Sign In
Upload
Manuals
Brands
Oceasoft Manuals
Data Loggers
Cobalt X2
Oceasoft Cobalt X2 Manuals
Manuals and User Guides for Oceasoft Cobalt X2. We have
2
Oceasoft Cobalt X2 manuals available for free PDF download: User Manual
Oceasoft Cobalt X2 User Manual (119 pages)
Brand:
Oceasoft
| Category:
Data Loggers
| Size: 3 MB
Table of Contents
Notices and Safety
2
Safety Instructions
2
Electrical Warning
2
Battery Warning
2
Certifications and Compliance
3
Table of Contents
7
Table of Figures
11
Introduction
14
About this User Guide
14
Terminology
14
Oceaview / Cobalt X Solution Overview
15
Lorawan Vs Bluetooth Wireless Topologies
15
Figure 1 - Data Loggers in Lorawan Mode Communicate with a Lorawan Receiver Connected to the Oceaview Web Platform
15
Figure 2 - Data Logger in Bluetooth Mode with Oceabridge Gateway
16
Cobalt X Data Logger Features
17
Information Flow
18
Figure 3 - Data Loggers Communicate with the Web Platform Either Via a Local Lorawan or
18
Lorawan Operation Overview
19
Bluetooth-Only Operation Overview
20
Hardware Overview
21
Front View
21
Figure 4 - Cobalt X2 Data Logger with Two External Sensors
21
Rear View
22
Side View
22
Figure 5 - Rear View of the Cobalt X Data Logger
22
Figure 6 - Side View of the Cobalt X Data Logger
22
Bottom View
23
Figure 7 - Bottom View of the Cobalt X2 Module (with Two Physical Connectors)
23
Compatible Sensor Types
24
Figure 8 - Cobalt X Data Logger with Wired Sensors and OCEASOFT Wireless Sensors
24
Package Contents
25
Technical Specifications
26
Characteristics
26
General
26
Wireless Technologies
26
Monitoring
27
Operating and Storage Conditions
27
Casing and Dimensions
27
Dimensions
28
Module (in MM)
28
Mounting Kit (in MM)
28
Power Options
28
Figure 9 - Cobalt X Module Dimensions
28
Figure 10 - Cobalt X Mounting Kit Details
28
Battery Specifications
29
AC Adapter (Optional - Provided Separately)
29
Getting Started
30
Prerequisites
30
Activating Your Cobalt X Data Logger
31
Figure 11 - Removing the Battery Cover
31
Figure 12 - Respect Battery Polarity Indications Inside Battery Cavity
32
Ready Screen / Regional Settings for Lorawan Frequency
33
Figure 13 - Select Region to Set the Correct Lorawan Frequency
33
Figure 14 - Cobalt X Ready Screen
34
Placing Your Cobalt X Data Logger
35
Optimizing Wireless Performance
35
General Recommendations
35
Lorawan
35
Bluetooth Low Energy (BLE, Bluetooth Smart)
35
Preparing the Mounting Kit
36
Using External Sensors
37
OCEASOFT Pt100 Smart-Sensors
37
Figure 15 - Cobalt X Wireless Data Logger with a Pt100 Smart-Sensor
37
Connecting Smart-Sensors
38
Figure 16 - Connecting an External Pt100 Sensor
38
Placing Smart-Sensors
39
Figure 17 - Sample Pt100 Access Port for ULT Freezer
40
Figure 18 - Pt100 (-200°C to +50°C) for Nitrogen/Cryogenic Tank
41
Digital Temperature Sensors
42
Figure 19 - Cobalt X Data Logger with External Digital Sensor
42
Connecting a Digital Sensor
43
Placing the Sensor
43
Figure 20 - Cobalt X Data Logger with External Digital Sensor
43
Figure 21 - Sensor Inside Refrigerator Chamber (Modules with External Sensor Only)
44
Figure 22 - Cobalt X Data Logger Mounted on the Refrigerator Door
44
Temperature/Humidity Smart-Sensors
45
Placing the Sensor
45
Triple CO - Temperature - Humidity Smart-Sensor
46
Overview
46
Figure 23 - Complete CO 2 -Temp-Humidity Sensor Assembly
46
Figure 24 - Sensor Locations on Unit
47
Key Specifications
48
Placing the Sensor and Cobalt X Data Logger
48
Figure 25 - Ribbon Cable Lays Flat Beneath Door Joint
48
Figure 26 - Sensor Unit Inside Incubator
49
Figure 27 - Slide the Smart-Sensor Clip Onto the Cobalt X Data Logger
49
Figure 28 - Power Connections for Triple Sensor Unit
50
Figure 29 - Join the Sensor Cables Together
50
Figure 30 - Place the Temperature/Humidity Sensor on the Back of the Unit
51
Figure 31 - Fully Connected Triple Sensor Assembly
51
Differential Pressure Smart-Sensor
53
Overview
53
Figure 32 - Single or Double Differential Pressure Sensor Models
53
Usage
54
Figure 33 - High Pressure Cleanroom Keeps Particles from Flowing in
54
Figure 34 - Low Pressure Cleanroom Keeps Particles from Flowing out
55
Figure 35 - High Pressure Cleanroom with an Airlock
56
Figure 36 - Low Pressure Cleanroom with an Airlock
56
Tube Placement
57
Figure 37 - Place Tube on High (+) Connector for Positive Values When Monitoring a High Pressure Cleanroom and Negative Values When Monitoring a Low Pressure Cleanroom
57
Figure 38 - Complete Differential Pressure Sensor Assembly
58
Key Specifications
59
Placement and Assembly
60
Figure 39 - Slide the Smart-Sensor Clip Onto the Cobalt X Data Logger
60
Remote Wireless Sensors
62
Activating an Emerald Module
62
Figure 40 - Place the Magnet on the Emerald Module to Activate Bluetooth
62
Activating an Atlas Module
64
Figure 41 - Press and Hold the Button on the Atlas Module to Activate Bluetooth
64
Cobalt X User Interface
65
Using the Touchscreen
65
Entering Your PIN Code
66
Figure 42 - PIN Code Keypad
66
Sensor Display and Control
67
Figure 43 - Cobalt X with Active Two Data Logging Sessions
67
Status Bar
68
Figure 44 - Cobalt X Status Bar
68
Data Logging
69
Figure 45 - One Active Data Logging Session
69
Figure 46 - Main Display Showing Simultaneous Data Logging Sessions
70
Figure 47 - Screen with more than Two Active Data Logging Sessions
71
Figure 48 - Display Showing One of the Sensors as a Remote (Wireless) Sensor
72
On-Demand Reading
73
Figure 49 - on Demand-Reading (Background Turns Blue Temporarily)
73
Screen Backlight
74
Screen Saver
74
Figure 50 - Cobalt X Display with Active Screen Saver
74
Configuration Menus
75
Figure 51 - Accessing Cobalt X Configuration Menus
75
Figure 52 - Menu Structure When Using Lorawan Wireless Operation
76
Figure 53 - Menu Structure When Using Bluetooth Wireless Operation
77
Settings
78
Figure 54 - Options in the Settings Menu
78
Setting Cobalt X Language
79
Figure 55 - Choosing Display Language
79
Changing the Temperature Unit
80
Figure 56 - Choosing Temperature Unit (C or F)
80
Decimal Places
81
Figure 57 - Values Displayed with One or Two Decimal Points
81
Figure 58 - Choosing One or Two Decimal Points to Display Values
81
Information
82
Figure 59 - Accessing Detailed Device Information
82
Sensors
83
Showing Sensors
83
Figure 60 - Sensor Information
83
Updating Sensors on Oceaview
84
Figure 61 - Confirmation that Sensors Are Updated on the Web Application
84
Using Remote Sensors
85
Figure 62 - Message Pending Bluetooth Sensor Discovery
85
Figure 63 - Tap to Pair the Wireless Sensor
86
Figure 64 - Wireless Sensor Indicated by Battery Counter and Wireless Icon
86
Figure 65 - Unpairing a Wireless Sensor
88
Figure 66 - Resetting a Wireless Sensor's Battery Counter
89
Figure 67 - Choose and Confirm the Wireless Sensor You Want to Replace (Current)
91
Figure 68 - Choose and Confirm the New Wireless Sensor
91
Figure 69 - Confirmation Message that the Swap Process Is Complete
92
Advanced Menu
93
Figure 70 - Features in the Advanced Menu
93
Calibrating the Cobalt X Screen
94
Figure 71 - Slide Your Finger or an Eraser Around the Screen for Best Touch Accuracy
94
Resetting the Cobalt X Data Logger Battery Counter
95
Figure 72 - Battery Counter Showing 100% Charge
95
Lorawan Network Setup
96
Figure 73 - Lorawan Network Options
96
Lorawan Wireless Range Test
97
Figure 74 - Lorawan Wireless Coverage Test
97
Lorawan Radio Performance
99
Figure 75 - Lorawan Radio Performance Test
99
Quick Server Connection Test
100
Figure 76 - Quick Server Connection Test
100
Figure 77 - Server Connection Test Results
100
Data Synchronization
101
Using Your Data Logger in Bluetooth-Only Mode
102
Figure 78 - Bluetooth Icon in Status Bar
102
Alarm Management
103
Figure 79 - Data Logger with Alarm Condition Indicated by Red LED
103
Figure 80 - Data Logger with Alarm Condition Indicated on Module Screen
104
LED Status Indications
105
Alarm Buzzer
106
Snoozing an Alarm
106
Figure 81 - Bell Icon Indicating that Alarm Sound Is Active
106
Figure 82 - Bell Icon Indicating that Alarm Sound Is Active
107
Acknowledging an Alarm
108
Figure 83 - Tap on Acknowledge Button to Clear Alarm
108
Figure 84 - Choose a Reason for Acknowledging the Alarm
109
Alarm Delay Indicator
110
Figure 85 - Pre-Alarm Indicator on Data Logger Display
110
Maintaining Your Modules
111
Replacing Batteries
111
Cleaning Instructions
113
Appendix 1 - Cobalt X Battery Life
114
Estimated Battery Life
114
Appendix 2 - Troubleshooting
115
Appendix 3 - EU Declaration of Conformity
118
Advertisement
Oceasoft Cobalt X2 User Manual (85 pages)
Brand:
Oceasoft
| Category:
Data Loggers
| Size: 4 MB
Table of Contents
Table of Contents
6
1 Introduction
9
Terminology Used in this Document
9
Cobalt X Solution
10
Module Features
10
Process Flow Summary
11
Product Overview
13
Front View
13
Rear View
14
Side View
14
Bottom View
15
Compatible Sensor Types
16
Package Contents
20
2 Technical Specifications
21
Characteristics
21
Dimensions
23
Module (in MM)
23
Mounting Kit (in MM)
23
Power Options
24
3 Getting Started
25
Prerequisites
25
Activating the Cobalt X Module
25
Splash Screen
26
4 Installing the Cobalt X Module
27
Requirements for Best Wireless Performance
27
Preparing the Mounting Kit
28
5 Using External Sensors
29
PT100 Smart Sensors
29
Connecting OCEASOFT Smart Sensors
30
Placing Smart Sensors
31
Digital Temperature Sensors
34
Connecting a Digital Sensor
35
Placing the Sensor
35
Temperature/Humidity Smart Sensors
37
Placing the Sensor
37
Remote Wireless Sensors
38
Placing the Sensor
38
6 Cobalt X Graphical User Interface
39
Before You Begin
39
Measurement Display & Control Elements
40
Status Bar
41
Datalogging
42
On-Demand Reading
43
Screen Backlight
44
Screen Saver
44
7 Configuration Menus
45
Settings
46
Setting Cobalt X Language
46
Modifying Cobalt X Theme
47
Changing the Temperature Unit
48
Information
49
Sensors
50
Showing Sensors
50
Updating Sensors on Oceaview
51
Remote Sensors
52
Installation (Advanced Menu)
61
Calibrating the Cobalt X Screen
62
Resetting the Battery Counter
63
Network Configuration
65
Checking Wireless Coverage
67
Checking Communication with the Lorawan Network
69
Data Synchronization
71
8 Alarm Management
72
Using the LED to Check Module Status
73
Alarm Buzzer
74
Snoozing an Alarm
74
Acknowledging an Alarm
76
Alarm Delay Indicator
78
9 Maintaining Your Modules
79
Replacing Batteries
79
Cleaning Instructions
80
10 Appendix 1 - Cobalt X Battery Life
81
10.1 Estimated Operating Lifetime
81
11 Appendix 2 - Troubleshooting
82
12 Appendix 3 - EU Declaration of Conformity
84
Advertisement
Related Products
Oceasoft Cobalt X1
Oceasoft Cobalt X Series
Oceasoft Cobalt L3
Oceasoft Atlas
Oceasoft Emerald
Oceasoft Phoenix
Oceasoft Categories
Data Loggers
Wireless Router
Receiver
Medical Equipment
More Oceasoft Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL