Table of Contents
Table of Contents
3
Preface
7
Chapter 1
8
Maxpac Input/Output Subsystem
8
Overview
8
Model IOP I/O Subsystem
8
Cabinet
8
Chassis Assembly
9
DPU Mounting
11
I/O Modules
11
I/O Module Types
12
Power Supply
13
Field Termination Options
14
Local Terminations (Standard)
14
Remote Terminations (Option)
14
Installing Model IOP I/O Equipment
14
Sequence of Mounting Operations
15
Mounting I/O Chassis Assemblies
15
Cabling, Power, and Ground Wiring
16
Supplying 24V Power to the I/O Modules
16
Interconnecting Adjacent I/O Chassis
17
Module Mounting Considerations
18
I/O Modules
18
DPU Modules
18
Module Addressing
19
Backup Configuration Options
20
Shared Configuration
20
Redundant Configuration
21
Mixed Configuration
21
Remote I/O
22
Specifications
24
Environment
24
I/O Bus
24
Inputs/Outputs
24
Chapter 2
25
Analog Input Modules Isolated Input Module IOP301
25
Overview
25
LED Indication
25
Bus Address
26
Jumper Configuration
26
Program Resistors
26
Module Operation
28
Diagnostics
29
Module Specifications
30
Field Wiring
31
Field Wiring for Redundant Modules with Common Transmitter
32
Chapter 3
34
Analog Input Modules 4-20 Ma Input Module IOP302 Voltage Input Module IOP305
34
Overview
34
LED Indication
34
Bus Address
35
Jumper Configuration
35
Module Operation
35
Diagnostics
37
Module Specifications
37
Field Wiring for IOP302
38
Field Wiring - IOP 305 Analog Input Module
39
Field Wiring for Redundant Modules with Common Transmitter
40
Chapter 4
41
Analog Input Modules 3 Wire RTD Module IOP303
41
Overview
41
LED Indication
41
Bus Address
42
Jumper Configuration
42
Module Operation
42
Diagnostics
44
Module Specifications
44
Field Wiring
45
Field Wiring for Redundant Modules with Common RTD
46
Chapter 5
47
Analog Input Modules TC Module IOP304
47
Overview
47
LED Indication
47
Bus Address
48
Jumper Configuration
48
Cold Junction Compensation
48
Module Operation
48
Diagnostics
49
Module Specifications
50
Field Wiring
51
Field Wiring for Redundant Modules with Common TC
52
Chapter 6
53
Analog Output Modules 4-20 Ma Output Module IOP320
53
LED Indication
53
Bus Address
54
Jumper Configuration
54
Module Operation
55
Diagnostics
56
Module Specifications
57
Field Wiring
58
Field Wiring for Redundant Modules with Common End Element
59
Chapter 7
60
Digital Input Modules 24V Common Input Module IOP330 48V Common Input Module IOP331
60
Overview
60
LED Indication
60
Bus Address
61
Module Operation
61
Module Specifications
62
Field Wiring
63
Field Wiring for Redundant Modules with Common DI
64
Chapter 8
65
Digital Input Modules 24V DC Isolated Input Module IOP334 120V AC/DC Isolated Input Module IOP332 240V AC/DC Isolated Input Module IOP333
65
Overview
65
LED Indication
65
Bus Address
66
Jumper Configuration
66
Module Operation
66
Module Specifications
67
Field Wiring
68
Field Wiring for Redundant Modules with Isolated DI
69
Chapter 9
70
Digital Input Modules Pulse I/O Module IOP335
70
LED Indication
70
Bus Address
70
Jumper Configuration
70
Module Operation
72
Diagnostics
72
Module Specifications
73
Field Wiring
74
Chapter 10
75
Digital Output Modules Form A/B Relay Module IOP351 Form C Relay Module IOP350
75
Overview
75
LED Indication
75
Bus Address
76
Jumper Configuration
76
Module Operation
76
Module Specifications
77
Field Wiring - IOP 351
79
Wiring - IOP350
80
Field Wiring for Redundant Modules with Common End Element
81
Chapter 11
82
Bus Extender Unit Module IOP371
82
Overview
82
BEM Front Panel
83
LED Indication
83
Link Test
83
Bus Address
83
Jumper Configuration
83
DPU Compatibility
85
I/O Bus Loading
85
BEM Operation
86
Optical Cabling
88
Model 564 and Maxpac I/O Compatibility
88
Termination Requirements
88
Redundant Configuration Approaches
88
Four Configuration Approaches
88
Configuring Remote I/O Only
89
Configuring Local Common I/O
89
Configuring Mixed Common and Redundant I/O
89
Single DPU Configurations
90
BEM Configuration Considerations
92
Calculating Link Capacities
92
Ensuring Link Availability
93
Detecting Failover Conditions
94
Cabling Recommendations
94
Specifications
94
Advertisement
Advertisement
Related Products
metso automation DPU Bus
metso automation Categories
Control Unit
Valve Positioners
Controller
Home Automation
Switch
More metso automation Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL