Sign In
Upload
Manuals
Brands
Monoxivent Manuals
Security Sensors
MACURCO CX-6
Monoxivent MACURCO CX-6 Manuals
Manuals and User Guides for Monoxivent MACURCO CX-6. We have
1
Monoxivent MACURCO CX-6 manual available for free PDF download: User Instructions
Monoxivent MACURCO CX-6 User Instructions (192 pages)
Carbon Monoxide & Nitrogen Dioxide Combination Detector, Controller and Transducer
Brand:
Monoxivent
| Category:
Security Sensors
| Size: 4 MB
Table of Contents
Table of Contents
3
Span Calibration for no 2 Sensor
3
General Safety Information
5
General Description
5
List of Warnings
5
Use Instructions and Limitations
6
Use for
6
Do NOT Use for
7
Features
7
Specifications
7
6-Series Low Voltage
8
12-Series Line Voltage
8
Installation and Operating Instructions
8
Location
8
Installation
9
6-Series Low Voltage
9
12-Series Line Voltage
15
Terminal Connection
21
6-Series Low Voltage
21
12-Series Line Voltage
22
Operations
23
Power up
23
Display Turned "On
23
Display Turned "Off
24
4-20Ma Loop
24
Configuration "CON
25
Default - Factory Settings
25
Select Default Configuration - "Def
26
Select Power-Up Test Setting - "Put
26
Select Display Configuration - "Dsp
26
Select Buzzer Configuration - "Buz
27
Select Alarm Relay Setting for CO - "Ars.C
27
Select Alarm Relay Setting for NO2 - "Ars.n
28
Select Alarm Relay Configuration - "Arc
28
Select Fan Relay Setting for CO - "Frs.C
28
Select Fan Relay Setting for NO2 - "Frs.n
29
Select Fan Relay Delay Setting - "Frd
29
Select Fan Relay Minimum Runtime Setting - "Frr
29
Select Fan Relay Latching Setting - "Frl
30
Select Trouble Fan Setting - "Tfs
30
Select 4-20Ma Output Setting - "420
31
Select 4-20Ma Mode - "420.N
31
Select Calibration Period for CO Sensor - "CAL.C
32
Select Calibration Period for no Sensor - "Cal.n
32
Troubleshooting
33
On-Board Diagnostics
33
4-20Ma Troubleshooting
33
Trouble Codes
33
Sensor Poisons
34
Sensor Expired
35
Maintenance
36
Sensor Life Reset
36
Cleaning
37
Testing
37
Operation Test
37
Manual Operation Test
38
Calibration and Test Kits
39
Gas Testing
40
Testing the Fan Relay
40
Testing the Alarm Relay
41
Testing the 4-20Ma Loop
41
Field Calibration Procedure
42
Aerosol Carbon Monoxide Test (Carbon Monoxide Only)
42
Zero Calibration for CO Sensor
42
Zero Calibration for no Sensor
43
Span Calibration for CO Sensor
43
Appendix A - Table of Figures
45
Appendix B - Menu Structure
46
Main Menu
46
Auto Test Menu "Buz
47
Configuration Menu "CON
48
Select Test Menu "Tst
55
CAL Menu
56
Sen Menu
58
Macurco Gas Detection Product Limited Warranty
60
Technical Support Contact Information
60
General Contact Information
60
Advertisement
Advertisement
Related Products
Monoxivent MACURCO CX-12
Monoxivent Macurco TX-12-ND
Monoxivent Categories
Security Sensors
Ventilation Hood
Transducer
Tools
More Monoxivent Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL