Sign In
Upload
Manuals
Brands
Kongsberg Manuals
Fish Finder
Simrad MF90
Kongsberg Simrad MF90 Manuals
Manuals and User Guides for Kongsberg Simrad MF90. We have
1
Kongsberg Simrad MF90 manual available for free PDF download: Installation Manual
Kongsberg Simrad MF90 Installation Manual (426 pages)
Fish-finding sonar
Brand:
Kongsberg
| Category:
Fish Finder
| Size: 8.14 MB
Table of Contents
Table of Contents
5
About this Manual
13
Simrad Mf90
15
Important
16
System Description
18
System Diagram
20
System Units
22
Display Description
22
Processor Unit Description
23
Transceiver Unit Description
24
Hull Unit Description
25
Transducer Description
27
Installation Trunk Description
28
Additional Required and Optional Items
30
Installation Trunk Requirement
30
Speed Log Requirement
31
Course Gyro Requirement
31
Uninterruptible Power Supply (UPS) Requirement
32
Operating Panel Option
32
Global Positioning System (GPS) Option
33
Scope of Supply
34
General Safety Rules
35
Installation Requirements
37
Supply Voltage Requirements
37
Uninterruptible Power Supply (UPS) Requirements
37
Cables and Wiring Requirements
38
Compass Deviation Requirements
39
Noise Sources
39
Dry Docking Requirements
40
Requirement for Classification Approval
40
Network Security
40
Support Information
41
Preparations
44
Installation Summary
45
General Safety Rules
48
About Installation Drawings
49
Tools, Equipment and Consumables Required for Installation
50
Personnel Qualifications
50
Rules for Transducer Handling
51
Choosing the Best Location for the Hull Unit
53
About the Hull Unit Location
53
Defining the Fore and Aft Location of the Hull Unit
54
Defining the Athwartships Location of the Hull Unit
55
Installation with more than One Hull Unit
55
Installation Close to Echo Sounder Transducer(S)
56
Important Considerations Related to Noise
57
Location of Hardware Units on the Bridge
58
Basic Requirements for the Location of Bridge Units
58
Maximum Distance between each Bridge Unit
59
Choosing the Best Location for the Display
61
Choosing the Best Location for the Processor Unit
61
Choosing the Best Location for the Operating Panel
62
Sonar Room Requirements
64
About the Sonar Room
64
Environmental Requirements
64
Requirements for Watertight Integrity
65
Size and Access Requirements
66
Requirements for Insulation, Heating and Ventilation
67
Requirements for Electrical Installations, Cables and Communication
68
Requirements for Bilge Pump and Decking
69
Lifting Requirements
69
Acoustic Noise
70
Introduction to the Acoustic Noise Challenge
70
Contributing Factors
70
Self Noise
72
Ambient Noise
75
Electrical Self Noise
75
Reverberation
76
Some Means to Reduce Acoustic Noise
77
Mounting the Installation Trunk
80
About the Installation Trunk
81
O-Ring/Rubber Gasket
82
Mechanical Support of the Installation Trunk
83
Design and Installation Drawings
85
MF90 Installation Example (on Keel)
86
MF90 Installation Example (off Keel/Without Blister)
87
MF90 Installation Example (off Keel/With Blister)
89
MF94 Installation Example (on Keel)
90
MF94 Installation Example (off Keel/Without Blister)
91
MF94 Installation Example (off Keel/With Blister)
92
Mounting the Installation Trunk Adapter
94
Mounting the Installation Trunk
95
Verifying the Quality of the Installation
98
Installing the Hull Unit
101
About the Hull Unit Installation
102
Mechanical Support of the Hull Unit Gantry
103
O-Ring/Rubber Gasket
104
Design and Installation Drawings
105
Hull Unit Installation Example: Top View
106
Hull Unit Installation Example: Side View (on Keel)
108
Hull Unit Installation Example: Side View (off Keel/Without Blister)
109
Hull Unit Installation Example: Side View (off Keel/With Blister)
110
Hull Unit Familiarization (MF90)
111
Hull Unit Familiarization (MF94)
112
Unpacking the Hull Unit from Its Transport Box
113
Mounting the Hull Unit on Top of the Installation Trunk (MF90)
115
Mounting the Hull Unit on Top of the Installation Trunk (MF94)
118
Designing and Mounting Mechanical Support Brackets to Secure the Hull Unit
121
Hull Unit and Transducer Alignment
124
Inspecting the Transducer
124
Verifying the Quality of the Hull Unit Installation
125
Installing the Mf90 System Hardware Units
128
General Safety Rules
129
Installing the Display
131
Installing the HT20470 Processor Unit
132
Installing the Operating Panel (Mk2)
135
Installing the Operating Panel (Mk3)
137
Installing the Transceiver Unit
139
Location of the Mounting Brackets
142
Installation of the Mounting Brackets
143
Connecting the Transceiver Unit to Vessel Ground
144
Cable Layout and Interconnections
145
Read this First
146
Cable Plans
147
Topside Cable Plan
148
List of Topside Cables
150
Sonar Room Cable Plan
152
List of Sonar Room Cables
153
Comments
153
Options
155
Installing the MF90 Cables
156
Prerequisites for Cable Installation
157
Installing the Topside Cables
157
Installing the Sonar Room Cables
159
Processor Unit Rear Panel Description: HT20470 (DC Version)
161
Operating Panel Connectors (Mk2)
164
Operating Panel Connectors (Mk3)
165
Cable Drawings and Specifications
166
RS-232 Serial Line Connection Using Three Wires
167
RS-232 Serial Line Connection Using Five Wires
168
Used as Synchronization Trigger (Input or Output)
169
RS-422 Serial Line Connection Using Five Wires
170
Moxa CP114EL-I Serial Line Adapter
171
Powered Audio Output
173
Power Supply Connectors
174
RJ45 High Speed Ethernet Cable (from Computer to Transceiver)
175
Ethernet Cable from Transceiver Unit to Motor Control Unit
177
AC Mains Power Cable (3-Phase) to the Motor Control Unit
178
Emergency Hoist Connections
179
Connection between the Gate Valve and the Motor Control Unit
181
RJ45 High Speed Ethernet Cable (1000Base-T)
183
K-Sync Interface to Generic RS-232 Synchronization Input
184
Simrad TU40 Interface to Generic RS-232 Synchronization Input
186
Setting to Work
188
Setting to Work Summary
189
Inspecting the Installation of the MF90 System
191
Visual Inspection of the Display
191
Visual Inspection of the Processor Unit
193
Visual Inspection of the Operating Panel
195
Visual Inspection of the Transceiver Unit
196
Visual Inspection of the Hull Unit
198
Checking the Environmental Conditions in the Sonar Room
200
Making Sure that All MF90 System Cables Are Properly Connected
201
Starting up the Hull Unit
203
Hull Unit Description
203
Hull Unit Familiarization (MF90)
206
Hull Unit Familiarization (MF94)
207
Motor Control Unit Familiarization
208
Initial Safety Check of the Motor Control Unit
209
Checking the Hosting Motor's 3-Phase AC Connections
210
Connecting the 3-Phase AC Power to the Motor Control Unit
212
Venting the Transducer Shaft Sleeve
213
Checking the 3-Phase Connection for Correct Rotation
214
Checking the Operation of the Hoisting and Lowering Contactors
216
Checking the Transducer Lowering and Hoisting Functionality
218
Initial Start-Up
221
Summary of Initial Start-Up
221
Making Sure that the Operating Power Is Correct
222
Making Sure that the Transducer Cannot be Accidentally Lowered
224
Connecting the Transducer Cables to the Transceiver Unit
225
Finalizing the Cable Connections
226
Installing the Operating Software
226
Obtaining and Installing a Software License for Additional Functionality
228
Selecting Hull Unit
230
Defining the Middle Position of the Transducer
231
Configuring the Operating Panel (Mk2)
233
Setting up the Operating Panel (Mk2)
233
Using more than One Operating Panel to Control the Sonar (Mk2)
237
Using a Single Operating Panel to Control more than One Sonar (Mk2)
241
Turning on the MF90 System for the First Time
245
Turning on the Entire System: Introduction
245
Turning on the Entire System: Preparations
246
Turning on the Entire System: Bridge Steps
247
Turning on the Entire System: Sonar Room Steps
249
Turning on the MF90 System for Normal Use
251
Placing each Sensor in the Vessel Coordinate System
253
Dimensional Surveying
253
Surveying the Transducer and the Navigation Sensors
255
Example Procedure
256
Vessel Coordinate System
258
Inserting the Installation Parameters
261
Correct Installation Parameters Are Crucial for Sonar Operation
261
Inserting the Ship Origin and Dimensions
262
Inserting the Installation Parameters for the Transducer
265
Inserting the Installation Parameters for the Motion Reference Unit (MRU)
268
Adjusting the Built-In Motion Sensor Offset
271
Adjusting the Stabilization Offsets for the External Motion Sensor
274
Setting up the Interfaces to Peripheral Devices
278
Installing Navigation Sensors and Other Sensors
278
Defining the Serial and Ethernet (LAN) Port Parameters
279
Setting up the Input from a Navigation System (GPS)
281
Setting up the Interface for Speed Log Input
284
Setting up the Interface for Course Gyro Input
286
Configuring the Sensor Interface
289
Setting up the Input from a Motion Reference Unit (MRU)
291
Setting up the MF90 System for Synchronized Operation
293
Setting up Input from Buoys, Fish Aggregating Devices and Other External Objects
296
Configuring the MF90 System for Normal Operation
299
Selecting Measurement Units
299
Setting up the Alarm Limits for System Protection
300
Configuring the MF90 System for Data Recording
302
Configuring the Environmental Parameters
304
Selecting the Language Displayed in the Menus and Dialog Boxes
305
Saving the Current User Settings
305
Defining the User-Selected Features on the Operating Panel
307
Selecting Which Operating Panel to Use
307
Assigning User Settings or Presentation Modes to the Operating Panel
308
Assigning Functions to the Rotary Switches on the Operating Panel
310
Assigning Functions to F1, F2 and F3 on the Operating Panel (Mk2)
313
Testing the Operating Functionality of the MF90 System
316
Checking the Hull Unit Lowering and Hoisting Functionality
316
Verifying System Operation by Means of the Element BITE Functionality
321
Measuring the Noise in Passive Mode
325
Verifying System Operation by Means of the Diagnostics Functionality
327
Making a Noise/Speed Curve to Determine Vessel Noise
331
Creating a Backup with the MF90 Configuration and Software Installation
335
About MF90 Software Backup and Restore
335
Creating a Backup Image Using the Desktop Application
336
Creating a Backup Image Using the Boot Application
338
Restoring from a Backup Image Using the Desktop Application
340
Restoring from a Backup Image Using the Boot Application
342
Creating a Bootable USB Flash Drive
345
Installation Remarks
347
Technical Specifications
348
Introduction to Technical Specifications
349
Performance Specifications
349
Power Requirements
354
Display Power Requirements
354
Operating Panel Power Requirements (Mk2)
354
Operating Panel Power Requirements (Mk3)
355
Transceiver Unit Power Requirements
355
Hull Unit Power Requirements
355
Weights and Outline Dimensions
357
Display Weight and Outline Dimensions
357
Operating Panel Weight and Outline Dimensions (Mk2)
357
Operating Panel Weight and Outline Dimensions (Mk3)
358
Transceiver Unit Weight and Outline Dimensions
358
Hull Unit Weight and Outline Dimensions
358
Environmental Requirements
360
Display Environmental Requirements
360
Operating Panel Environmental Requirements (Mk2)
360
Operating Panel Environmental Requirements (Mk3)
361
Transceiver Unit Environmental Requirements
361
Hull Unit Environmental Requirements
361
Compass Safe Distance
363
Display Compass Safe Distance
363
Operating Panel Compass Safe Distance (Mk2)
363
Operating Panel Compass Safe Distance (Mk3)
363
Transceiver Unit Compass Safe Distance
364
Hull Unit Compass Safe Distance
364
Minimum Display Requirements
364
Drawing File
366
About the Drawings in the Drawing File
367
494024 Processor Unit Outline Dimensions (HT20470/DC)
368
494025 Processor Unit Outline Dimensions (HT20470/AC)
371
493234 Transceiver Dimensions
374
443179 Operating Panel Dimensions (Mk2)
377
440689 Operating Panel Cut-Out Drawing (Mk2)
380
439594 Operating Panel Adapter Plate (Mk2)
381
476352 Operating Panel Dimensions (Mk3)
383
489166 Hull Unit Dimensions MF90
386
489167 Hull Unit Dimensions MF94
389
402509 Installation Trunk Dimensions
392
427176 Installation Trunk Dimensions
395
434524 Installation Trunk Dimensions
397
051344 Blind Flange Dimensions (Ø370 MM)
400
207485 Blind Flange Dimensions (Ø760 MM)
401
General Safety Rules
402
Datagram Formats
404
Advertisement
Advertisement
Related Products
Kongsberg MS1000
Kongsberg ME70BO
Kongsberg MS1000 2U
Kongsberg MBR 144
Kongsberg M3 Sonar PHS
Kongsberg M3 Sonar FLS
Kongsberg M3 Sonar API
Kongsberg MPT 3 Series
Kongsberg cNODE Maxi 31 Ex d
Kongsberg M3 Bathy
Kongsberg Categories
Marine Equipment
Sonar
Marine Radio
Transceiver
Radio
More Kongsberg Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL