Sign In
Upload
Manuals
Brands
MICRO-EPSILON Manuals
Accessories
ILD 1220-50
MICRO-EPSILON ILD 1220-50 Distance Sensor Manuals
Manuals and User Guides for MICRO-EPSILON ILD 1220-50 Distance Sensor. We have
3
MICRO-EPSILON ILD 1220-50 Distance Sensor manuals available for free PDF download: Operating Instructions Manual
MICRO-EPSILON ILD 1220-50 Operating Instructions Manual (96 pages)
Brand:
MICRO-EPSILON
| Category:
Industrial Electrical
| Size: 4 MB
Table of Contents
Table of Contents
3
Safety
9
Symbols Used
9
Warnings
9
Notes on CE Marking
10
Notes on UKCA Marking
11
Intended Use
11
Proper Environment
11
Laser Safety
12
Functional Principle, Technical Data
14
Short Description
14
Auto Target Compensation (ATC)
14
Technical Data
15
Delivery
17
Unpacking, Included in Delivery
17
Storage
17
Installation
18
Notes for Operation
18
Reflection Factor of the Target Surface
18
Error Influences
19
Light from Other Sources
19
Color Differences
19
Temperature Influences
19
Mechanical Vibration
19
Movement Blurs
19
Surface Roughness
20
Angle Influences
21
Optimizing the Measuring Accuracy
22
Mounting, Dimensions
23
Indicator Elements at Sensor
25
Electrical Connections
26
Connection Possibilities for Parametrization
26
Pin Assignment
28
Supply Voltage
29
Laser on
29
RS422 Connection with USB Converter IF2001/USB
30
Analog Output
30
Multifunctional Input
31
Digital Output
32
Sensor Cable
33
Operation
34
Getting Ready for Operation
34
Parameterizing Via Web Interface
35
Preconditions
35
Access Via Web Interface
36
Programming Via ASCII Commands
38
Timing, Measurement Value Flux
38
Set Sensor Parameter
39
Preliminary Remarks to the Adjustments
39
Overview Parameter
39
Inputs
40
Overview Functions
40
Zeroing
40
Zeroing with Select Key
41
Zeroing with Hardware Input
42
Signal Processing
43
Preliminary Remark
43
Measuring Rate
43
Error Handling
43
Triggering
44
General
44
Value Output Trigger
45
Outputs
46
Overview
46
Digital Output, RS422
47
Values, Ranges
47
Characteristics Digital Output
48
Analog Output Scaling
50
Output Scaling
50
Output Scaling with Key Select
51
Output Scaling Via Hardware Input
52
Calculation of Measuring Value Using Analog Current
53
Characteristics Distance Value and Analog Output
55
Zeroing and Teaching Analog Output
57
Error Output
58
Output Interface
59
System Settings
60
General
60
Unit, Language
60
Keylock
60
Load, Save
61
Import, Export
63
Access Authorization
64
Sensor Reset
65
Digital Interface RS422
66
Measurement Data Format
66
Conversion of the Binary Data Format
67
Cleaning
67
Software Support with Medaqlib
68
Disclaimer
69
Service, Repair
69
Decommissioning, Disposal
70
Appendix
71
A 1 Optional Accessories
71
A 2 Factory Settings
72
A 3 ASCII Communication with Sensor
73
A 3.1 General
73
A 3.2 Overview Commands
75
A 3.3 Commands
78
A 3.3.1 General Commands
78
A 3.3.1.1 Help
78
A 3.3.1.2 GETINFO, Sensor Information
79
A 3.3.1.3 LANGUAGE, Website
80
A 3.3.1.4 RESET, Boot Sensor
80
A 3.3.1.5 ECHO, Switching the Command Reply, ASCII Interface
80
A 3.3.1.6 PRINT, Sensor Settings
81
A 3.3.2 User Level
82
A 3.3.2.1 LOGIN, Change of the User Level
82
A 3.3.2.2 LOGOUT, Change into User Level
82
A 3.3.2.3 GETUSERLEVEL, User Level Request
82
A 3.3.2.4 STDUSER, Set Standard User
82
A 3.3.2.5 PASSWD, Change Password
82
A 3.3.3 Triggering
83
A 3.3.3.1 TRIGGER, Selection
83
A 3.3.3.2 MFILEVEL, Input Pulse Multifunctional Input
83
A 3.3.3.3 TRIGGERCOUNT, Number of Displayed Measurement Values
83
A 3.3.4 Interfaces
84
A 3.3.4.1 Baudrate, Rs422
84
A 3.3.4.2 UNIT, Web Interface
84
A 3.3.4.3 MFIFUNC, Function Selection Multifunctional Input
84
A 3.3.4.4 ERROROUT1, Activate Error Output
84
A 3.3.4.5 ERRORLEVELOUT1, Output Level Digital Output
85
A 3.3.4.6 Errorlimit
85
A 3.3.4.7 Errorhysteresis
85
A 3.3.4.8 Errorouthold
85
A 3.3.5 Handling of Setups
86
A 3.3.5.1 Import
86
A 3.3.5.2 Export
86
A 3.3.5.3 MEASSETTINGS, Load / Save Measurement Settings
87
A 3.3.5.4 BASICSETTINGS, Load / Save Device Settings
88
A 3.3.5.5 SETDEFAULT, Default Settings
88
A 3.3.6 ANALOGSCALE, Scaling the Analog Output
88
A 3.3.7 Key Function
89
A 3.3.7.1 KEYFUNC, Choose Key Function
89
A 3.3.7.2 KEYLOCK, Set Keylock
89
A 3.3.8 Measurement
90
A 3.3.8.1 MEASRATE, Measuring Rate
90
A 3.3.8.2 LASERPOW, Laser Power
90
A 3.3.8.3 MASTERMV, Mastering / Zeroing
90
A 3.3.9 Data Output
91
A 3.3.9.1 OUTPUT, Selection of Measurement Value Output
91
A 3.3.9.2 OUTHOLD, Error Processing
91
A 3.3.9.3 GETOUTINFO_RS422, Request Data Selection
91
A 3.3.9.4 Out_Rs422
91
A 3.3.9.5 OUTADD_RS422, Selection of Data Additional Values
92
A 3.4 Error Messages
93
Advertisement
MICRO-EPSILON ILD 1220-50 Operating Instructions Manual (94 pages)
Brand:
MICRO-EPSILON
| Category:
Accessories
| Size: 3 MB
Table of Contents
Table of Contents
3
1 Safety
9
Symbols Used
9
Warnings
9
Notes on CE Marking
10
Intended Use
11
Proper Environment
11
2 Laser Safety
12
3 Functional Principle, Technical Data
14
Short Description
14
Auto Target Compensation (ATC)
15
Technical Data
16
4 Delivery
18
Unpacking, Included in Delivery
18
Storage
18
5 Installation
19
Notes for Operation
19
Reflection Factor of the Target Surface
19
Error Influences
20
Light from Other Sources
20
Color Differences
20
Temperature Influences
20
Mechanical Vibration
20
Movement Blurs
20
Surface Roughness
21
Angle Influences
22
Optimizing the Measuring Accuracy
23
Mounting, Dimensions
24
Indicator Elements at Sensor
26
Electrical Connections
27
Connection Possibilities for Parametrization
27
Pin Assignment
29
Supply Voltage
30
Laser on
30
RS422 Connection with USB Converter IF2001/USB
31
Analog Output
31
Multifunctional Input
32
Digital Output
33
Sensor Cable
34
6 Operation
35
Getting Ready for Operation
35
Parameterizing Via Web Interface
36
Preconditions
36
Access Via Web Interface
37
Timing, Measurement Value Flux
39
7 Set Sensor Parameter
40
Preliminary Remarks to the Adjustments
40
Overview Parameter
40
Inputs
41
Overview Functions
41
Zeroing
41
Zeroing with Select Key
42
Zeroing with Hardware Input
43
Signal Processing
44
Preliminary Remark
44
Measuring Rate
44
Error Handling
44
Triggering
45
General
45
Value Output Trigger
46
Outputs
47
Overview
47
Digital Output, RS422
48
Values, Ranges
48
Characteristics Digital Output
49
Analog Output Scaling
51
Output Scaling
51
Output Scaling with Key Select
52
Output Scaling Via Hardware Input
53
Calculation of Measuring Value Using Analog Current
54
Characteristics Distance Value and Analog Output
56
Zeroing and Teaching Analog Output
58
Switching Output
59
System Settings
60
General
60
Unit, Language
60
Keylock
60
Load, Save
61
Import, Export
63
Access Authorization
64
8 Digital Interface RS422
66
Measurement Data Format
66
Conversion of the Binary Data Format
67
9 Cleaning
67
10 Liability for Material Defects
68
11 Decommissioning, Disposal
68
12 Service, Repair
68
Appendix
69
A 1 Optional Accessories
69
A 2 Factory Settings
70
A 3 ASCII Communication with Sensor
71
A 3.1 General
71
Overview Commands
73
A 3.3 Commands
76
A 3.3.1 General Commands
76
A 3.3.1.1 Help
76
A 3.3.1.2 GETINFO, Sensor Information
77
A 3.3.1.3 LANGUAGE, Website
78
A 3.3.1.4 RESET, Boot Sensor
78
A 3.3.1.5 ECHO, Switching the Command Reply, ASCII Interface
78
A 3.3.1.6 PRINT, Sensor Settings
79
A 3.3.2 User Level
80
A 3.3.2.1 LOGIN, Change of the User Level
80
A 3.3.2.2 LOGOUT, Change into User Level
80
A 3.3.2.3 GETUSERLEVEL, User Level Request
80
A 3.3.2.4 STDUSER, Set Standard User
80
A 3.3.2.5 PASSWD, Change Password
80
A 3.3.3 Triggering
81
A 3.3.3.1 TRIGGER, Selection
81
A 3.3.3.2 MFILEVEL, Input Pulse Multifunctional Input
81
A 3.3.3.3 TRIGGERCOUNT, Number of Displayed Measurement Values
81
A 3.3.4 Interfaces
82
A 3.3.4.1 Baudrate, Rs422
82
A 3.3.4.2 UNIT, Web Interface
82
A 3.3.4.3 MFIFUNC, Function Selection Multifunctional Input
82
A 3.3.4.4 ERROROUT1, Activate Error Output
82
A 3.3.4.5 ERRORLEVELOUT1, Output Level Digital Output
83
A 3.3.4.6 Errorlimit
83
A 3.3.4.7 Errorhysteresis
83
A 3.3.4.8 Errorouthold
83
A 3.3.5 Handling of Setups
84
A 3.3.5.1 Import
84
A 3.3.5.2 Export
84
A 3.3.5.3 MEASSETTINGS, Load / Save Measurement Settings
85
A 3.3.5.4 BASICSETTINGS, Load / Save Device Settings
86
A 3.3.5.5 SETDEFAULT, Default Settings
86
A 3.3.6 ANALOGSCALE, Scaling the Analog Output
86
A 3.3.7 Key Function
87
A 3.3.7.1 KEYFUNC, Choose Key Function
87
A 3.3.7.2 KEYLOCK, Set Keylock
87
A 3.3.8 Measurement
88
A 3.3.8.1 MEASRATE, Measuring Rate
88
A 3.3.8.2 LASERPOW, Laser Power
88
A 3.3.8.3 MASTERMV, Mastering / Zeroing
88
A 3.3.9 Data Output
89
A 3.3.9.1 OUTPUT, Selection of Measurement Value Output
89
A 3.3.9.2 OUTHOLD, Error Processing
89
A 3.3.9.3 GETOUTINFO_RS422, Request Data Selection
89
A 3.3.9.4 Out_Rs422
89
A 3.3.9.5 OUTADD_RS422, Selection of Data Additional Values
90
A 3.4 Error Messages
91
MICRO-EPSILON ILD 1220-50 Operating Instructions Manual (58 pages)
Intelligent laser-optical displacement measurement
Brand:
MICRO-EPSILON
| Category:
Security Sensors
| Size: 4 MB
Table of Contents
Table of Contents
3
Safety
6
Symbols Used
6
Warnings
6
Notes on Product Marking
6
CE Marking
6
UKCA Marking
7
Intended Use
7
Proper Environment
7
Laser Safety
8
Functional Principle, Technical Data
9
Brief Description
9
Intelligent Surface Control
9
Technical Data
10
Delivery
11
Unpacking, Included in Delivery
11
Storage
11
Structure of the Serial Number
11
Installation
12
Notes on Operation
12
Reflectance of Target Surface
12
Error Influences
12
Ambient Light
12
Color Differences
12
Temperature Influences
12
Mechanical Vibrations
12
Movement Blur
13
Surface Roughness
13
Angular Influences
13
Optimization of Measurement Accuracy
13
Mechanical Fastening, Dimensional Drawing
14
Control and Indicator Elements
15
Zero Setting
15
Electrical Connections
16
Connection Options for Parameterization
16
Pin Assignment
16
Supply Voltage
17
Turning on the Laser
17
RS422 Connection with USB Converter IF2001/USB
17
Analog Output
18
Multifunction Input
18
Switching Output
18
Sensor Cable
19
Operation
20
Getting Ready for Operation
20
Parameterization Via Web Interface
20
Requirements
20
Access Via Web Interface
21
Measurement Configuration
21
Signal Quality
22
System Settings
22
Save Settings
22
Calibration Protocol
22
Programming Via ASCII Commands
22
Time Response, Measurement Value Flow
22
Set Sensor Parameters, Web Interface
23
Preliminary Remarks about the Setting Possibilities
23
Overview of Parameters
23
Inputs
23
Overview of Functions
23
Zeroing
23
Zeroing with the Select Button
24
Zeroing Via Hardware Input
24
Signal Processing
25
Preliminary Remark
25
Measuring Rate
25
Error Handling
25
Triggering
25
General
25
Triggering the Output of Measurement Values
26
Outputs
26
Overview
26
Digital Output, RS422
27
Values, Ranges
27
Behavior of the Digital Output
28
Analog Output
30
Output Scaling
30
Multifunction Input
30
Output Scaling with the Select Button
31
Output Scaling Via Hardware Input
31
Calculation of Measured Value from Analog Current
32
Behavior Distance Value and Analog Output
32
Analog Output, Zeroing and Teaching
33
Error Output
34
Measuring Range
35
Limit Value
35
Data Output
35
System Settings
35
General
35
Unit, Language
36
Key Lock
36
Loading, Saving
36
Import & Export
37
Access Authorization
37
Resetting the Sensor
38
Digital Interface RS422
39
Preliminary Remarks
39
Measurement Data Format
39
Conversion of the Binary Data Format
39
Cleaning
40
Software Support with Medaqlib
41
Disclaimer
42
Service, Repair
43
Service & Repair
43
Decommissioning, Disposal
44
Optional Accessories
45
Factory Settings
46
ASCII Communication with Sensor
47
General
47
Commands Overview
48
Commands
49
General Commands
49
Help
49
GETINFO, Sensor Information
50
LANGUAGE, Website
50
RESET, Booting Sensor
50
ECHO, Switching the Command Reply, ASCII Interface
50
PRINT, Sensor Settings
50
User Level
51
LOGIN, Change of the User Level
51
LOGOUT, Change into User Level
51
GETUSERLEVEL, User Level Query
51
STDUSER, Set Standard User
51
PASSWD, Change Password
51
Triggering
51
TRIGGER, Trigger Selection
51
MFILEVEL, Input Level Multi-Function Input
52
TRIGGERCOUNT, Number of Output Measurement Values
52
Advertisement
Advertisement
Related Products
MICRO-EPSILON ILD 1220-10
MICRO-EPSILON ILD 1220-25
MICRO-EPSILON ILD 1220-100
MICRO-EPSILON ILD 1220-200
MICRO-EPSILON ILD 1220-500
MICRO-EPSILON ILD1700-2LL
MICRO-EPSILON ILD1700-10LL
MICRO-EPSILON ILD1900-2
MICRO-EPSILON ILD1900-25
MICRO-EPSILON ILD1900-50
MICRO-EPSILON Categories
Measuring Instruments
Accessories
Industrial Equipment
Controller
Security Sensors
More MICRO-EPSILON Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL