Sign In
Upload
Manuals
Brands
Megger Manuals
Test Equipment
KMK 8
Megger KMK 8 Manuals
Manuals and User Guides for Megger KMK 8. We have
1
Megger KMK 8 manual available for free PDF download: User Manual
Megger KMK 8 User Manual (145 pages)
Cable Fault Locator
Brand:
Megger
| Category:
Test Equipment
| Size: 3 MB
Table of Contents
Table of Contents
4
Introduction
7
Application
7
Application Guide for Fault Location
10
Active Bridge
11
Passive Wheatstone-Bridge
11
End to End Synchronic Measuring Method
11
General Features
12
Keyboard, Sockets and Leds
13
Connectors & Balance Controls
16
Operating Instructions
17
Start up and General Rules
17
Calibration
18
Storage and Recall of Measuring Results
20
Provided Special Actions after Measurements
21
Tdr Measurements
23
Principles of Operation
23
Settings before Measurement
25
Test of a Single Pair
28
Waveform Evaluation
29
Location of Cross Talk Points
30
Comparison of Two Pairs
30
Comparison to Stored Result
31
Application Guide (General Hints for TDR)
32
Typical Waveforms
33
Obtaining the Missing V/2
37
Active Bridge
41
Interference Voltage Measurement (AC and DC)
41
Resistance Measurements
42
Loop Resistance Measurement (2 WIRE)
42
Loop Resistance Measurement (2-WIRE & GND)
44
Resistance Difference Measurement
45
Insulation Resistance Measurement
46
Capacitance Measurements
48
Capacitance Measurement (2 WIRE)
49
Capacitance Measurement (2 WIRE&GND)
50
Capacitive Balance Measurement
52
DC Fault Location with MURRAY Method
53
DC Fault Location with Küpfmüller Method
55
DC Fault Location with 3 Point Method
58
DC Fault Location with Repeated KÜPFMÜLLER Method
60
AC Fault Location with Interruption Measurement
63
AC Fault Location with Repeated KÜPFMÜLLER Method
64
Passive Bridge
65
Principles of Operation
65
Loop Resistance Measurement
65
Insulation Resistance Measurement
65
Resistance Difference Measurement
69
DC Fault Location with MURRAY Method
71
DC Fault Location with 3 Point Method
74
DC Fault Location with Küpfmüller Method
78
AC Fault Location with Küpfmüller Method
82
Capacitive Balance Measurement
86
End to End Synchronous Measurement
89
Pre Measurements
93
Survey of Pair Condition
93
AC DC Voltage Measurement
95
Loop Resistance Measurement
96
Insulation Resistance Measurement
97
DC Current Measurement
98
Cable Temperature Measurement
99
Automatic Test Sequences
101
Automatic Quick Test
101
Automatic Quality Test
102
Battery Manager
103
Battery Capacity Indication
103
Normal Charging
103
Fast Charging
104
Regenerating Charge Process
104
Initial Charging
104
Automatic Battery Switch-Off
105
Battery Life Expectancy
105
Charging During Measurement
105
Usb Ports
107
Result Transfer from KMK 8 to USB Flash Drive
108
Result Transfer from USB Flash Drive to KMK 8
109
Status & Options
111
Upgrade (Kmk8U.exe)
113
Demoprogramm (Kmk8D.exe)
115
Settings
117
Loop Closing Device Klc 8
119
Intelligent Slave Kmk 80S (Optional)
121
Specifications
123
General Specifications
123
Tdr
125
Active Bridge
127
Passive Bridge
131
Pre Measurements
135
Quick Test
139
Quality Test
140
Scope of Delivery and Optional Accessories
143
Advertisement
Advertisement
Related Products
Megger KF-LAB Mk II
Megger KF-875
Megger 1003-062
Megger 1003-064
Megger 1003-066
Megger 1003-068
Megger 1003-428
Megger 1003-430
Megger Categories
Test Equipment
Measuring Instruments
Multimeter
Security Sensors
Receiver
More Megger Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL