Sign In
Upload
Manuals
Brands
Minebea Intec Manuals
Touch Panel
X3 Process Indicator PR 5410
Minebea Intec X3 Process Indicator PR 5410 Manuals
Manuals and User Guides for Minebea Intec X3 Process Indicator PR 5410. We have
1
Minebea Intec X3 Process Indicator PR 5410 manual available for free PDF download: Instrument Manual
Minebea Intec X3 Process Indicator PR 5410 Instrument Manual (340 pages)
Brand:
Minebea Intec
| Category:
Touch Panel
| Size: 10 MB
Table of Contents
Table of Contents
3
1 Introduction
11
Read the Manual
11
This Is What Instructions Look Like
11
This Is What Lists Look Like
11
This Is What Menus and Soft Keys Look Like
11
This Is What Safety Instructions Look Like
11
Hotline
12
2 Safety Instructions
13
General Notes
13
Intended Use
13
Incoming Goods Inspection
13
Before Operational Startup
13
Installation
13
Opening the Device
14
Supply Voltage Connection
14
Protective Conductor Connection
15
RF Interference Suppression
15
Failure and Excessive Stress
15
Important Note
16
Repairs and Maintenance
16
General Information
16
Electrostatically Sensitive Parts
16
Replacing Fuses
16
3 Device Description
17
General Information
17
Overview of the Device
17
Communication Protocols
18
Housing
18
General Information
18
Dimensions
19
Control Panel Cut-Out
19
Display and Control Panel
19
General Information
19
Overview
20
Display
20
Operating Elements
23
Overview of Connections
30
Plug-In Cards
31
4 Device Installation
33
General Information
33
Mechanical Preparation
33
EMC-Compliant Installation
34
Connecting the Screens
34
Connecting the Equipotential Bonding Conductor
34
Hardware Construction
34
Main Board
34
Display Board
36
Network Port
36
Interface
36
Digital Inputs
41
Digital Outputs
43
Connecting Analog Load Cells and Platforms
47
General Information
47
Connecting a Load Cell with a 4-Wire Cable
47
Connecting a Load Cell with a 6-Wire Cable
49
Connecting between 2 And8 Load Cells (650 Ω) Using a 6-Wire Connection Cable
50
Connecting Load Cells of Type Series PR 6221
50
Testing the Measuring Circuit
51
External Supply to Load Cells
51
Connecting to Input/Output Interface PR 1626/60
52
Connecting an Analog Weighing Platform (CAP
54
Accessories
56
General Information
56
2× RS-232-Interface
59
1× RS-232 Interface and 1× RS-485 Interface
61
Analog Inputs and Outputs
74
BCD Output (Open Emitter)
78
BCD Output (Open Collector)
82
Switch Settings
86
Output Modes
86
Opto-Decoupled Inputs and Outputs
88
Status Leds on Fieldbus Card
95
Profibus-DP Interface
96
Interbus-S Interface
101
Devicenet Interface
106
CC-Link Interface
110
Profinet I/O Interface
112
Ethernet IP Interface
115
5 "Standard" Application
118
Functions
118
General Information
118
Display Functions
118
6 Easyfill" Application
119
Functions
119
General Information
119
Display Functions
119
Filling Mode
119
Application Menu [Start]
119
7 Commissioning
121
Power Failure/Data Backup/Restart
121
Power Failure
121
Data Backup
121
Overwrite Protection
121
Restart
123
Switching on the Device
123
Setting the Date and Time
124
Switching off the Device
125
Warm-Up Time
125
Configuring and Calibrating Using the Front-Panel Keys
125
Parameter Table (Setup)
125
Recalibrating the Internal Weighing Point Using the Front-Panel Keys
129
Changing the Dead Load of the Internal Weighing Point Using the Front-Panel Keys
132
Displaying the Calibration Data of the Internal WP Using the Front-Panel Keys
133
Reading out Calibration Data for WP Dead Load and Max Using the Front-Panel Keys
135
Search for Pendeo Load Cells and Set Dead Load Using the Front-Panel Keys
136
Creating a PIN Code Using the Front-Panel Keys
137
Deleting the PIN Code Using the Front-Panel Keys
139
Entering Fieldbus Parameters Using the Front-Panel Keys
139
Entering the Network Address Using the Front-Panel Keys
141
Displaying the Network Address Using the Front-Panel Keys
144
Displaying/Deleting Alibi Entries Using the Front-Panel Keys
144
Displaying/Deleting Alibi Entries
145
Deleting Alibi Entries
146
Finding and Connecting a Device with a Notebook/Pc
146
Finding and Connecting the Device Automatically in the Network
147
Searching the Device in the Network with "Indicatorbrowser
147
Resetting the Network Address
148
Operation Using VNC
149
Operation Via a Web Browser
150
System Setup
151
Serial Ports Parameter
151
Date & Time
151
Operating Parameter
151
Printing Parameter
152
Fieldbus Parameter
152
Network Parameter
152
Weighing Points
153
Limit Parameter
159
Digital I/O Parameters
159
Analog Output Parameter
159
Calibrating Internal Weighing Point
160
General Information
160
Displaying Calibration Data
160
Selecting the Calibration Mode
162
Setting Maximum Load
165
Determining the Scale Interval
165
Determining the Dead Load
166
Calibrating with Weight
167
Calibrating with MV/V
168
Calibrating with Load Cell Data (Smart Calibration)
170
Subsequent Dead Load Correction
171
Linearization
172
Calculating the Test Value
172
Saving the Calibration
173
Cancelling a Calibration
174
Parameter Input
175
Calibrating Xbpi-Scale
181
General Information
181
Parameters for Serial Interface
181
Parameters for the Xbpi-Weighing Function
182
Setting up an Xbpi Platform
183
Xbpi-Parameter Tables
186
Setting the Xbpi Dead Load
189
Xbpi Calibration with User Specified Weight
190
Xbpi Calibration with Automatic Weight Detection
192
Xbpi Calibration with Default Weight
192
Xbpi Calibration with Built-In Weight
193
Xbpi Linearization
194
Calibrating Digital Load Cells of Type "Pendeo
195
General Information
195
Selecting and Configuring RS-485 Interface
196
Selecting the Load Cell Type
197
Calibration Procedure
197
Searching Load Cells
198
Assigning Load Cells
199
Calibrating Load Cells
201
Assigning Load Cell Names
203
Service Function
203
Corner Correction
205
Terminating/Saving Calibration
206
Parameter Input
206
Subsequent Dead Load Correction
208
Displaying Weighing Point Serial Number
208
General Parameter Settings
208
Selecting and Configuring Serial Interfaces
209
Date and Time
217
Operating Parameters
218
Print Parameters
221
Fieldbus Parameters
222
Network Parameters
225
Configuring Limit Values
227
Configuring Digital Inputs
232
Configuring Digital Outputs
235
Configuring Analog Output
240
System Information
241
Displaying the Version
242
Displaying the Status
243
Showing Hardware Options
244
Displaying the Alibi Memory
245
Displaying Pendeo Data
246
8 Production
249
General Notes
249
Configuration Using the Front-Panel Keys
249
Configuring Production Mode Using the Front-Panel Keys
249
Configuring Interaction Mode Using the Front-Panel Keys
250
Configuring Digital Inputs and Outputs Using the Front-Panel Keys
250
Configuring Printout Using the Front-Panel Keys
252
Starting the Application
255
Configuration Via a Notebook/Pc
255
Configuring Production Mode
255
Configuring Digital Inputs and Outputs
259
Configuring Material
261
Configuring Printout
264
Filling
265
9 Extended Functions
267
Hardware Test
267
Display Test
267
Front-Panel Key Test
267
Serial Interfaces
267
Inputs and Outputs
268
Functions Via the WEB Site
273
General Information
273
Displaying Weighing Points in a Table
274
Configuration Printout
275
Log Files
275
Screenshots
277
Error Log
277
Alibi Memory
278
Configuration Data
281
Resetting the Device to the Factory Settings Using the Front-Panel Keys
281
Resetting the Device to the Factory Settings
282
Updating New Software with Flashit
283
Updating in Network with a DHCP Service
283
Updating Via a Point-To-Point Connection with DHCP Service
285
Updating with a Fixed IP Address
287
10 Modbus Protocol
291
General Description
291
SPM Data in PR 1612 Modbus Mode
291
11 SMA Protocol
293
General Information
293
12 Fieldbus Interface
294
Fieldbus Interface Configuration
294
Scale Protocol (8-Byte) for the "Standard" Application
294
Write Window (Input Area)
295
Read Window (Output Area)
296
Reading and Writing Data
296
Description of the I/O Area (Read/Write Window)
297
Special Hints for Devicenet and Ethernet-IP
302
Fieldbus Register
302
Filling Protocol (64-Byte) for the "Easyfill" Application
307
Write Window (Input Area)
307
Read Window (Output Area)
308
Indicator Functions
308
Filling Functions
308
Setup of the Fieldbus Interface
310
General Information
316
Addressing
317
Repairs and Maintenance
323
Cleaning
324
15 Disposal
325
16 Error Messages
326
Error Messages for Xbpi Scales
327
Error Messages During Calibration
328
General Error Messages
330
Error Numbers @ "LAST_ERROR
332
Error in the "Easyfill" Application
333
17 Specifications
334
Effect of Ambient Conditions
335
Weighing Electronics
336
Connecting Cables
337
18 Appendix
338
Test Connector
339
Advertisement
Advertisement
Related Products
Minebea Intec PR 5410
Minebea Intec PR 5410/00
Minebea Intec PR 5410/01
Minebea Intec PR 5410/03
Minebea Intec PR 5410/04
Minebea Intec PR 54/15
Minebea Intec PR 54/100
Minebea Intec PR 54/30
Minebea Intec PR 54/200
Minebea Intec PR 54/50
Minebea Intec Categories
Scales
Accessories
Cable Box
Industrial Equipment
Racks & Stands
More Minebea Intec Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL