Table of Contents
Table of Contents
3
Section 1.0 General Information
5
Principle of Operation
5
Typical F - 4300 Flow Meter Installation
5
Standard Features and Specifications
6
Model Numbering Codification
8
Additional Hardware that May be Required
9
Working Environment
9
Maintenance
9
Serial Number
9
Section 2.0 Unpacking
10
Checking that You Have Received Everything
10
Section 3.0 Installation
11
Overview
11
Two (2) (Reflect) or Four (4) (Double Reflect) Cross Mode
12
One (1) (Direct) Cross Mode
12
Site Selection
13
The Wall-Mount Enclosure
13
The Transducers
14
Transducer Mounting Recommendations
15
Mechanical Installation
16
Dimensions
16
Enclosure Dimensions
16
Series Transducer Dimensions
17
Series Transducer Dimensions
18
Series Mechanical Installation
19
Preparing the Pipe for 10 Series Transducers
19
Two (2) or Four (4) Cross Mounting Installation for 10 Series Transducers
20
Series Mechanical Installation
21
Preparing the Pipe for 20 Series Transducers
21
Two (2) or Four (4) Cross Mounting Installation for 20 Series Transducers
22
One (1) Cross Mounting Installation for 20 Series Transducer
25
Series Mechanical Installation
30
Preparing the Pipe for 30 Series Transducers
30
Two (2) Cross Mounting Installation for 30 Series Transducers
31
One (1) Cross Mounting Installation for 30 Series Transducers
33
Connecting the Transducer Signal Cables
37
Electrical Installation
38
Input Power Requirements
38
Power and Output Signal Wiring Details
39
Transducer and Sensor Wiring Details
40
Section 4.0 Start - up
41
Navigating the Run Mode & Programming
41
Run Mode & Programming
42
Run Mode Icons
43
Run Mode
44
Programming Menu
46
Section 5.0 Bacnet Ms/Tp
55
Bacnet Protocol Implementation Conformance Statement
56
Section 6.0: Modbus
61
Modbus Rtu Rs485
61
Modbus Tcp/Ip
61
IP Address Setting (Ipv4)
62
IP Address Setting (Ipv6)
64
Units and Functions
64
Modbus Memory Map
65
Report Slave ID Function Code
72
Section 7.0: Commissioning
73
Helpful Hints for Start - up and Commissioning
73
Commissioning Procedure
73
Commissioning Worksheet
74
Section 8.0: Troubleshooting
75
Appendix A - Speed of Sound in Pure Water Table ( Imperial Units )
76
Appendix B - Speed of Sound in Pure Water Table ( si Units )
77
Appendix C - Speed of Sound in Glycol Water Table
78
Appendix D - Pipe Charts
79
Advertisement
Onicon F-4300 Installation & Operation Manual (48 pages)
Clamp-on Ultrasonic Flow Meter
Brand:
Onicon
| Category:
Measuring Instruments
| Size: 2 MB
Table of Contents
Safety Information
2
Table of Contents
3
1 Introduction
5
Purpose of this Guide
5
Principle of Operation
5
Typical F-4300 Flow Meter
5
Standard Features and Specifications
6
Maintenance
7
Additional Hardware that May be Required
7
Working Environment
7
Warranty and Serial Number
7
2 Unpacking
8
Checking that You Have Received Everything
8
3 Installation
9
Overview
9
Site Selection
10
Mechanical Installation
12
Mounting the Enclosure
12
Preparing the Pipe
13
Or 2 Cross Reflect Mounting Using Frames and Spacer Bar
13
Cross Mode Direct Mounting Using Brackets and Spacer Bar
14
Installing Transducers in Bracket and Spacer Bar Hardware
16
Connecting the Transducer Signal Cables
18
Electrical Installation
19
Input Power Options
19
Electrical Connections
20
Connections for Meters Powered by 100-240 VAC
20
Connections for Meters Powered by 10-30 VAC/VDC
21
4 Start-Up
22
Navigating the Run Mode & Programming Pages
22
Run Mode & Programming Page Layout
23
Run Mode Icons
24
Run Mode Pages
24
Programming Menu
26
5 Bacnet Ms/Tp
32
Bacnet OBJECT TYPES
32
Protocol Implementation Statement
32
Device Object
33
Analog Input(S)
34
Analog Value(S)
35
Binary Value(S)
36
Multi State Value
37
6 Modbus
38
Modbus Memory Map
39
Report Slave ID Function Code
40
7 Commissioning for Onicon Clamp-On Ultrasonic Flow Meters
41
Helpful Hints for Start-Up and Commissioning
41
Commissioning Procedure
41
Commissioning Worksheet
42
8 Troubleshooting
43
Appendix
44
Sonic Velocity Relative to Temperature of Pure Water
44
Onicon F-4300 Installation Hardware Instruction (4 pages)
For Use with Kit: INSTL0501-TSC & INSTL0502-TSC
Brand:
Onicon
| Category:
Measuring Instruments
| Size: 1 MB
Advertisement
Advertisement
Related Products
Onicon F-4600 Series
Onicon F-4000 Series
Onicon F-4400
Onicon F-1101
Onicon F-1211
Onicon F-1220
Onicon FB-1230
Onicon Fox Thermal FT4X
Onicon FP-4400
Onicon FT-3500
Onicon Categories
Measuring Instruments
Monitor
Transmitter
Security Sensors
Accessories
More Onicon Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL