Sign In
Upload
Manuals
Brands
LI-COR Manuals
Measuring Instruments
LI7200RS
LI-COR LI7200RS Manuals
Manuals and User Guides for LI-COR LI7200RS. We have
2
LI-COR LI7200RS manuals available for free PDF download: Instruction Manual
LI-COR LI7200RS Instruction Manual (320 pages)
Enclosed CO2/H2O Gas Analyzer
Brand:
LI-COR
| Category:
Measuring Instruments
| Size: 29 MB
Table of Contents
Table of Contents
7
Section 1. Overview of the Instrument
15
What's What
15
LI-7200RS Sensor Head
16
Head Cable Assembly
16
Gas Analyzer Accessories
17
LI-7550 Analyzer Interface Unit
19
Flow Module
21
The Smartflux® 2 System
23
Brainboxes SW-508 Network Switch
25
Software
26
Windows Interface Application Software
26
Eddypro® Software
26
File Viewer Software
26
Fluxsuite® Software
26
Tovi™ Software
26
Enclosures and Accessories
27
Pre-Configured Biomet System Enclosure
27
Eddy Covariance System Enclosure
28
Power Distribution Kit
28
Auxiliary Sensor Interface
28
Sonic Anemometer Cables and Mounting Hardware
29
Gill Windmaster/Pro and R3
29
Gill HS-50 and R3-50
30
Campbell Scientific CSAT3
31
Campbell Scientific CSAT3B
31
Metek Multipath Class a
32
Metek Multipath Cage
33
RM Young 81000X
34
Section 2. Initial Assembly
35
Preparing the Gas Analyzer
35
Installing the Flow Module Tubing
35
Attaching the Intake Tube
37
Installing the 2-Micron Particulate Filter
39
Installing the Air Inlet
40
Connecting the Analyzer Data Cables
42
Connecting the Flow Module Data Cable
43
Installing the LI-7550 USB Drive
43
Preparing the Enclosure
44
Preparing the Smartflux System and Network Switch
45
Install the USB Drive
45
Connect the GPS Antenna Cable
45
Connect Power Wires and the Ethernet Cable to the Smartflux System
46
Connect Power Wires to the Brainboxes Network Switch
46
Installing the Smartflux System and Network Switch
47
Connecting Component Power Wires
48
7900-050 Eddy Covariance System Enclosure
48
7900-126 Biomet Data Acquisition System Enclosure
48
12 VDC Power Supply with no Data Retention Module
53
24 VDC Power Supply with the TDK-Lambda DC-DC Converter
55
Connecting Gas Analyzer and Flow Module Power Wires
58
Connecting Ethernet Cables
59
Connecting Sonic Anemometer Data and Power Cables
60
Gill Windmaster or Windmaster Pro
60
Gill HS-50 or R3-50
61
Campbell Scientific CSAT3
62
Campbell Scientific CSAT3B
63
Metek Cage or Class-A
64
RM Young 81000X
65
Section 3. Initial Configuration
67
Configuring Gas Analyzer Settings
70
Setting the System Clock
70
Setting the Operating Temperature Range
71
Additional Eddy Covariance Options
72
Connecting a LI-COR Biomet Data Acquisition System
72
Connecting a Sutron 9210 or Campbell CR3000, CR1000, or CR6
72
Connecting an LI-7700
75
Connecting to Fluxsuite
76
Connecting to a Data Repository
77
Connecting an LI-8100A System
79
Connecting a Phenocam Camera
80
Configuring the System for Cellular Communication with the RV50X
81
Section 4. Field Installation
83
Mounting the Gas Analyzer and Sonic Anemometer
83
Site Considerations
83
Installing the Head Mounting Post
84
Mounting the Sensor Head
84
Securing the Intake Tube
84
Mounting with Mast-Style Anemometers
88
Mounting with C-Clamp Style Anemometers
89
Mounting the LI-7550 and the Flow Module
90
Mounting the GPS Antenna
91
Securing the Sensor Head Cables and Tubing
91
Collect Data on the Setup
93
Site Information
93
Sonic Anemometer North Offset
94
Air Inlet Position
94
Intake Tube Parameters
95
Section 5. Configuring the Eddy Covariance System
97
Configuring the Site Setup
97
Configuring the USB Log File
97
Checking the Bandwidth
98
Entering the Site Description
98
Entering Anemometer Information
101
Entering CO2/H2O Analyzer Information
104
Selecting CO2/H2O Log Variables
105
Configuring the Air Intake
105
Configuring the Flow Module
106
Entering CH4 Analyzer Information (Optional)
107
Begin Logging Data
108
Verifying Flux Computations
108
System Diagnostics
109
Clock
110
Sonic Data Collection
112
Eddypro
114
Smartflux 2/3 USB Storage
114
Fluxsuite
115
Data Repository
116
Database Size
116
Tips for Success
117
Site Maintenance Schedule
117
Filtering the Air Inlet
118
Cleaning the Optics
119
Operating in Environments with High-Frequency Vibrations
119
Operating in Cold Weather (<5 °C)
119
Operating in Extreme Humidity
119
Adding a Muffler to the Air Outlet
121
Saving the Configuration File
122
Exchanging Sensor Heads
122
Moving the Smartflux 2 System from One IRGA to Another
123
Section 6. Viewing and Evaluating Data
125
Logged Data Files
126
The Raw Data Folder
126
The Results Folder
129
The Daqm Folder
129
The Images Folder
130
The ICOS CSV Folder
130
Viewing Data in Fluxsuite Software
130
Automatic File Management
130
Copying Data Files from USB Storage
131
Using the Download Utility
131
Using an SFTP Application
133
Viewing Raw Logged Data
134
In the LI-7X00 File Viewer
134
In a Text Editor
136
Viewing Processed Data from the Eddypro Output
137
Evaluating Long-Term Data in Tovi™ Software
138
Section 7. Eddypro Processing on the Smartflux System
139
Express Processing
140
Advanced Processing
140
Configuring the Smartflux System
141
Planar Fit, Spectral Corrections, and Timelag Optimization in the Smartflux System
143
Advanced Processing Options
145
Loading a Smartflux Configuration File
148
Section 8. Troubleshooting
149
LI-7200/RS Is Identified as an LI-7500A/RS in the Software Interface
149
Gas Analyzer will Not Power on or Repeatedly Powers on and off
149
Problems with the Smartflux 2 System
150
System Powers On/Off Unpredictably or Not Powering the Anemometer
150
System Not Visible on the Network (Cannot Connect)
150
System Not Connected to the Sonic Anemometer
151
USB Flash Drive Not Working Properly
151
Results Are Not Identical to Eddypro Desktop Results
152
Smartflux Status Server Errors
152
Ethernet Connection Problems
152
Instrument Not Visible in Software
153
RS-232 Serial Connection Problems
153
Port in Use or Does Not Exist
153
Not Able to Connect Successfully
153
Parse Error
154
Instrument Software Is Unresponsive
154
Issues with Gas Analyzer Measurements
155
Bad Temperature Readings
155
Bad Pressure Readings
155
Absorptances Make Sense, Densities Don't
156
Readings very Noisy
156
Flow Restrictions
156
Gas Analyzer Diagnostics
159
Diagnostic Value in Data Files
159
CO2 Signal Strength
161
Delta Signal Strength
162
Transfer Functions and Signal Processing
163
Diagnostics in Eddypro on the Smartflux System
164
Gas Analyzer Diagnostics in Eddypro
164
Sonic Anemometer Diagnostics
165
Section 9. Maintenance
169
Cleaning the Gas Analyzer Optical Path
169
Replacing Smartflux 2 System Fuses
171
Replacing the LI-7550 Fuses
173
Power Supply Fuse
173
Accessory Fuse
174
Replacing the Internal Chemicals
174
Cleaning the Intake Cap and Screen
176
Cleaning the 2-Micron Intake Filter
177
Replacing the Thermocouples
178
Leak Test
179
Flow Module Maintenance
180
Changing the Fuse
180
Software Updates
181
Embedded Instrument Software
182
Windows Interface Software Update
184
User Calibration
185
How Stable Are Zero and Span
186
Checking the Zero
186
Checking the Span
187
Step-By-Step Calibration Instructions
188
Considerations for Setting the Secondary Span
191
What Actually Happens
193
Section 10. Software Reference
195
Connection Options
195
Connect over Ethernet
195
Connect over RS-232 Serial
198
Run Disconnected
200
Dashboard
200
Instrument Information and Data Logging Status
201
Instrument Performance and Connection Status
203
Graphs
204
Data Display
205
Other Software Settings
206
Flow Module Options
206
Flow Module Interior Control Panel
208
Settings
209
Menu Overview
215
Calibration Window
225
PC Logging
230
Diagnostics
231
Charting
238
Configuration Files
240
Section 11. Theory of Operation
241
Appendix A. Sonic Anemometer Connection Options
249
USB Connections for Configuration
249
Additional Digital Data Cable Options
257
Appendix B. 7550-101 Auxiliary Sensor Interface
271
Appendix C. Pin Assignments
273
Appendix D. Suppliers
275
Appendix E. Configuration Grammar
279
Appendix F. Specifications
303
Advertisement
LI-COR LI7200RS Instruction Manual (226 pages)
Enclosed CO2/H2O Gas Analyzer
Brand:
LI-COR
| Category:
Measuring Instruments
| Size: 12 MB
Table of Contents
A Bit of History
6
Table of Contents
7
Section 1. General Information
13
What's What
14
Spare Parts Kits
14
Cables
15
Calibration Certificate
17
The Smartflux® 2 System
17
LI-7550 Analyzer Interface Unit
18
Section 2. Initial Setup
21
First Things First
21
Installing the Gas Analyzer and Components
24
Mounting the LI-7550 Analyzer Interface Unit
24
Using the Insulated Intake Tube
25
Using the Heated Intake Tube
26
Intake Tube Dimensions
29
Installing the 2-Micron Dust Filter
29
Installing the Intake Cap
30
Mounting the Sensor Head and Intake Tube
32
Connecting the Sensor Head Cable
35
Tips for Success
36
Filtering
36
Cleaning
36
Vibrations
36
Operation in Cold Weather (<5 °C)
37
Extreme Humidity
37
Using the 7550-101 Auxiliary Sensor Interface
39
Mounting the ASI
39
Terminal Connections
40
Electrical Connections
41
Connecting Sensors to the ASI
41
Section 3. Operation
43
Installing the PC Software
43
Connecting with the Analyzer
43
Connect over Ethernet
43
Connect over Serial
45
Run Disconnected
46
Dashboard
48
Instrument Information and Logging
49
Instrument Status and Connectivity
50
Eddy Covariance Flux Graphs
52
Data Display
55
Configuring Eddy Covariance Measurements
58
Eddy Covariance Checklist
58
System Clock
61
Configuring the USB Log File
62
Entering the Site Description
63
Entering Anemometer Information
64
Entering CO2/H2O Analyzer Information
71
Configuring the Flow Module
73
Entering the Intake Tube Dimensions
74
Configure the Heated Intake Tube
75
Entering LI-7700 Information
75
Connect with an LI-7700
76
Enter Analyzer Information
76
Select Variables
77
Entering Biomet System Information
78
Connecting to a Datalogger
78
Connecting with the Smartflux or Smartflux 2 System
80
Begin Logging Data
86
About Data Files
87
About File Compression (USB Logging Only)
87
Transferring Logged Data
88
Eddypro Processing Modes on the Smartflux System
90
Express Processing
90
Advanced Processing
90
Smartflux Results Files
99
Section 4. User Calibration
101
How Stable Are Zero and Span
101
Checking the Zero
102
Checking the Span
103
Zero H2O
107
Secondary CO2 Span
108
Secondary H2O Span
109
What Actually Happens
109
Section 5. Maintenance
113
Eddy Covariance Site Maintenance Schedule
113
Cleaning the Optical Path
115
Opening the Optical Bench
115
Replacing the Internal Chemicals
116
Cleaning the Intake Cap and Screen
119
Maintaining the Filter
119
Replacing the Fuses
120
Power Supply Fuse
121
Accessory Fuse
121
Replacing the Thermocouples
121
Leak Test
123
Software Updates for Gas Analyzers
123
Embedded Instrument Software
124
Windows Software Update
126
Flow Module Maintenance
127
Section 6. Troubleshooting
131
LI-7200/RS Is Identified as an LI-7500A/RS in the Software Interface
131
Power on Problems
131
Problems with the Smartflux 2 System
132
Ethernet Connection Problems
133
Instrument Not Visible in Software
133
RS-232 Serial Connection Problems
134
Port in Use or Does Not Exist
134
Not Able to Connect Successfully
134
Parse Error
134
Instrument Software Is Unresponsive
135
Bad Temperature Readings
135
Bad Pressure Readings
136
Bad CO2 or H2O Readings
136
Section 7. Software Reference
139
Settings
139
Time
139
Network
142
Manual
145
Advanced-Chopper Housing Temperature
146
Integration
146
Menu Overview
148
Auxiliary Inputs
148
Outputs
150
RS-232 Output
151
Ethernet Output
152
DAC Configuration
153
SDM Output
154
Delay Time
156
Total System Delay Examples
157
Bandwidth
157
Diagnostic Value
158
Calibration Window Overview
159
Signal Strength Tab
160
Coefficients Tab
160
Manual Tab
161
History Tab
162
Changing Sensor Heads
162
By Hand
162
Automatic
162
PC Logging
164
Begin Logging Data
165
Note on Data Output Rates
165
Diagnostic Messages
165
General Indicators
166
Test Point Values
167
Waveform
170
Configuration Files
172
Section 8. Theory of Operation
173
Relating Absorption to Concentration
173
Measuring Absorptance
174
Cross Sensitivity
175
Zero Drift
175
Equation Summary
176
LI-7200RS Implementation
178
A Note about Pressure and Temperature
179
Diagnostics
179
CO2 Signal Strength
179
Delta Signal Strength
182
LI-7200RS Transfer Functions and Signal Processing
183
Appendix A. Specifications
185
Command Summary
198
Advertisement
Related Products
LI-COR li-7200
LI-COR LI-7700
LI-COR LI-7500
LI-COR LI-7820
LI-COR LI-7810
LI-COR LI-7825
LI-COR LI-8100A
LI-COR LI-180
LI-COR LI-8100
LI-COR LI-870
LI-COR Categories
Measuring Instruments
Laboratory Equipment
Accessories
Data Loggers
Scanner
More LI-COR Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL