Advertisement
Advertisement
Related Products
ParTech ASLD2200
ParTech IL55
ParTech IL55BV2
ParTech OxyTechw2 GAL
ParTech SoliTechw2 IR Series
ParTech Categories
Measuring Instruments
Accessories
Touch terminals
Security Sensors
Lighting Equipment
More ParTech Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL