Manuals and User Guides for Microm Fire-Link 3. We have
1
Microm Fire-Link 3 manual available for free PDF download: Installation And Operation Manual
Microm Fire-Link 3 Installation And Operation Manual (48 pages)
for Emergency and Fire Alarm System
Brand:
Microm
| Category:
Cables and connectors
| Size: 3 MB
Table of Contents
Table of Contents
3
Introduction
7
The Fire-Link 3 Wireless Emergency and Fire Alarm System
7
Features
7
General Notes
7
Fire-Link 3 Wireless Overview
8
Fire-Link 3 Wireless Components
8
Table 1 Fire-Link 3 Wireless Components
8
ZC-301W Zone Controller (ZC)
9
WR-3001R/W Wireless Input/Output Unit (WIO)
9
Input Module and Relay Module
9
System Overview
10
Figure 1 System Components
10
Zone Controller Installation
11
Installing the Zone Controller Enclosure
11
Installation Tips
12
Overall Dimensions of the Zone Controller
12
Figure 2 Zone Controller Enclosure Dimensions
12
Mechanical Installation of the Zone Controller
13
Conduits for Wiring
13
Figure 3 Mechanical Installation of the Zone Controller
13
Clearances
14
Figure 4 Zone Controller Mounting Holes Dimensions
14
Connect the Power
15
AC Power
15
Battery Power
15
Figure 5 Zone Controller AC and Battery Power Wiring
15
DIP Switches
16
Setting the DIP Switches
16
Figure 6 Location of Zone Controller DIP Switches and USB Port
16
Figure 7 DIP Switches on the Zone Controller Set to Channel ID 19 and PAN ID 1126
16
Wireless Input/Output Unit Installation
17
Installing the WIO Unit
17
Installation Tips
17
Parts
18
Dimensions
18
Figure 8 Parts of the Wireless Input/Output Unit
18
Figure 9 Wireless Input/Output Unit Mounting Plate Dimensions
18
DIP Switches
19
Setting the DIP Switches
19
Figure 10 Location of Wireless Input/Output Unit DIP Switches and Connections
19
Mounting the Wireless Input/Output Unit
20
Figure 11 DIP Switches on the Wireless Input/Output Unit Set to Channel ID 19 and PAN ID 1126
20
Figure 12 Mounting Plate (Front View)
20
Figure 13 Mounting Plate (Back View)
21
Figure 14 Mounting the Wireless Input/Output Unit on the Mounting Plate
22
Connecting the Notification Appliance to the Wireless Input/Output Unit
23
Figure 15 Generic Notification Appliance Mounting Plate with End of Line Resistor
23
Figure 16 Wiring the Notification Appliance Mounting Plate to WIO Unit
24
Figure 17 Notification Appliance Mounting Holes Available on the WIO Unit
24
Wiring
25
Zone Controller Board Terminal Connectors Location
25
Zone Controller Input Terminals
25
Figure 18 Zone Controller Board Terminal Connectors
25
Figure 19 Zone Controller Inputs 1-4
25
Zone Controller Addressable Loop Terminals
26
Zone Controller Output Terminals
26
Rs-485
26
Figure 20 Zone Controller Addressable Loop
26
Figure 21 Zone Controller Outputs
26
FACP NAC Wiring to Zone Controllers
27
Figure 22 Wiring from Conventional FACP to Zone Controllers Input Zone 1
27
Figure 23 Wiring from Conventional FACP to Zone Controllers Input Zones 2, 3 and 4
27
Zone Controller Relay Wiring to FACP Input Zones
28
FACP SLC Loop Wiring to Zone Controllers
28
Figure 24 Wiring from Zone Controllers to Conventional FACP
28
Figure 25 Wiring from any FACP to Fire-Link 3 Wireless System Via Class B SLC Loop
29
Mircom and Secutron FACP SLC Loop Wiring to Zone Controllers
30
Figure 26 MIX-M500RAP(A) Advanced Protocol Addressable Relay Control Module Wiring Detail
30
Figure 27 MIX-M500MAP(A) Advanced Protocol Addressable Monitor Module Wiring Detail
30
Figure 28 Addressable Loop SLC Wiring from a Mircom (Secutron) FACP
31
Figure 29 Class X (or Style 7) SLC Wiring from a Mircom (Secutron) FACP
32
Indicators and Controls
33
Zone Controller Leds and Controls (Ancillary for ULC)
33
Buttons
33
Figure 30 Zone Controller Leds and Controls
33
Leds
34
Buzzer
34
Figure 31 Trouble Condition and Location
34
Table 2 Description of Zone Controller Leds
34
Wireless Input/Output Unit Leds and Buttons
35
Buttons
35
Figure 32 Wireless Input/Output Leds and Buttons
35
Table 3 Description of Wireless Input/Output Unit Leds
35
Leds
36
Operation
37
Wireless Input/Output Unit Operation
37
Normal Operation
37
Button Operation (UL)
37
Button Operation (ULC)
37
Button Operation While in Trouble Condition
37
Alarm Condition
37
Alarm Tones
37
Button Operation While in Alarm Condition (UL)
38
Button Operation While in Alarm Condition (ULC Dwelling Unit Use Only)
38
Figure 33 Temporal and Alert Alarm Code
38
DIP Switch Settings for each ZC and WIO
40
Channel ID Settings
40
Table 4 Wireless Input/ Output Unit and Zone Controller Channel ID Setting
40
PAN ID Settings
41
Table 5 Wireless Input / Output Unit and Zone Controller PAN ID Setting
41
Appendix A - Specifications and Features
42
Table 6 Wireless Input/Output Unit Specifications
42
Table 7 Zone Controller Specifications
43
Warranty and Warning Information
44