Sign In
Upload
Manuals
Brands
Meusburger Manuals
Controller
profiTEMP+
Meusburger profiTEMP+ Manuals
Manuals and User Guides for Meusburger profiTEMP+. We have
1
Meusburger profiTEMP+ manual available for free PDF download: Start-Up And Service Instructions
Meusburger profiTEMP+ Start-Up And Service Instructions (38 pages)
Integrated hot runner controller
Brand:
Meusburger
| Category:
Controller
| Size: 12 MB
Table of Contents
Table of Contents
3
Preface
6
Versions Documentation
6
Information about this Manual
6
Disclaimer
6
Terms of Delivery
6
Warranty Conditions
6
Security
6
Target Group of These Instructions
7
Intended Use
7
Danger and Warning Notices
7
Other Notes
7
Safety Instructions
7
Transportation and Storage
8
Transport
8
Unpacking
8
Storage
8
Lifting and Carrying
8
Disposal
8
Maintenance
8
Service
8
Product Description
9
General Description
9
Components / System Structure
9
Labeling
10
Type Plate
10
Scope of Delivery
10
Structure and Connections
11
Pt+Cur
11
Power Supply
11
Ethernet
11
Fieldbus (Optional)
12
Profinet
12
Ethercat
12
Canopen/Rs485
12
Technical Data
13
Pt+Io
13
Power Supply
13
Measuring Inputs for Leakage Current Transformers
14
Digital Inputs
14
Digital Output
14
Technical Data
14
Pt+Rack
15
CAN (System Bus)
15
Power Supply Electronics
15
Heating Outputs
15
Thermocouple Inputs
16
Technical Data
16
Pt+Htc
16
Measuring Inputs External Cold Junction
17
Technical Data
17
Installation and Start-Up
19
Schematic Representation
19
Mechanical Installation
20
Pt+Rack Installation in Control Cabinet
20
Slide-In Cards Pt+Htc 06/15 / Fitting Cover Plates
21
SLIDE-IN CARD Pt+Htc 06/15
21
Cover Plates
21
Pt+Cur
21
Pt+Io
21
Pt+ ERJ
21
Residual Current Transformer RCT
21
Electrical Installation
22
Preparation Pt+Rack for Wiring
22
Power Loss
22
Power Supply Electronics
23
Pt+Cur & Pt+Io
23
Mains Voltage for Heating Outputs
23
Protective Ground
24
Sensor / Heating Connection
25
Sensor Connection Cable
25
Heating Connection Cable
26
CAN-Bus (Intern)
27
Terminating Resistor
28
Setup and Service
29
Installation and Setup
29
Pt+Io
29
Pt+Erj
29
Pt+Htc 06/15
29
Pt+Cur
29
Replacing Individual Components and Setup
30
Pt+Cur
30
Pt+Io
30
Pt+Htc 06/15
30
Change the Fuse to Pt+Htc 06/15
31
Add Pt+Htc 06/15 (Extend Number of Zones)
31
Remove HTC 06/16/S (Reduce Number of Zones)
31
Firmware Update
31
Update Via Flexotempmanager
31
Update Via USB
31
Troubleshooting and Elimination
32
Overview of Status Display
32
Cause of Error and Troubleshooting
32
Timeout/Slave Does Not Respond
32
Timeout Nodeguarding
32
Incorrect Slave Type in Project Planning
32
Phase/Fuse Faults
33
Residual Current
33
Current too High
33
Thyristor Alarm
33
Complete Failure of Heater
33
Potential Error
33
Sensor Break
33
6.2.11 Sensor Polarity Reversal
34
6.2.12 Sensor Short Circuit
34
6.2.13 Pt+Cur SWITCHED off
34
6.2.14 Actuator Switched off
34
Heat Sink Temperature too High
34
Appendix
35
Addressing the Components with CAN Interface
35
Accessories
36
Declaration of Conformity
36
Advertisement
Advertisement
Related Products
Meusburger profiTEMP IM
Meusburger PSG profiTEMP
Meusburger PSG profiTEMP+
Meusburger PSG profiTEMP Dt Series
Meusburger PSG profiTEMP De Series
Meusburger PSG profiTEMP Tt Series
Meusburger PSG profiTEMP Te Series
Meusburger profiTEMP TM
Meusburger PSG profiTEMP 036 Dt
Meusburger PSG profiTEMP 060 Tt
Meusburger Categories
Controller
Indoor Furnishing
Cutter
Measuring Instruments
Control Panel
More Meusburger Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL