Sign In
Upload
Manuals
Brands
KYOWA Manuals
Measuring Instruments
CTRS-100A
KYOWA CTRS-100A Manuals
Manuals and User Guides for KYOWA CTRS-100A. We have
2
KYOWA CTRS-100A manuals available for free PDF download: Instruction Manual
KYOWA CTRS-100A Instruction Manual (255 pages)
Compact Recorder
Brand:
KYOWA
| Category:
Measuring Instruments
| Size: 9 MB
Table of Contents
Table of Contents
3
Standard Accessories
9
Optional Accessories
13
Safety Precautions
15
Precautions Regarding Wireless Communication
23
Limited Lifespan Parts and Preventive Maintenance
25
Equipment Renewal
25
Notations of the Instruction Manual
26
Product Overview
27
System Configuration
31
Controls and Indicators
32
Compact Recorder: CTRS-100A
32
Remote Control Unit: CTRS-RCU010A
36
Strain / Voltage Unit: CTRS-CDV010A
41
Voltage Unit: CTRS-CVPS010A
41
Thermocouple Unit: CTRS-CTA010A
42
Synchronization Unit: CTRS-SYNC010A
43
Battery Unit: CTRS-BATT010A
45
Wireless LAN Unit: CTRS-WLAN010A/011A/012A
48
CAN Unit: CTRS-CAG010A
49
CAN/GPS Unit: CTRS-CAG011A
51
Installation Method
53
Installation Procedure
53
Unit Connection
54
CTRS-100A Wiring Method
57
Power Connector
57
Remote Control Connector
61
USB Connector
61
External I/O Connector
62
Input Connector
63
CTRS-CDV010A Wiring Method
68
CTRS-CVPS010A Wiring Method
69
CTRS-CTA010A Wiring Method
73
Attaching and Removing the Temperature Measuring Adapter
73
Connection to Terminal Block
74
CTRS-SYNC010A Wiring Method
76
SYNC in Connector
76
SYNC out Connector
77
CTRS-CAG010A Wiring Method
78
CTRS-CAG011A Wiring Method
79
CTRS-BATT010A Wiring Method
80
Power Connector
80
Connecting to a PC
82
USB Connection
82
Wired LAN Connection
84
Wireless LAN Connection
92
Connections and Settings During Synchronous Operation
98
USB Connection
100
Wired LAN Connection
102
Wireless LAN Connection
104
Turning the Power on or off
107
Measurement
109
Types of Measurement
109
Online Measurement
109
Offline Measurement
112
Inserting or Removing an SD Card
114
Measurement Condition Settings
116
Common Settings
116
Analog Channel
123
External I/O
129
External Trigger Input
129
External Trigger Output
131
External Clock Input
139
External Clock Output
141
Remote Control Unit Settings
144
Wireless LAN Unit Setting
146
Wireless LAN Condition Setting
146
Initialization of SSID and Security Key
147
About DHCP Server Function
148
Thermocouple Unit Setting
149
Internal Sampling Frequency Setting
149
Reference Junction Compensation Setting
151
CAN Unit Setting
152
Comunication Condition Setting
152
Receiving Condition Setting
159
Number of Messages that Can be Received Per Second
163
CAN Output Setting
165
CAN/GPS Unit Setting
169
Point Zero (Manual) Setting
169
Point Zero (Manual N. of Data) Setting
171
Interval (GPS Sync) Setting
173
Installation of CTRS-100A
176
GPS Data Recording
177
About GPS Sensor Status
179
Recording Operation When GPS Status Is Not "OK
182
Other Functions
185
Data Protection Functions
185
File Closing Function
185
Data Protection Function During Power Interruption
186
Recording Resumption Function
188
Input Resistance Check Function (CTRS-100A, CTRS-CDV010A)
191
Burnout Check Function (CTRS-CTA010A)
193
Communication Speed Survey (CTRS-CAG010A)
195
Can Output Test (CTRS-CAG010A)
197
Time Correction Function (CTRS-CAG011A)
200
Utility Nuts
202
Utility Nut Positions
202
Size of Attachment Screws
204
Troubleshooting
207
CTRS-100A Details
207
CTRS-RCU010A Details
208
CTRS-CDV010A Details
209
CTRS-CVPS010A Details
210
CTRS-CTA010A Details
211
CTRS-SYNC010A Details
212
CTRS-BATT010A Details
213
CTRS-WLAN010A/011A/012A Details
214
CTRS-CAG010A Details
216
CTRS-CAG011A Details
218
Maintenance
221
Maintenance Details
221
Initializing the CTRS-100A
223
Product Specifications
225
CTRS-100A Product Specifications
225
CTRS-RCU010A Product Specifications
229
CTRS-CDV010A Product Specifications
230
CTRS-CVPS010A Product Specifications
232
CTRS-CTA010A Product Specifications
234
CTRS-SYNC010A Product Specifications
235
CTRS-BATT010A Product Specifications
236
CTRS-WLAN010A/011A/012A Product Specifications
238
CTRS-CAG010A Product Specifications
239
CTRS-CAG011A Product Specifications
240
External Views
243
CTRS-100A External Views
243
CTRS-RCU010A External Views
243
CTRS-CDV010A External Views
244
CTRS-CVPS010A External Views
244
CTRS-CTA010A External Views
245
CTRS-SYNC010A External Views
245
CTRS-BATT010A External Views
246
CTRS-WLAN010A/011A/012A External Views
246
CTRS-CAG010A External Views
247
CTRS-CAG011A External Views
247
Technical Information
249
Cable Calibration Value
249
Appendix
251
Special CTRS-RCU010A Operations
251
Estimated Operating Time When Using the Battery Unit
253
About the Size of the Recording File
254
Advertisement
KYOWA CTRS-100A Instruction Manual (95 pages)
Brand:
KYOWA
| Category:
Measuring Instruments
| Size: 1 MB
Table of Contents
Table of Contents
2
Folder Structure
6
Outline
8
Operating Environment
8
Functions
8
Limitations
8
Required Files
8
Excel VBA Sample Programs
9
Sample Programs
9
Required Files
9
Operating Environment
9
Preparation
9
Program to Control CTRS from a PC and Obtain Monitor Data
10
Outline
10
Operations
10
Measurement Conditions
10
Program Execution
11
Program to Convert a KS3 File on an SD Card into CSV Format
14
Outline
14
Operations
14
Program Execution
15
Common Function Specifications
19
Functions Return Values
19
CTRS Status
20
CTRS Error Statuses
27
List of Control Functions
31
Processes When Connected to CTRS
31
Functions for Sending/Receiving Control Commands to CTRS
31
Functions Related to Setting/Loading DLL Internal Parameters
32
General-Purpose Functions
33
Function Execution Availability
34
Descriptions of Functions
36
Processes When Connected to CTRS
36
Start CTRS Control
36
Check CTRS Connection Status
36
End CTRS Control
36
Functions for Sending/Receiving Control Commands to CTRS
37
Set Data File Name
37
Load Data File Name
37
Set Monitor Data Output Conditions
38
Load Monitor Data Output Conditions
40
Save Measurement Conditions Set in CTRS to SD Card
41
Load Measurement Conditions Saved to SD Card and Set Conditions in CTRS
41
Set Measurement Conditions
42
Load Measurement Conditions
43
Initialize Measurement Conditions (Parameters) Set in CTRS
43
Start AD Conversion and Switch to Monitor Status
44
Start Data Recording
45
Stop AD Conversion or Data Recording
45
Pause Recording in Manual Measurement Mode (Pause Status)
45
Clear Range-Over Status Occurring During AD
46
Execute Measurement Channel Check
46
Obtain Measurement Channel Check Result
47
Obtain Monitor Data (AD Value)
48
Obtain Monitor Data (Range Value)
49
Insert Marker into Record File
51
Load Marker from Record File
51
Lock Remote Control Unit Buttons
52
Load Remote Control Unit Button Lock Status
52
Set Date and Time
53
Load Date and Time Setting
53
Load CTRS System Information
54
Flash or Light up LED
54
Check Free Space on SD Card
55
Open Loaded File
55
Load Data from File Opened Via FOF Command
56
Close File Opened Via FOF Command
56
Delete File
57
Quick Format SD Card
57
Start Searching Files in Data Folder on SD Card
58
Continue File Search Started by Ctrs100_Fff
60
End File Search Started by Ctrs100_Fff Function
60
Delete Immediately Preceding Recorded Data File
61
Measure Measurement Channel of Measuring Unit with 1 Khz Sampling Frequency
61
Obtain the Result of Measuring with Ctrs100_Avg1
61
Execute Auto Range
62
Load Result of Ctrs100_Atr1
62
Load CTRS Status
63
Setting/Loading DLL Internal Parameters
64
Load System Information
64
Configure KS3 File-Related Settings
65
Configure Measurement Condition Settings
66
Load Measurement Condition Settings
69
Set Measurement Mode
72
Load Measurement Mode
73
Set Manual Measurement Conditions
74
Load Manual Measurement Conditions
75
Set Interval Measurement Conditions
76
Load Interval Measurement Conditions
77
Set Trigger Overall Conditions
78
Load Trigger Overall Conditions
79
Set Analog Trigger Conditions
80
Load Analog Trigger Conditions
81
Set External Trigger Conditions
82
Load External Trigger Conditions
82
Set Compound Trigger Conditions
83
Load Compound Trigger Conditions
84
Set Marker Name
85
Load Marker Name Settings
85
Set Test Information
85
Load Test Information
86
Set Channel Conditions
87
Load Channel Conditions
89
Set Offset Zero Conditions
90
Load Offset Zero Condition Settings
90
Set Channel Name
91
Load Channel Name
91
Set TEDS Information for Channel Conditions
91
Load TEDS Information for Channel Conditions
92
Set Rated Capacity, Etc
92
Load Rated Capacity, Etc. Settings
93
General-Purpose Functions
93
Collect Data File (KS3 File) from CTRS SD Card
93
Convert KS3 File on a PC into CSV File
94
Obtain Exedownloadfile and Execonvertks3Tocsv Progress
95
Stop Exedownloadfile and Execonvertks3Tocsv Operations
95
Advertisement
Related Products
KYOWA CVM-40A
KYOWA CDV-40B
KYOWA CDV-40B-F
KYOWA CDV-40A
KYOWA CDV-40A-F
KYOWA CVM-41A
KYOWA CDV-44AS
KYOWA CDV-900A
KYOWA CAN-40A
KYOWA CDA-45AS
KYOWA Categories
Transducer
Measuring Instruments
Rice Cooker
Amplifier
Kitchen Appliances
More KYOWA Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL