Sign In
Upload
Manuals
Brands
OHAUS Manuals
Scales
Explorer EX224AD
OHAUS Explorer EX224AD Manuals
Manuals and User Guides for OHAUS Explorer EX224AD. We have
2
OHAUS Explorer EX224AD manuals available for free PDF download: Instruction Manual, Service Manual
OHAUS Explorer EX224AD Instruction Manual (150 pages)
Brand:
OHAUS
| Category:
Scales
| Size: 11 MB
Table of Contents
Table of Contents
3
Introduction
7
Description
7
Features
7
Safety Precautions
7
Installation
8
Unpacking
8
Installing Components
9
Terminal Setup
9
Installing the Wind Ring, Weighing Platform on Models EX124, EX224, and EX324
9
Installing the Draft Shield Glass and Doors on Draft Shield Models
10
Installing the Weighing Pan & Wind Shield - Non-Draft Shield Models
11
Selecting the Location
11
Leveling the Equipment
11
Connecting Power
12
AC Adapter
12
Connecting the Interface
12
Adjusting the View Angle of the Terminal
12
Remote Terminal Operation
13
Separating the Terminal from the Weighing Base
13
Terminal Mounting
13
Initial Calibration
13
Operation
14
Overview of Display, Home Screen
14
Principal Functions and Main Menu
14
Overview of Parts and Features -Draft Shield Models
15
Overview of Parts and Features - Non-Draft Shield Models
16
Overview of Parts and Features - Terminal
17
Functions and Their Icons
18
Standby
18
Printing Data
18
Applications
18
Touchless Sensor Status
18
Autocal
18
Menu
18
More
18
Level Assist
18
Zero Operation
18
Weighing Units
19
Preset Tare
19
Calibration Test
19
Calculator
19
Stopwatch
19
Logout
19
Applications
20
Weighing
21
Edit Settings
21
Application Setup
22
Statistics for Weighing
23
Parts Counting
24
Standard Parts Counting (Default)
24
Application Setup
27
Parts Counting - Check
28
Parts Counting - Fill
29
Statistics for Parts Counting
30
Percent Weighing
32
Edit Settings
32
Application Setup
35
Check Weighing
36
Standard Check Weighing (Default)
36
Edit Settings
36
Application Setup
37
Check Weighing - Nominal/Weight Mode
38
Check Weighing - Nominal/Percent Tolerance Mode
39
Display Settings
40
Statistics for Check Weighing
41
Dynamic/Animal Weighing
42
Edit Settings
43
Application Setup
43
Dynamic Weighing - Semi-Auto
44
Dynamic Weighing - Automatic
45
Statistics for Dynamic Weighing
46
Filling
47
Edit Settings
47
Application Setup
48
Statistics for Filling
49
Totalization
51
Totalization - Manual (Default)
51
Application Setup
52
Totalization - Automatic
53
Formulation
54
Free Formulation (Default)
54
Application Setup
55
Recipe Formulation
56
Differential Weighing
59
Item Settings
59
Application Setup
61
Differential Weighing with Auto-Process on
62
Density Determination
63
Measuring the Density of a Solid Using Water (Default)
63
Application Setup
65
Measuring the Density of a Buoyant Material Using Water
66
Measuring the Density of a Solid Using an Auxiliary Liquid
66
Measuring the Density of a Liquid Using a Calibrated Sinker (Not Supplied)
67
Measuring the Density of Porous Material Using Oil
69
Peak Hold
71
Peak Hold - Semi-Automatic (Default)
71
Application Setup
72
Peak Hold - Manual
73
Peak Hold - Automatic
74
Ingredient Costing
75
Item Settings
75
Application Setup
78
Pipette Adjustment
79
Pipette Adjustment - Manual (Default)
79
Begin Pipette Adjustment Process
81
Application Setup
82
Statistical Quality Control (SQC)
83
Edit Settings
83
Begin the SQC Process
84
Application Setup
86
Statistics
87
Library
87
Creating a Library Record
87
Retrieving a Library Record
88
Deleting a Stored Library Record
88
Additional Features
89
Weigh below
89
Menu Settings
90
Menu Navigation
90
Changing Settings
90
Main Menu
91
Calibration
91
Calibration Sub-Menu
91
Internal Calibration (Autocal™)
91
Automatic Calibration
91
Autocal™ Adjustment
92
Span Calibration
92
User Calibration
93
Calibration Test
93
User Settings
94
User Settings Sub-Menu
94
Language
94
Volume
94
Display Settings
94
User Manager
94
Functions Configuration
95
Touchless Sensor Setup
95
Draft Shield Light
95
Balance Setup
96
Balance Set-Up Sub-Menu
96
Stable Range
96
Filter Level
96
Auto Zero Tracking
96
Auto Tare
97
Gross Indicator
97
Legal for Trade
97
Graduations
97
Date & Time
97
Applications
98
Turning an Application ON/OFF
98
Weighing Units
98
Units Sub-Menu
98
Turning a Unit ON/OFF
99
Custom Units
99
GLP and GMP Data
100
GLP Data Sub-Menu
100
Header
100
Balance Name
100
User Name
100
Project Name
100
Communication
101
Communication Sub-Menu
101
Baud Rate
101
Transmission
101
Handshake
102
Alternate Command
102
Print Output
102
Auto Print
103
Print Calibration Data
103
Print Content
103
Print Layout
105
Data Transfer Function
105
Double Click Accessibility Options in Control Panel
106
Library
107
I/O Settings
107
Diagnostics
107
Level Bubble Light
107
Draft Shield Light (Analytical Models)
107
Sensors
107
Service Menu
107
Factory Reset
108
Factory Reset Sub-Menu
108
Reset Calibration
108
Reset User Settings
108
Reset Balance Setup
108
Reset Application Modes
108
Reset Weighing Units
108
Reset GLP and GMP Data
108
Reset Communication
108
Reset I/O Settings
108
Lockout
109
Lockout Sub-Menu
109
Lock Calibration
109
Lock User Settings
109
Lock Balance Setup
109
Lock Application Modes
109
Lock Weighing Units
109
Lock GLP and GMP Data
109
Lock Communication
110
Lock Library
110
Lock I/O Settings
110
Factory Reset
110
Securing the Menu and Key Lock Menu Settings
110
Information
111
Using Information
111
Legal for Trade
112
Settings
112
Verification
112
Sealing
112
Printing
113
Connecting, Configuring and Testing the Printer/Computer Interface
113
Printout Examples
114
Output Format
122
Maintenance
123
Calibration
123
Cleaning
123
Troubleshooting
123
Service Information
123
Technical Data
124
Specifications
124
Drawings and Dimensions
131
Parts and Accessories
132
Icons List
133
Communication
139
Interface Commands
139
RS232 (DB9) Pin Connections
142
The USB Interface
142
Software Updates
146
Compliance
147
Advertisement
OHAUS Explorer EX224AD Service Manual (86 pages)
Balances
Brand:
OHAUS
| Category:
Scales
| Size: 5 MB
Table of Contents
Table of Contents
3
1 Getting Started
7
Service Facilities
7
Specifications
8
Tools and Test Equipment Required
8
Unit Capacity and Readability
12
Balance Operation
14
Main Menu and Principal Functions
15
Changing Settings
16
Legal for Trade (Lft)
18
Menu Structure
19
Securing the Menu and Key Lock Menu Settings
20
Display Touch Areas
20
Capacity and Readability
22
Diagnostic Guide
22
3 Maintenance / Repair Procedures
26
Preventive Maintenance
26
Opening the Balance
26
Opening the Terminal Module
28
Opening the Base Module with a Draftshield
30
Opening the Base Module (Top Loader)
32
Opening the Base Module (EX12001, EX24001, EX35001)
34
2 Remove the 2 Screws that Hold the Spider to the Top Housing and Lift off the Spider. 28
35
4 Remove the Top Housing
35
REPLACING the LOAD CELL (Not 12001, 24001 and 35001)
36
REPLACING the LOAD CELL (12001, 24001 and 35001)
41
Removing Load Cell Protection Screws
42
Replacing the Printed Circuit Board Assemblies (Pcba)
43
Base
45
Replacing the Function Label
48
Replacing the Touch Panel
49
Replacing the Feet
49
Testing
51
Test Masses Required
51
Operational Test
52
Performance Tests
52
Repeatability Test (Non-Approved Models)
53
Repeatability Worksheet
54
Linearity Test
55
Off Center Load Mass Values
56
Terminal Spare Parts
59
Base Spare Parts (Non-Draftshield Models)
61
Base Spare Parts (Draftshield Models)
63
Base Spare Parts (Ex12001, Ex24001, Ex35001)
65
Draftshield Spare Parts
67
Appendix A - User Calibrations
69
A.2 Linearity Calibration
70
Appendix B - Diagnostic / Service Menu
71
B.2 Service Sub-Menu
72
Service Calibration Mass Values
75
C-1 Interface Command List
77
Advertisement
Related Products
OHAUS EX224
OHAUS Explorer EX224M
OHAUS Explorer EX224N
OHAUS Explorer EX2241
OHAUS EX223
OHAUS Explorer EX225D/AD
OHAUS Explorer EX225DM
OHAUS Explorer EX225DM/AD
OHAUS Explorer EX225M/AD
OHAUS Explorer EX2232
OHAUS Categories
Scales
Measuring Instruments
Laboratory Equipment
Recording Equipment
Touch Panel
More OHAUS Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL