KMC Controls SimplyVAV BAC-8205 Manuals
Manuals and User Guides for KMC Controls SimplyVAV BAC-8205. We have
2
KMC Controls SimplyVAV BAC-8205 manuals available for free PDF download: Application And Installation Manual, Quick Start Manual For Installing
KMC Controls SimplyVAV BAC-8205 Application And Installation Manual (75 pages)
Brand:
KMC Controls
| Category:
Controller
| Size: 6 MB
Table of Contents
Table of Contents
3
Contents
3
Section 1: about the Controllers
6
Specifications
6
Accessories and Replacement Parts
9
Available Models
10
Safety Considerations
10
Section 2: Installing the Controllers
13
Setting the Rotation Limits
13
Mounting on a VAV Terminal Box
14
Connecting an Airflow Sensor
15
Connecting Inputs and Outputs
15
Connecting Room Temperature Sensors
15
Connecting a DAT Sensor
16
Connecting Power
17
Maintenance
18
Section 3: Changing the Room Setpoint
19
Section 4: Configuring the Controllers
21
Getting Started with Configuration
21
Entering System Temperature Setpoints and Limits
23
Setpoint on Page
24
Configuring the VAV Box Options
27
Set the Airflow Setpoints
29
Advanced Options
33
Restore Application
35
Section 5: Balancing Airflow
37
Section 6: Application Drawings
41
Cooling or Heating Without Reheat
42
Advanced Options on Page
42
Staged Reheat
43
Modulating Reheat
44
Time Proportional Reheat
45
Floating Reheat
46
Dual-Duct Application
47
Section 7: Sequences of Operation
49
Input Sources
49
Occupancy Sequence
50
Automatic Occupancy
50
Occupied
50
Unoccupied
51
Standby
51
Space Setpoints
51
Types of Setpoints
51
Setpoint Limits
52
PID Control Loops
52
Airflow Setpoints Sequence
53
Changeover
53
Discharge Air Temperature (DAT) Limiting
53
System Diagnostic Indicators
54
Need Ahu (Bv1)
55
Need Colder Supply (Bv2)
55
Need more Static (Bv3)
55
Need Hotter Supply (Bv7)
55
Damper Operation
55
Fan Operation
56
Series Fan
56
Parallel Fan
56
Reheat Sequence
57
Modulating Reheat
58
Staged Reheat
58
Time Proportioned Reheat
59
Floating Reheat
59
Balancing Airflow Sequence
60
Dual Duct
61
Section 8: System Integration and Networking
63
Connecting to an MS/TP Network
63
Connections and Wiring
64
End of Line Termination Switches
64
Network Bulbs
64
Setting up Network Communications
65
Bacnet Objects
67
Input Objects
67
Output Objects
67
Value Objects
68
Loop Objects
70
Appendix A: K-Factors
71
Index
73
Advertisement
KMC Controls SimplyVAV BAC-8205 Quick Start Manual For Installing (2 pages)
Brand:
KMC Controls
| Category:
Controller
| Size: 0 MB
Table of Contents
Align the Damper and Drive Hub
1
Mount the Controller to the VAV Box
1
Connect the Room Sensor Cable
1
Connect the Airflow Sensors
1
Connect Auxiliary Equipment (Optional)
1
Connect 24 Volt Power
1
Quick Start Configuration Guide for Simplyvav Controllers
2
To Get Started
2
CNFG the Main Configuration Parameters for the VAV Terminal Unit
2
COMM Set Bacnet Device Instance, MAC Address, and Network Baud
2
BLNC Set Airflow Balancing Parameters
2
STPT Enter Temperature Setpoints and Limits
2
BOX Set up Reheat, Fan Operation, and Basic Terminal Unit Functions
2
FLOW Set Airflow Setpoints and Limits
2
ADVC Enter Passwords and Enable Model Specific Features
2
RSTR Restore to Factory Settings
2
Advertisement
Related Products
KMC Controls SimplyVAV BAC-8001
KMC Controls SimplyVAV BAC-8005
KMC Controls SimplyVAV BAC-8007
KMC Controls SimplyVAV BAC-8201
KMC Controls BAC-4000 series
KMC Controls BAC-9001CE
KMC Controls BAC-9021
KMC Controls BAC-7302C
KMC Controls BAC-9311 VAV
KMC Controls BAC-9301 FCU 4-Pipe
KMC Controls Categories
Controller
Thermostat
Accessories
Farm Equipment
Temperature Controller
More KMC Controls Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL