Sign In
Upload
Manuals
Brands
Leviton Manuals
Security System
Omni Pro II
Leviton Omni Pro II Manuals
Manuals and User Guides for Leviton Omni Pro II. We have
2
Leviton Omni Pro II manuals available for free PDF download: Owner's Manual, Installation Manual
Leviton Omni Pro II Owner's Manual (124 pages)
Omni Pro II automation Control & Security System
Brand:
Leviton
| Category:
Security System
| Size: 1 MB
Table of Contents
Table of Contents
4
Introduction
10
Underwriter's Laboratories (UL) Listing
10
Overall Description
11
Console Operation
11
Normal Top-Level Display
12
Display Menus
12
Main Menu
13
Enable or Disable Console Beeper Locally at the Console
13
Error Beeps
13
Trouble Beeps
13
Confirmation Beep
14
Cancel
14
Time out
14
Areas
14
Omnipro II Maintenance
14
Security System Operation
15
Disarming the Security System and Silencing Alarms
15
Arming the Security System
15
Using Shortcut Keys
16
Quick Arm
16
What Happens When You Arm the Security System
17
Exit Error
17
Bypassing Zones
18
Auto-Bypass
18
Restoring Zones
18
What to Do When You Come Home
19
What Happens When the Alarm Is Activated
19
Burglar Alarm Activated
19
Fire Alarm Activated
20
Gas Alarm Activated
20
Emergency Keys
20
Police Emergency
21
Fire Emergency
21
Auxiliary Emergency
21
Duress Code Entered or Duress Alarm Activated
21
Alarm Reset
21
Alarm Cancel
21
Trouble Indications
22
Codes
22
Master Code
22
Manager Code
23
User Code
23
Duress Code
23
Panic Switches
23
Area Arming
23
Testing Your System
25
Control
26
Control Commands
26
About UPB
26
LEVITON Lighting Control (HLC) Format
27
About Rooms
27
About Room Controllers
27
Room Controller LED Indicators
27
About House Controllers
28
About Vizia RF Z-Wave
28
Vizia RF Z-Wave Format
28
About Centralite
29
About Lutron Radiora
29
About ALC
30
ALC Module Types
30
About X-10
30
House Codes
30
Unit Numbers
31
Scrolling through Names
32
Controlling Units
32
Controlling a Room of HLC Lighting
32
Configuring Lighting Scenes in an HLC Room
32
Controlling Individual Lighting Loads in an HLC Room or UPB Units
33
Controlling Vizia RF Z-Wave
33
Controlling a Room of Vizia RF Z-Wave Lighting
33
Controlling Individual Lighting Loads in an Vizia RF Z-Wave Room
34
Controlling Centralite Units
34
Controlling Radiora Units
35
Controlling ALC or X-10 Units
35
Ramp Command (ALC)
36
Controlling Compose Units
36
Scene Command (Compose)
36
Timed Commands
37
Status of a Unit
37
Internal Flags
37
Controlling Outputs
38
All on / off
38
All Lights on
38
All off
38
Leviton Scene Control
39
Scene 1
39
Scene Commands
39
Scene Set Command
39
Scene on Command
39
Scene off Command
40
UPB Links
40
Activating and Deactivating Links
40
Setting a Link (Lighting Scenes)
40
Executing Phantom Buttons
41
Executing Centralite Scenes
41
Buttons
42
Temperature Control
42
LEVITON RC-Series Thermostats
43
Programmable Energy Saver Modules (Pesms)
44
Freeze Alarms
46
Indoor and Outdoor Temperature
46
Outdoor Temperature
47
Temperature Control of Appliances
47
Temperature Alarms
47
Humidity
47
Status
48
Configuring HLC Devices
48
Configuring HLC Devices Using an Omni Console
48
Configuring HLC Devices Using an Omnitouch Touchscreen
49
Setup Mode for HLC Devices
49
Event Log
52
Show Events
52
Messages
53
Record Memo Message
53
Play Memo Message
53
Clear Text Messages
53
Message
53
Show Message
54
Log Message
54
Clear Message
54
Say Message
54
Phone Message
54
Send Message (Pro-Link)
55
Telephone Control
56
Telephone Interface
56
In-House Phones
56
Remote Phones
56
Phone Access Denied - Remote Lockout
57
Alternate Method
57
Main Menu
57
Control
58
Security
58
GOTO Area
58
Button
58
All
58
Temperature
58
Status
59
Events
59
Message
60
Playing and Recording a Message
60
Paging and Listening
60
Playing and Recording a Custom Phrase
60
Playing and Recording the Address
61
Good-Bye
61
Panic Button over the Phone (# # # # # #)
61
Emergency Dial-Out
62
Digital Dialer
62
Voice Dialer
62
How the Omnipro II Voice Dialer Works
62
What the Omnipro II Voice Dialer Does
62
What You Hear - if Your Omnipro II Calls You
63
Entering the Code
63
PC Access
63
Built-In Ethernet Port
64
Controller IP Address, Port Number, and Encryption Key
64
Omnipro II Ethernet Connections
64
Connecting to Network Via PC Access
64
Dynamic DNS
65
Setup
67
Configuration and Advanced Control Programming (ACP)
67
Set up Codes
67
Authority Level
67
Master
67
Manager
67
User
67
Access Areas
68
Duress Code
68
Set up Time
68
Advanced Control Programming (ACP)
69
Add Programs
70
Show Programs
70
Delete All Programs
71
Edit Programs
71
Edit Programs When
72
Times Programs
72
Button and Event Programs
73
Control Unit / Switch Press Event Buttons
73
Security Mode Event Buttons
74
Zone Event Buttons
75
All On/Off Event Buttons
75
UPB Link Event Buttons
75
Alarm Event Buttons
76
X-10 Event Buttons
76
Miscellaneous Event Buttons
76
Message Event Buttons (Pro-Link)
77
Switch Press Event Buttons (Centralite)
77
Edit Program Command
78
Program Control Commands
78
Unit Toggle Command
79
UPB Blink Command
79
Timed Level Command
79
Program Security Commands
79
Program Button Commands
80
Program All on / All off Commands
80
Program Video Commands
80
Program Temperature Commands
80
Raise or Lower Temperature Command
80
Program Energy Cost
80
Program Message Commands
81
Display Message Without Beeping / Without Beeping or Flashing the LED
81
Beep Command
81
Enable or Disable Beeper Programmatically
81
Edit Program Condition
82
Program Control Conditions
82
Program Security Mode Conditions
82
Program Zone Conditions
82
Program Time Clock Conditions
83
Program Other Conditions
83
Set up Dial
84
Telephone Access
84
Answer Outside Call
84
Remote Commands
84
Rings before Answer
84
Dial Type
84
My Phone Number
84
Dial out Number 1
85
Dial out Numbers 2-8
85
Dial Order
85
Set up Arming
86
Entry Delay
86
Exit Delay
86
Exit Time Restart
86
Unvacated Premises
86
Entry/Exit Chime
87
Perimeter Chime
87
Enable Quick Arm
87
Enable Auto Bypass
87
All on for Alarm
87
Beep on Trouble
87
Set up Miscellaneous
88
High Security Mode
88
Announce Alarms
88
Enable Freeze Alarm
88
Flash for Alarm
88
Console 1-16 Audible Exit Delay
88
House Codes 1-16 Format
89
House Codes 1-16 All off
89
House Codes 1-16 All on
89
Time Clocks
90
Latitude, Longitude, and Time Zone
90
Daylight Savings
91
Controller IP Address
92
Controller Port Number
92
Encryption Key
92
Set up Names
93
Set up Voice
93
Set up Address
94
Audio Control
95
Changing Audio Source
95
Changing Audio Zone
95
Configuring Source and Zone Names
95
Programming Audio Commands
96
Example Programming of Audio Commands
96
Table 1 - Audio Commands
97
Underwriter's Laboratories Requirements
98
Fire Escape Planning
98
Federal Communication Commission Notice
99
Canadian Industry Canada Notice
100
Appendix A - Dial out Planner
101
Instructions to Called Party
102
Appendix B - Text Description Character Codes
103
Appendix C - Voice Description Codes
104
Notes on Custom Phrases
107
Appendix D - Firmware Updates
108
User Settings
112
User Setup
118
Advertisement
Leviton Omni Pro II Installation Manual (86 pages)
Control & Security system
Brand:
Leviton
| Category:
Security System
| Size: 1 MB
Table of Contents
Installation Manual
1
Table of Contents
4
Introduction
8
Planning
8
Installation
9
Controller Hookup
9
Figure 1 - Controller Hookup
10
About Security Zones
11
Burglar Zone Hookups
11
About Fire Zones
12
Figure 2 - Overall Connections Diagram
12
Four-Wire Smoke Detectors
13
Two-Wire Smoke Detectors
13
Figure 3 - Two-Wire Fire Zone Connections
14
Figure 4 - Four-Wire Fire Zone Connections
15
Telephone Connections
16
Digital Subscriber Line (Dsl) Connections
16
Figure 5 - Rj31X Jack Connections
17
Lcd Console Hookup
18
Figure 6 - Dsl Splitter Connections
18
Console Setup
19
Console Address
19
Sounder
19
Key Click
19
Key Backlight
19
Viewing Adjustment
19
Language
19
Exit Setup Mode
19
Figure 7 - Console Connections
20
Sounder Outputs
21
Interior Sounder Hookup
21
Exterior Sounder Hookup
21
Figure 8 - Sounder Connections
22
Controller Outputs
23
Reset Outputs
23
Output Applications
23
General Purpose Switching Applications
23
Sounder Triggering
23
Figure 9 - Resetting Controller Outputs
23
Communicator Outputs
24
Armed" and "Ok to Arm
24
Switched Output
24
Leviton Communicating Thermostats
24
Remote Arm/Disarm Switch
24
Figure 10 - Remote Keyswitch Connections
25
Leviton Thermostats
26
Figure 11 - Leviton Thermostat Connections
26
Programmable Energy Saver Modules
27
Temperature, Outdoor Temperature, and Humidity
28
Figure 12 - Temperature / Humidity Sensor Connections
28
Figure 13 - Pesm Connections
29
Built-In Serial Ports
30
Figure 14 - Rs-232 Connections
30
Built-In Ethernet Port
31
Controller Ip Address, Port Number, and Encryption Key
31
Figure 15 - Rs-485 Connections
31
Controller Ip Address
32
Controller Port Number
32
Encryption Key
32
Omnipro II Ethernet Connections
32
Connecting to Network Via Pc Access
33
Figure 16 - Local Network
33
Figure 17 - Local / Wide Area Network
34
System Power up Procedure
35
Console Check out
35
Telephone Check out
35
Burglar Zone Check out
36
Fire Zone Check out
36
Customer Checkout
36
In Case of Trouble
37
Consoles
37
Controller
37
Digital Communicator
39
Description of Contact ID
39
Description of 4/2 Format
40
3/1 Format
40
Opening and Closing Reports
40
Installer Setup
41
Setup Control
41
X-10 House Code
41
Upb Network ID
41
X-10 3-Phase
42
Output Types
42
Z-Wave Node ID
43
Setup Zones
44
Zone Expansion
44
Zone Resistors
44
Zone Types
45
Latching Zone Types
45
Description of Zone Types
46
Setup Digital Communicator
49
First Phone Number, First Account Number
49
Communicator Type
49
Two-Way Audio
49
Report Open/Close
50
Report Bypass / Restore
50
Automatic Test Time
50
ALARM CODES (4/2 and 3/1 Formats)
50
Setup Areas
51
Setup Areas: Control
51
Setup Areas: Zones
55
Setup Areas: Buttons
55
Setup Areas: Consoles
55
Set-Up Areas: Thermostats
56
Setup Areas: Messages
56
Setup Temperatures
57
Temperature Display
57
Thermostat Type
57
Z-Wave Thermostat Node ID
57
Setup Miscellaneous
58
Installer Code
58
Enable Pc Access
58
Pc Access Code
58
Call Back Phone Number
58
Outside Siren Delay
58
Dial out Delay
59
Alarm Reset Time
59
Arming Confirmation
59
Fire Alarm Verification
59
Supervise Int Sndr
60
Supervise Ext Sndr
60
Enable Emergency Keys
60
Time Display
60
Date Display
60
Ac Power Frequency
60
Dead Line Detect
61
Off Hook Detect
61
Pickup after Hangup
61
Clock Adjustment
61
Model and Software Version
61
Reset System Eeprom
61
Reset System Ram
62
Ethernet Mac Address
62
Setup Expansion
62
Module 1 Type
62
Module 2 Type - Module 4 Type
63
Serial 1 Rate
63
Serial 1 Function
63
Serial 2 - Serial 5 Rate
63
Serial 2 Function
63
Serial 3 Function
64
Serial 4 - Serial 5 Function
64
Serial 6 Rate
64
Setup Zone Options
65
Swinger Shutdown Number
65
Cross Zone Window
65
Zone 1 Options - Zone 176 Options
65
Sia Cp-01 Compliance
66
Minimum Equipment Requirements for a CP-01 Compliant Installation
66
Omnipro II Specifications
67
Underwriter's Laboratories (Ul) Installation Requirements
68
24-Hour Standby Battery Capacity
69
Figure 18 - 24-Hour Standby Connections
69
Smoke Detector Installation Guidelines
70
Appendix A - Contact ID Reporting Format
71
Appendix B - Digital Communicator Code Sheet
72
Appendix C - Zone and Unit Mapping
77
Appendix D - Firmware Updates
78
Advertisement
Related Products
Leviton Omni IIe
Leviton omnilte
Leviton ODSOD-ID
Leviton OC00G
Leviton Opt-X SDX Series
Leviton OSC20-MOW
Leviton OSC10-MOW
Leviton OSC05-MOW
Leviton OneReach
Leviton Categories
Accessories
Switch
Dimmer
Controller
Cables and connectors
More Leviton Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL