Sign In
Upload
Manuals
Brands
Littelfuse Manuals
Recording Equipment
SE-330AU
Littelfuse SE-330AU Manuals
Manuals and User Guides for Littelfuse SE-330AU. We have
3
Littelfuse SE-330AU manuals available for free PDF download: Manual
Littelfuse SE-330AU Manual (82 pages)
NEUTRAL-GROUNDING-RESISTOR MONITOR
Brand:
Littelfuse
| Category:
Monitor
| Size: 18.84 MB
Table of Contents
Table of Contents
2
1 General
4
Modern Resistance-Grounded Systems
4
Series NGR Monitoring
4
NGR Sensitive Open and Short Detection
6
2 Operation
6
Settings
6
GF Trip Time
6
GF Trip Level
6
VN Trip Level
6
Table 1. Typical Values for Tripping Systems (SE-330 and SE-330HV)
8
Table 2. Typical Values for Tripping Systems
9
Table 3. Ground-Fault Trip Levels for Selected Cts (SE-330 and SE-330HV)
10
Pulse Period Adjustment (SE-330 Only)
11
Configuration Settings
11
Relay K1 Function (S1, SE-330 ONLY)
11
Trip-Relay Mode and Trip-Memory Mode (S2, SE-330 and SE-330HV ONLY)
11
FIGURE 1. SE-330 Configuration Switches
11
FIGURE 2. SE-330HV Configuration Switches
11
FIGURE 3. SE-330AU Configuration Switches
11
Ground-Fault-Trip Latch (S3)
12
Resistor-Fault-Trip Latch (S4)
12
Sensing-Resistor Selection (S5)
12
Frequency (S6)
12
Upgrade Mode (S8)
12
Resistor-Fault Trip Time
12
Resistor-Fault Trip Level
12
Geo-Magnetic Filter
12
Calibration
12
Pulsing Operation (SE-330 Only)
13
Trip Indication and Reset
13
Remote Operation
14
Relay K1 LED
14
Unit Healthy Output
14
Diagnostic LED
14
Enhanced Health Status
14
Analog Output
14
FIGURE 4. Analog-Output Connections
14
3 Installation
15
Series
15
FIGURE 5. SE-330 Connection Diagram
16
FIGURE 6. SE-330HV Connection Diagram
17
FIGURE 7. SE-330AU Connection Diagram
18
FIGURE 8. SE-330 Outline and Panel-Mounting Details
19
FIGURE 9. SE-330 Outline and Surface-Mounting Details
20
FIGURE 10. SE-IP65CVR-G Weatherproof Cover Outline
21
FIGURE 11. SE-IP65CVR-G Weatherproof Cover Installation
22
Sensing Resistor
23
FIGURE 12. ER-600VC Sensing Resistor
24
FIGURE 13. SE-MRE-600 Moisture-Resistant Enclosure Outline
25
FIGURE 14. ER-600VC Installed in SE-MRE-600
26
FIGURE 15. ER-5KV Sensing Resistor
27
FIGURE 16. ER-5WP Sensing Resistor
28
FIGURE 17. ER-15KV Sensing Resistor
29
FIGURE 18. ER-25KV Sensing Resistor
30
FIGURE 19. ER-35KV Sensing Resistor
31
FIGURE 20. ER-72KV Sensing Resistor Outline
32
FIGURE 21. ER-72KV Sensing Resistor Mounting Details
33
FIGURE 22. ER-1000HV Sensing Resistor
34
Ground-Fault CT
35
FIGURE 23. ER-1000HV Simplified Connection Diagram
35
FIGURE 24. ELCT5-88 and ELCT30-88 Ground-Fault Current Sensors
36
FIGURE 25. ELCT5-31 and ELCT30-31 Ground-Fault Current Sensors
37
FIGURE 26. EFCT-1 Ground-Fault Current Sensor
38
FIGURE 27. SE-CS30-70 Ground-Fault Current Sensor
39
FIGURE 28. EFCT-26 and SE-CS30-26 Ground-Fault Current Sensors
40
FIGURE 30. PGA-0520 Analog Percent Current Meter
41
Isolated Ground Connection
42
Pulsing Connection (SE-330 Only)
42
FIGURE 31. Simplified Isolated-Ground Connection
42
FIGURE 32. Simplified Pulsing Connection
42
4 Data Interfaces
43
SD Card
43
Datalogging
43
Firmware Upgrade
43
USB Interface
43
Network Communications
44
5 Troubleshooting
45
6 Technical Specifications
47
Series (Unless Otherwise Stated)
47
Sensing Resistors
52
Current Sensors
53
7 Ordering Information
55
8 Warranty
58
9 Test Procedures
58
Resistor-Fault Tests
58
Calibration, Open and Short Tests
58
Voltage Test (SE-330 and SE-330AU Only)
59
Voltage Test (SE-330HV Only)
60
Sensing-Resistor Test
60
Analog-Output Test
60
Ground-Fault Performance Test
60
FIGURE 33. Ground-Fault-Test Circuits
61
Appendix A SE-MON330 Reference
62
A1. General
62
A2. Setup
62
TABLE 4. Ground-Fault-Test Record
62
A2.1 Initial Configuration Tab
63
A2.2 Summary Tab
63
FIGURE 34. Communication Tab
64
FIGURE 35. Initial Configuration Tab
64
FIGURE 36. Summary Tab
65
FIGURE 37. Detailed Status Tab
65
FIGURE 38. Configuration Tab
66
A2.3 Detailed Status Tab
67
A2.4 Configuration Tab
67
A2.4.1 Resistor Fault
67
A2.4.2 Ground Fault
67
A2.4.3 Configuration
68
A2.4.4 Networking
68
A2.4.5 SNTP Client
68
A2.5 Event Records Tab
69
FIGURE 39. Event Records Tab
70
A2.6 System Menu
71
A2.6.1 Earth-Fault CT
71
A2.6.2 Voltage Setting
71
A2.6.3 Set Date/Time
71
A2.6.4 Reset to Defaults
71
A2.6.5 Remote Calibration
71
FIGURE 40. System Parameters Menu
72
A2.7 Using Set-Point Assistant
73
FIGURE 41. Set-Point Assistant
73
Appendix B - SE-330, SE-330HV, SE-330AU Revision History
74
Manual Revision History
77
Advertisement
Littelfuse SE-330AU Manual (42 pages)
NEUTRAL-EARTHING-RESISTOR MONITOR
Brand:
Littelfuse
| Category:
Relays
| Size: 6.27 MB
Table of Contents
SE-330AU Neutral-Earthing-Resistor Monitor Rev. 4-I
2
Table of Contents
3
General
5
Modern Resistance-Earthed Systems
5
SE-330AU NER Monitoring
5
Operation
6
Settings
6
EF Trip Time
6
EF Trip Level
6
Ntrip Level
6
Configuration Settings
6
Earth-Fault-Trip Latch (S3)
6
Resistor-Fault-Trip Latch (S4)
6
Sensing-Resistor Selection (S5)
7
Frequency (S6)
7
Upgrade Mode (S8)
7
Resistor-Fault Trip Time
7
Resistor-Fault Trip Level
7
Geo-Magnetic Filter
7
Calibration
7
CT Detection
7
Configuration Switches
7
Trip Indication and Reset
8
Remote Operation
8
Relay K1 LED
8
Unit Healthy Output
8
Diagnostic LED
8
Analog Output
8
Analog-Output Connections
8
Typical Values for Tripping Systems
9
Installation
10
3.1 Se-330Au
10
Sensing Resistor
10
Earth-Fault CT
10
SE-330AU Connection Diagram
11
SE-330AU Outline and Panel-Mounting Details
12
SE-330AU Outline and Surface-Mounting Details
13
SE-IP65CVR-G Weatherproof Cover Outline
14
SE-IP65CVR-G Weatherproof Cover Installation
15
ER-600VC Sensing Resistor
16
SE-MRE-600 Moisture Resistant Enclosure
17
ER-600VC Installed in SE-MRE-600
18
ER-5KV Sensing Resistor
19
ER-5WP Sensing Resistor
20
ER-15KV Sensing Resistor
21
ER-25KV Sensing Resistor
22
ER-35KV Sensing Resistor
23
EFCT-1 Earth-Fault Current Sensor
24
SE-CS30-70 Earth-Fault Current Sensor
25
EFCT-26 and SE-CS30-26 Earth-Fault Current Sensors
26
RK-332 Remote Indication and Reset
27
PGA-0520 Analog Percent Current Meter
27
Isolated Earth Connection
28
Simplified Isolated-Earth Connection
28
Data Interfaces
29
SD Card
29
Datalogging
29
Firmware Upgrade
29
USB Interface
29
Network Communications
29
Troubleshooting
30
Technical Specifications
32
6.1 Se-330Au
32
Sensing Resistors
34
Current Sensors
35
Ordering Information
35
Warranty
36
Test Procedures
37
Resistor-Fault Tests
37
Calibration and Open Test
37
Voltage Test
37
Sensing-Resistor Test
37
Analog-Output Test
37
Earth-Fault Performance Test
38
Earth-Fault-Test Circuits
38
Earth-Fault-Test Record
38
Appendix A SE-330AU Revision History
39
Littelfuse SE-330AU Manual (16 pages)
SE-330 Series MODBUS/TCP INTERFACE
Brand:
Littelfuse
| Category:
Recording Equipment
| Size: 0.88 MB
Table of Contents
Table of Contents
3
1 General
5
Error Responses
6
SE-330 Database
6
Network Status and Indication
6
2 Modbus Protocol
5
Protocol Setup
5
Error Checking
5
Function Codes Supported
5
Read Input/Holding Registers (Code 4/3)
5
3 Data Records
6
Top View of SE-330 (SE-330-X3-XX) with Dual RJ-45 Ethernet Network Communications
7
Dual Fiber SC Ethernet Network Communications
8
Appendix Amodbus Register Table
9
4 Specifications
16
Appendix B SE-330 Series (New Revision) Modbus/Tcp Interface Revision History
16
Advertisement
Advertisement
Related Products
Littelfuse SE-330HV
Littelfuse SE-330
Littelfuse SE-703
Littelfuse SE-601
Littelfuse SB5032-011-0
Littelfuse SB5032-211-0
Littelfuse SB5032-311-0
Littelfuse SB5060-001-0
Littelfuse SB5060-021-0
Littelfuse SB5060-201-0
Littelfuse Categories
Relays
Monitor
Switch
Microphone
Microcontrollers
More Littelfuse Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk