Sign In
Upload
Manuals
Brands
Mitsubishi Electric Manuals
Inverter
FR-D810W-0.75K-042
Mitsubishi Electric FR-D810W-0.75K-042 Manuals
Manuals and User Guides for Mitsubishi Electric FR-D810W-0.75K-042. We have
5
Mitsubishi Electric FR-D810W-0.75K-042 manuals available for free PDF download: Instruction Manual, Instructions, Manual, Maintenance
Mitsubishi Electric FR-D810W-0.75K-042 Instruction Manual (368 pages)
Function, Standard model
Brand:
Mitsubishi Electric
| Category:
Inverter
| Size: 5 MB
Table of Contents
Table of Contents
2
Chapter 1 Introduction
9
Product Checking
10
Inverter Model
10
Rating Plate
10
How to Read the SERIAL Number
11
Operation Steps
12
Related Manuals
14
Chapter 2 Basic Operation
15
Operation Panel
15
Components of the Operation Panel
15
Basic Operation of the Operation Panel
17
Parameter Setting Mode
18
Digital Characters and Their Corresponding Printed Equivalents
18
Changing the Parameter Setting Value
18
Parameter Setting Screen
19
Monitoring the Inverter
20
Monitoring of Output Current and Output Voltage
20
First Priority Monitor Screen
20
Displaying the Set Frequency
21
Easy Setting of the Inverter Operation Mode
22
Frequently-Used Parameters (Simple Mode Parameters)
23
Simple Mode Parameter List
23
Basic Operation Procedure (PU Operation)
25
Setting the Frequency on the Operation Panel (Example: Operating at 30 Hz)
25
Setting the Frequency with Switches (Multi-Speed Setting)
27
Setting the Frequency Using an Analog Signal (Voltage Input)
28
Setting the Frequency Using an Analog Signal (Current Input)
30
Basic Operation Procedure (External Operation)
32
Setting the Frequency on the Operation Panel
32
Setting the Frequency and Giving a Start Command with Switches (Multi-Speed Setting)
34
Setting the Frequency Using an Analog Signal (Voltage Input)
36
Changing the Frequency (Initial Value: 60 Hz) at the Maximum Voltage Input (Initial Value: 5 V)
38
Setting the Frequency Using an Analog Signal (Current Input)
39
Changing the Frequency (Initial Value: 60 Hz) at the Maximum Current Input (Initial Value: 20 Ma)
41
Basic Operation Procedure (JOG Operation)
42
Giving a Start Command by Using External Signals for JOG Operation
42
Giving a Start Command from the Operation Panel for JOG Operation
44
I/O Terminal Function Assignment
45
Chapter 3 Parameters
47
Parameter Initial Value Groups
47
Parameter List (by Parameter Number)
48
Use of a Function Group Number for the Identification of Parameters
62
Parameter List (by Function Group Number)
63
H: Protective Function Parameter
64
C: Motor Constant Parameters
66
A: Application Parameters
67
(G) Control Parameters
68
Chapter 4 Control Method
69
PM Sensorless Vector Control
70
Changing the Control Method and Mode
71
Selecting the Advanced Magnetic Flux Vector Control
74
Selecting the PM Sensorless Vector Control
76
Chapter 5 Speed Control under PM Sensorless Vector Control
83
Control Block Diagram
83
Setting Procedure of PM Sensorless Vector Control (Speed Control)
84
Setting the Torque Limit Level
86
Performing High-Accuracy, Fast-Response Control (Gain Adjustment)
89
Adjustment When the Motor Wiring Length Is Long
92
Troubleshooting in the Speed Control
93
Chapter 6 (E) Environment Setting Parameters
94
Clock
95
Real Time Clock Function
95
Reset Selection/Disconnected PU Detection/Pu Stop Selection
96
PU Display Language Selection
99
Buzzer Control
100
PU Contrast Adjustment
101
Display-Off Setting
102
Automatic Frequency Setting / Key Lock Operation Selection
103
Frequency Change Increment Amount Setting
105
RUN Key Rotation Direction Selection
106
Multiple Rating Setting
107
Parameter Write Selection
108
Password
110
Free Parameter
113
Setting Multiple Parameters by Batch
114
Extended Parameter Display and User Group Function
116
Operating Procedure
117
PWM Carrier Frequency and Soft-PWM Control
119
Inverter Parts Life Display
121
Maintenance Timer Alarm
125
Current Average Value Monitor Signal
126
Operation Example
126
Chapter 7 (F) Settings for Acceleration/Deceleration
129
Setting the Acceleration and Deceleration Time
129
Control Block Diagram
130
Acceleration/Deceleration Pattern
132
Remote Setting Function
134
Starting Frequency and Start-Time Hold Function
138
Minimum Motor Speed Frequency at the Motor Start up
140
Operation Mode Selection
141
Startup of the Inverter in Network Operation Mode at Power-ON
151
Start Command Source and Frequency Command Source During Communication Operation
152
Reverse Rotation Prevention Selection
158
Frequency Setting Using Pulse Train Input
159
JOG Operation
161
Operation by Multi-Speed Setting
163
Chapter 9 (H) Protective Function Parameters
165
Motor Overheat Protection (Electronic Thermal O/L Relay)
166
Cooling Fan Operation Selection
174
Earth (Ground) Fault Detection at Start
175
Inverter Output Fault Detection Enable/Disable Selection
176
Initiating a Protective Function
177
I/O Phase Loss Protection Selection
178
Retry Function
179
Emergency Drive
182
Connection Diagram
183
Checking Faulty Area in the Internal Storage Device
190
Limiting the Output Frequency (Maximum/Minimum Frequency)
191
Avoiding Machine Resonance Points (Frequency Jump)
193
Stall Prevention Operation
195
Load Characteristics Fault Detection
200
Setting Example
203
Motor Overspeeding Detection
205
Chapter 10 (M) Item and Output Signal for Monitoring
206
Speed Indication and Its Setting Change to Rotations Per Minute
206
Monitor Item Selection on Operation Panel or Via Communication
208
Monitor Display Selection for Terminal am
216
Adjustment of Terminal am
218
Energy Saving Monitoring
219
Output Terminal Function Selection
226
Output Signal List
227
Output Frequency Detection
232
Output Current Detection Function
235
Remote Output Function
237
Pulse Train Output of Output Power
239
Detection of Control Circuit Temperature
240
Chapter 11 (T) Multi-Function Input Terminal Parameters
241
Analog Input Selection
241
Response Level of Analog Input and Noise Elimination
245
Frequency Setting Voltage (Current) Bias and Gain
246
Operating Procedure
247
Input Terminal Function Selection
250
Input Signal List
251
Inverter Output Shutoff
253
Selecting the Condition to Activate the Second Function Selection (RT) Signal
255
Start Signal Operation Selection
256
Chapter 12 (C) Motor Constant Parameters
259
Applied Motor
259
Offline Auto Tuning
264
Offline Auto Tuning for a PM Motor
272
Chapter 13 (A) Application Parameters
279
Traverse Function
279
PID Control
281
Input/Output Signals
287
Adjustment Procedure
291
Calibration Example
292
Calibration of PID Display
295
Dancer Control
298
Automatic Restart after Instantaneous Power Failure / Flying Start with an Induction Motor
306
Automatic Restart after Instantaneous Power Failure / Flying Start with a PM Motor
311
Offline Auto Tuning for a Frequency Search
313
Power Failure Time Deceleration-To-Stop Function
317
Trace Function
319
Operation Outline
320
Chapter 14 (G) Control Parameters
326
Manual Torque Boost
326
Base Frequency Voltage
328
Load Pattern Selection
330
Energy Saving Control
332
SF-PR Slip Amount Adjustment Mode
333
DC Injection Brake
334
Stop Selection
336
Regenerative Brake Selection
338
Regeneration Avoidance Function
342
Increased Magnetic Excitation Deceleration
345
Slip Compensation
347
Speed Smoothing Control
348
Setting Method
348
Chapter 15 Checking and Clearing of Settings
349
Parameter Clear / All Parameter Clear
349
Operating Procedure
349
List of Parameters Changed from the Initial Values
350
Fault History Clear
351
Changing the Parameter Initial Value Group
352
Chapter 16 Appendix
353
For Customers Replacing the Conventional Model with this Inverter
353
Replacement of the FR-D700 Series
353
Specification Comparison between PM Sensorless Vector Control and Induction Motor Control
355
Parameters (Functions) and Instruction Codes under Different Control Methods
356
Warranty
366
Revisions
367
Advertisement
Mitsubishi Electric FR-D810W-0.75K-042 Instruction Manual (134 pages)
Connection Standard model, Ethernet model
Brand:
Mitsubishi Electric
| Category:
Inverter
| Size: 5 MB
Table of Contents
Table of Contents
2
Safety Instructions
5
Electric Shock Prevention
5
Fire Prevention
6
Injury Prevention
6
Additional Instructions
7
General Instruction
10
Chapter 1 Introduction
12
Harmonic Suppression Guidelines
12
Product Checking
13
Inverter Model
13
Rating Plate
13
How to Read the SERIAL Number
14
Component Names
15
Operation Steps
17
Related Manuals
18
Chapter 2 Installation and Wiring
19
Peripheral Devices
19
Inverter and Peripheral Devices
19
Peripheral Devices
22
2.2 Opening/Closing of the Front Cover and Removal/Reinstallation of the Comb-Shaped Wiring Cover
24
Installation of the Inverter and Enclosure Design
32
Inverter Installation Environment
32
High Altitude
33
Amount of Heat Generated by the Inverter
34
Output Current Reduction When the Surrounding Air Temperature Is between 50°C and 60°C for ND Rating and between 40°C and 60°C for SLD Rating
36
Standby Power Consumption by the Inverter
38
Cooling System Types for Inverter Enclosure
39
Inverter Installation
40
Inverter Placement
40
Terminal Connection Diagrams
42
Main Circuit Terminals
50
Details on the Main Circuit Terminals
50
Main Circuit Terminal Layout and Wiring to Power Supply and Motor
50
Applicable Cables and Wiring Length
52
Earthing (Grounding) Precautions
57
Control Circuit
58
Details on the Control Circuit Terminals (Standard Model)
58
Input Signal
58
Output Signal
59
Common Terminal
60
Details on the Control Circuit Terminals (Ethernet Model)
62
Specification
63
Control Logic (Sink/Source) Change
65
Wiring of Control Circuit
67
Control Circuit Terminal Layout
67
Wiring Method
68
Power Supply Connection
68
Wire Removal
69
Open/Close Button
69
Signal Inputs by Contactless Switches
70
Safety Stop Function
71
Connection Diagram
71
Communication Connectors and Terminals
73
PU Connector (Standard Model)
73
Communication Operation
73
Connection Cable
75
Wiring and Configuration of RS-485 Terminals
77
Terminal Layout
77
Ethernet Connector (Ethernet Model)
80
Wiring Precautions
81
Network Configuration
81
USB Connector
82
USB Device Communication
82
2.8 Connection of Stand-Alone Option Units
83
Connection of the Brake Resistor (FR-D820-0.4K-025 or Higher, FR-D840-0.4K-012 or Higher, FR-D820S-0.4K-025 or Higher, and FR-D810W-0.4K-025 or Higher)
83
Connection of the Brake Unit (FR-BU2)
86
Connection of the High Power Factor Converter (FR-HC2)
87
Manual (Function).)
87
Connection of the Multifunction Regeneration Converter (FR-XC)
88
Connection of the AC Reactor (FR-HAL)
89
Connection of the DC Reactor (FR-HEL)
90
Chapter 3 Precautions for Use of the Inverter
91
Electro-Magnetic Interference (EMI) and Leakage Currents
91
Leakage Currents and Countermeasures
91
Selecting the Rated Sensitivity Current for the Earth Leakage Circuit Breaker
92
Techniques and Measures for Electromagnetic Compatibility (EMC)
93
Power Supply Harmonics
96
Harmonic Suppression Guidelines in Japan
96
Conversion Factor
97
Installation of a Reactor
100
Power Shutdown and Magnetic Contactor (MC)
101
Countermeasures against Deterioration of the 400 V Class Motor Insulation
103
Checklist before Starting Operation
104
Failsafe System Which Uses the Inverter
107
Chapter 4 Specifications
110
Inverter Rating
110
Motor Rating
114
PM Motor EM-A
114
Motor Torque
117
Common Specifications
118
Outline Dimension Drawings
120
Inverter Outline Dimension Drawings
120
Dedicated Motor Outline Dimension Drawings
123
Chapter 5 Appendix
129
Instructions for EAC
129
Compliance with the UK Certification Scheme
129
Restricted Use of Hazardous Substances in Electronic and Electrical Products
130
Referenced Standard (Requirement of Chinese Standardized Law)
130
Warranty
132
Revisions
133
Mitsubishi Electric FR-D810W-0.75K-042 Instruction Manual (122 pages)
INVERTER Connection, Standard model
Brand:
Mitsubishi Electric
| Category:
Inverter
| Size: 4 MB
Table of Contents
Table of Contents
2
Safety Instructions
5
Electric Shock Prevention
5
Fire Prevention
6
Injury Prevention
6
Additional Instructions
7
General Instruction
10
Chapter 1 Introduction
12
Harmonic Suppression Guidelines
12
Product Checking
13
Inverter Model
13
Rating Plate
13
How to Read the SERIAL Number
14
Component Names
15
Operation Steps
16
Related Manuals
17
Chapter 2 Installation and Wiring
18
Peripheral Devices
18
Inverter and Peripheral Devices
18
Peripheral Devices
20
Opening/Closing of the Front Cover and Removal/Reinstallation of the Combed-Shaped Wiring Cover
23
Installation of the Inverter and Enclosure Design
31
Inverter Installation Environment
31
High Altitude
32
Amount of Heat Generated by the Inverter
33
Output Current Reduction When the Surrounding Air Temperature Is between 50°C and 60°C for ND Rating and between 40°C and 60°C for SLD Rating
35
Standby Power Consumption by the Inverter
37
Cooling System Types for Inverter Enclosure
38
Inverter Installation
39
Inverter Placement
39
Terminal Connection Diagrams
41
Main Circuit Terminals
45
Details on the Main Circuit Terminals
45
Main Circuit Terminal Layout and Wiring to Power Supply and Motor
45
Applicable Cables and Wiring Length
47
Earthing (Grounding) Precautions
52
Control Circuit
53
Details on the Control Circuit Terminals
53
Input Signal
53
Specification
53
Output Signal
54
Common Terminal
55
Control Logic (Sink/Source) Change
56
Wiring of Control Circuit
58
Control Circuit Terminal Layout
58
Wiring Method
59
Power Supply Connection
59
Wire Removal
60
Open/Close Button
60
Signal Inputs by Contactless Switches
61
Wiring Precautions
61
Safety Stop Function
62
Connection Diagram
62
Communication Connectors and Terminals
64
PU Connector
64
Communication Operation
64
Connection Cable
66
Wiring and Configuration of RS-485 Terminals
68
Terminal Layout
68
USB Connector
71
USB Device Communication
71
Connection of Stand-Alone Option Units
72
Connection of the Brake Resistor (FR-D820-0.4K-025 or Higher, FR-D840-0.4K-012 or Higher, FR-D820S-0.4K-025 or Higher, and FR-D810W-0.4K-025 or Higher)
72
Connection of the Brake Unit (FR-BU2(-H))
75
Connection of the High Power Factor Converter (FR-HC2)
76
Connection of the Multifunction Regeneration Converter (FR-XC)
77
Connection of the AC Reactor (FR-HAL)
78
Connection of the DC Reactor (FR-HEL)
79
Chapter 3 Precautions for Use of the Inverter
80
Electro-Magnetic Interference (EMI) and Leakage Currents
80
Leakage Currents and Countermeasures
80
Selecting the Rated Sensitivity Current for the Earth Leakage Circuit Breaker
81
Techniques and Measures for Electromagnetic Compatibility (EMC)
82
Power Supply Harmonics
85
Harmonic Suppression Guidelines in Japan
85
Conversion Factor
86
Installation of a Reactor
89
Power Shutdown and Magnetic Contactor (MC)
90
Countermeasures against Deterioration of the 400 V Class Motor Insulation
92
Checklist before Starting Operation
93
Failsafe System Which Uses the Inverter
96
Chapter 4 Specifications
99
Inverter Rating
99
Motor Rating
103
PM Motor EM-A
103
Motor Torque
106
Common Specifications
107
Outline Dimension Drawings
109
Inverter Outline Dimension Drawings
109
Dedicated Motor Outline Dimension Drawings
112
Chapter 5 Appendix
118
Instructions for EAC
118
Compliance with the UK Certification Scheme
118
Restricted Use of Hazardous Substances in Electronic and Electrical Products
119
Referenced Standard (Requirement of Chinese Standardized Law)
119
Warranty
120
Revisions
121
Advertisement
Mitsubishi Electric FR-D810W-0.75K-042 Instruction Manual (52 pages)
Standard model
Brand:
Mitsubishi Electric
| Category:
Inverter
| Size: 3 MB
Table of Contents
Table of Contents
2
Chapter 1 Introduction
4
Descriptions in this Instruction Manual
4
Maintenance
4
Related Manuals
4
What Is an Inverter
5
Advantages of Using Inverters
5
Operation Steps
6
How to Read the Model Name
7
Inverter Model
7
Rating Plate
7
How to Read the SERIAL Number
8
Component Names
9
Terms
11
Chapter 2 Installation and Main Circuit Wiring
12
Major Peripheral Devices
12
Three-Phase Power
12
Single-Phase Power
12
Selecting Required Devices and Cables
13
Earthing (Grounding)
16
Installing the Inverter
18
Opening/Closing of the Front Cover and Removal/Reinstallation of the Comb-Shaped Wiring Cover
19
Checking the Main Circuit Terminal Layout
23
Earthing (Grounding) the Inverter
25
Connecting the Inverter and the Motor
27
Connecting the Inverter and the Power Supply
28
Chapter 3 Driving a Motor
29
Checklist before Starting Operation
29
Basics of Start Commands
29
Basics of Frequency Commands
29
Preparation before Using each Operation Mode
31
Components of the Operation Panel
31
Digital Characters and Their Corresponding Printed Equivalents
31
Wiring to External Terminals
32
Open/Close Button
32
Setting the Operation Mode
32
Test Operation of each Operation Mode
33
External Operation Mode
33
PU Operation Mode
34
Operating Procedure
34
External/Pu Combined Operation Mode 1
35
External/Pu Combined Operation Mode 2
36
Chapter 4 Parameters
37
Setting and Changing Parameters
37
Operation
37
Explanation of Frequently-Used Parameters
38
Setting the Starting Torque Manually (Manual Torque Boost)
38
Limiting the Output Frequency (Maximum Frequency)
39
Setting the V/F Pattern (Base Frequency, Base Frequency Voltage)
39
Controlling the Frequency with Combinations of Terminals (Multi-Speed Operation)
40
Setting the Motor Acceleration/Deceleration Time (Acceleration/Deceleration Time)
40
Protecting the Motor from Overheating (Electronic Thermal O/L Relay)
42
Selecting the Operation Mode (Operation Mode Selection)
43
Chapter 5 Troubleshooting During Test Operation
45
Troubleshooting
45
Motor Does Not Start
45
Motor or Machine Is Making Abnormal Acoustic Noise
45
Motor Generates Heat Abnormally
45
Motor Rotates in the Opposite Direction
46
Speed Greatly Differs from the Setting
46
Acceleration/Deceleration Is Not Smooth
46
Operation Mode Is Not Changed Properly
46
Operation Panel Display Is Not Operating
46
The Motor Current Is too Large
47
Speed Does Not Accelerate
47
Unable to Write Parameter Setting
47
Fault Displays
48
Revisions
51
Mitsubishi Electric FR-D810W-0.75K-042 Instructions, Manual, Maintenance (54 pages)
INVERTER (Standard model / Ethernet model)
Brand:
Mitsubishi Electric
| Category:
Inverter
| Size: 1 MB
Table of Contents
Table of Contents
2
Chapter 1 Introduction
4
Digital Characters and Their Corresponding Printed Equivalents
5
Product Checking
6
Inverter Model
6
Rating Plate
6
How to Read the SERIAL Number
7
Related Manuals
8
Chapter 2 Protective Functions
9
Inverter Fault and Alarm Indications
9
Reset Method for the Protective Functions
10
Check and Clear of the Fault History
11
Operating Procedure
12
List of Fault Displays
13
Error Message
13
Causes and Corrective Actions
16
Calibration Error
16
Fan Alarm
21
Heat Sink Overheat
24
Input Phase Loss
24
Check First When You Have a Trouble
32
Motor Does Not Start
32
Motor or Machine Is Making Abnormal Acoustic Noise
34
Inverter Generates Abnormal Noise
34
Operating Noise of the Inverter's Fan Changes
34
Motor Generates Heat Abnormally
35
Motor Rotates in the Opposite Direction
35
Speed Greatly Differs from the Setting
35
Acceleration/Deceleration Is Not Smooth
36
Speed Varies During Operation
36
Operation Mode Is Not Changed Properly
37
Operation Panel Display Is Not Operating
37
The Motor Current Is too Large
37
Speed Does Not Accelerate
38
Unable to Write Parameter Setting
38
Unable to Establish Ethernet Communication
39
Chapter 3 Precautions for Maintenance and Inspection
40
Inspection Item
40
Daily Inspection
40
Periodic Inspection
40
Daily and Periodic Inspection
40
Checking the Inverter and Converter Modules
42
Checking Method
42
Cleaning
43
Replacement of Parts
44
Inverter Parts Life Display
44
Removal of the Fan
45
Smoothing Capacitors
47
Relay Output Terminals
47
Measurement of Main Circuit Voltages, Currents, and Powers
48
Measurement of Powers
50
Measurement of Voltages and Use of PT
50
Measurement of Currents
50
Measurement of Inverter Input Power Factor
50
Measurement of Converter Output Voltage (between Terminals P and N)
50
Measurement of Inverter Output Frequency
51
Insulation Resistance Test Using Megger
51
Withstand Voltage Test
51
Warranty
52
Advertisement
Related Products
Mitsubishi Electric FR-D810W-0.1K-008
Mitsubishi Electric FR-D810W-0.1K-008-E
Mitsubishi Electric FR-D810W-0.75K-042-E
Mitsubishi Electric FR-D810W-0.2K-014
Mitsubishi Electric FR-D810W-0.4K-025
Mitsubishi Electric FR-D820-0.1K-008-E
Mitsubishi Electric FR-D820S-1.5K-070
Mitsubishi Electric FR-D820S-0.75K-042
Mitsubishi Electric FR-D820S-0.4K-025
Mitsubishi Electric FR-D820S-0.2K-014
Mitsubishi Electric Categories
Air Conditioner
Controller
Projector
Inverter
Heat Pump
More Mitsubishi Electric Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL