Sign In
Upload
Manuals
Brands
Lauper Instruments Manuals
Test Equipment
Mocon Ametek OX-TRAN 2/22
Lauper Instruments Mocon Ametek OX-TRAN 2/22 Manuals
Manuals and User Guides for Lauper Instruments Mocon Ametek OX-TRAN 2/22. We have
1
Lauper Instruments Mocon Ametek OX-TRAN 2/22 manual available for free PDF download: Operator's Manual
Lauper Instruments Mocon Ametek OX-TRAN 2/22 Operator's Manual (83 pages)
Oxygen Transmission Rate System
Brand:
Lauper Instruments
| Category:
Test Equipment
| Size: 1.76 MB
Table of Contents
Safety Information
4
Table of Contents
5
Chapter 1: Introduction
9
Figure 1-1: OX-TRAN Model 2/22 System
9
Features
10
Permeation Test Overview
11
Individual Zero Phase
11
Conditioning the Sample
11
Rezero State
11
Cell Examination State
11
Bypass State
11
Test Completion
11
Report Generation
11
Measuring an Oxygen Transmission Rate
12
Testing Films and Packages
12
Figure 1-2: the OX-TRAN Model 2/22 Test Cell
12
Chapter 2: Setting up
13
Unpacking the System
13
Preparing for Installation
13
Front Panel Parts and Controls
14
Figure 2-1: Front Panel Parts and Controls
14
Figure 2-2: Front Panel Parts and Controls
15
Table 2.1: Front Panel Parts and Controls
15
Back Panel Parts and Controls
16
Figure 2-3: Back Panel Parts and Controls
16
Table 2.2: Back Panel Parts and Controls
16
Test Gas (Oxygen)
17
Carrier Gas (Nitrogen)
17
Gas Distribution Systems
17
Figure 2-4: System Plumbing Connection Diagram
17
Connecting the Gas Lines
18
Setting the Gas Supply Pressures
20
System Outgassing
20
Chapter 3: Preparing for a Test
21
Testing Basics
21
How Barrier Properties Affect Testing
21
Testing very Good Barriers
21
Testing very Poor Barriers
21
Testing Mixed Barriers
22
Testing Moisture Sensitive Barriers
22
Developing Test Methods for Your Films and Packages
22
The Examination Time
22
The Rezero Frequency
22
The Sample Conditioning Time
23
Individual Zero Processing
23
Determining When to Stop a Test
24
Choosing a Test Method
24
The Auto Test Method
24
The Advanced Test Method
24
Saved Test Methods
24
Using Test Sequencing
24
Chapter 4: Using the Instrument Software
25
Software Features
25
Instrument Software Structure and Organization
26
Chapter 5: Testing Flat Film Samples
27
Testing Suggestions
27
Preparing for a Film Test
28
Sample Size
28
Using Masks
28
Orienting the Sample
29
Humidified Testing
30
Filling the Humidifiers
30
Filling the Humidifiers During a Test
30
Figure 5-1: Humidifier Fill Port and Controls
31
Table 5.1: Humidifier Port and Controls
31
Mounting a Sample in the Test Cell
32
Figure 5-2: Mounting a Film Sample
32
Loading and Unloading the Test Cell
33
Figure 5-3: Loading the Test Cell
33
Setting up and Starting a Film Test
34
Monitoring and Controlling a Film Test
34
Chapter 6: Testing Packages
35
Testing Suggestions
35
Preparing the Instrument for a Package Test
36
Figure 6-1: Installing the Package Adapter Cell
36
Package Testing Methods
37
Testing Using Ambient Conditions
37
Package Conditioning
37
Testing Using an Environmental Chamber
37
Package Mounting Methods
38
Mounting Bottles, Cups and Trays Using a Package Plate
38
Figure 6-2: Using a Package Mounting Plate
38
Mounting Pouches and Bags
39
Figure 6-3: Pouches and Bags - Bottom Mount
39
Figure 6-4: Pouches and Bags - Top Mount
39
Supplying a Test Gas
40
Using Ambient Air for the Test Gas
40
Using a Compressed Gas for the Test Gas
40
Figure 6-5: Supplying a Test Gas
41
Setting up and Starting a Package Test
42
Monitoring and Controlling a Package Test
42
Chapter 7: Maintenance
43
Cleaning the Instrument
43
Cleaning the Air Filters
44
Figure 7-1: the Air Filter
44
Cleaning the Test Cells
45
Maintaining the Test Cells
45
Drying out the Humidifiers
45
Test Cell Components and Part Numbers
46
Figure 7-2: Test Cell Components
46
Table 7.1: Test Cell Components
46
Maintaining the Oxygen (Coulox) Sensor
47
Verifying Oxygen Sensor (Coulox) Performance
47
Replacing the Coulox Sensor
47
Maximizing Coulox Sensor Life
47
System Standby
48
System Shutdown for Storage or Repair
48
Chapter 8: Troubleshooting
49
Error Messages and Warnings
49
Troubleshooting Testing Problems
49
Recovering from a Sensor Over-Range Condition
50
Recovering from a Power Failure
50
Chapter 9 Specifications
51
Physical Specifications
51
Environmental Requirements
51
Electrical Requirements
51
Table 9.1: Physical Specifications
51
Table 9.2: Environmental Requirements
51
Table 9.3: Electrical Specifications
51
Gas Supply Requirements
52
Environmental Chamber Specifications
52
Table 9.4: Gas Supply Specifications
52
Table 9.5: Environmental Chamber Specifications
52
Operational Capabilities
53
Table 9.6: Operational Capabilities - Ox-Tran 2/22 Model H
53
Table 9.7: Operational Capabilities - Ox-Tran 2/22 Model L
53
Table 9.8: Operational Capabilities - Ox-Tran 2/22 Model 10X
54
Appendix A: Site Preparation Instructions
55
Appendix B: Spare Parts
59
Appendix C: Warranty and Service Policies
61
Appendix D: Theory of Operation
67
How the Oxygen Sensor Works
67
How the Transmission Rate Is Measured
67
Factors that Affect the Transmission Rate of a Barrier Material
68
Barrier Temperature
68
Test Gas Driving Force
68
Barometric Pressure
68
Relative Humidity
68
How a Humidified Test Gas Is Generated
69
How the Rezero Cell Works
69
How the Auto-Test Method Works
70
How Sequential Testing Works
70
Appendix E: Electrical and Plumbing Diagrams
71
Appendix F: Preparing RH Calibration Standards
77
RH Calibration Equipment
77
Choosing a Salt Solution
77
Table F.1: Salt Solution Humidity Standards in Percent RH
77
Preparing a High Level Calibration Standard
78
Preparing a Low Level Calibration Standard
78
Preparing a Saturated Salt Solution
78
Appendix G: Permeant Sensor Adjustment
79
Permeant Sensor Performance Check
79
Performing a Permeant Sensor Adjustment
79
Permeant Sensor Adjustment Test Setup
80
Appendix H: Compliance
83
Advertisement
Advertisement
Related Products
Lauper Instruments LIPPKE 2000 SL
Lauper Instruments Categories
Test Equipment
Portable Generator
Measuring Instruments
Laboratory Equipment
More Lauper Instruments Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL