Table of Contents
2
Description
6
Manual Structure
6
Novar1106/1114/1206/1214 Basic Functions
6
Novar Controller Version "/S400
7
Novar-1005 / 1007 / 1005D / 1007D
7
Novar1312, Novar1312-3, Novar1005T
7
Novar1414
8
History of Firmware Versions
8
Front Panel
9
Numeric Display
9
Novar 11Xx / 12Xx / 13Xx Controllers
9
Instantaneous Measurement Values
9
Main Branch
9
COS Branch
11
A Branch
12
Branch
13
Controller Parameters
14
Novar 10Xx Controllers
15
Test and Error Messages
15
Indication Leds
15
Output State Indications
16
Trend Indication
16
Indication of Manual Mode
16
Indication of Backfeed (Power Export)
16
Alarm Indication
16
Installation
17
Physical
17
Connection
17
Power Supply
17
Standard Version Controllers
17
S400" Version Controllers
18
Novar 1005 / 1007 Controllers
18
Novar 1005D / 1007D Controllers
19
Protection
19
Measurement Voltage
19
11Xx and 10Xx Line Controllers
19
12Xx Line Controllers
19
Measurement Current
20
Novar 11Xx / 12Xx / 13Xx Controllers
20
Novar 10Xx Controllers
20
Error Indication
20
Output Relays
20
Standard Version Controllers
20
S400" Version Controllers
20
Novar 10Xx Controllers
21
Second Metering Rate, External Alarm
21
Communication Interface
21
RS-485 Communication Interface
21
Ethernet (IEEE802.3) Interface
22
Putting in Operation
23
First Use
23
Automatic Connection Configuration Detection Process
23
Automatic Section Power Recognition Process
24
Operation
27
Setup
27
Editing Parameters and Clearing Recorded Measurement Values
27
Parameter Editing
27
Clearing Recorded Measurement Values
27
Enable / Disable Parameter Edit
27
Parameter 01/07 - Target Power Factor
28
Parameter 02/08 - Undercompensation Control Time
28
Parameter 03/09 - Overcompensation Control Time
29
Parameter 04/10 - Control Bandwidth on High Loads
29
Parameter 05/11 - Offset Power
31
Parameter 06 - Metering Rate 2 Operation
32
Parameters 12,13 - Metering Current Transformer (CT) Ratio
32
Parameter 14 - Reconnection Delay Time
32
Parameters 15, 16 - Type of Measurement Voltage and Connection Configuration
33
Setting Type of Connection Configuration if Measuring at Power Supply Transformer's Opposite Sides
34
Parameter 17 - Metering Voltage Transformer (VT) Turns Ratio
35
Parameter 18 - Compensation System Nominal Voltage (UNOM )
35
Parameter 20 - Automatic Section Power Recognition Process
35
Parameter 21, 22 - Switching Program, Selection of Linear Switching Mode and Smallest
36
Min
36
Parameter 23 - Number of Capacitors
37
Parameter 25 - Compensation Section Nominal Power
37
Parameter 26 - Fixed Sections, Switching Cooling and Heating, Alarm
38
Fixed Sections
38
Switching Cooling and Heating
39
Alarm Signalling ( Novar 10Xx Only )
39
Parameter 27 - Limit Power Factor for Compensation by Choke
39
Parameter 30 - Alarm Setting
39
Alarm Indication
41
Alarm Actuation
41
Parameters 31 through 37 - Alarm Indication/Actuation Limits
42
Parameter 40 - Alarm Status
43
Parameters 43, 44 - Total Section Connection Time and Number of Section Switching Operations
43
Parameter 45 - Type of Controller Error
43
Parameter 46 - Control Time
43
Parameter 55 - Power System Frequency
44
Parameters 56, 57 - Average, Maximum, Minimum Value Evaluation Window Size
44
Parameter 58 - Temperature Display °C / °F
45
Parameters 59, 60 - Cooling and Heating Switching Thresholds
45
Parameter 63 - Offset Control
45
Section Value Accurization
46
Faulty Section Indication and Disablement
47
Compensation by Choke
47
Basic Choke Compensation
48
Symmetric Choke Compensation
48
Control Interruption
49
Manual Mode
49
Manual Intervention in Control Process
49
Controller Initialization
50
Capacitor Harmonic Load Factor (CHL)
50
Text Messages
53
Novar1312, Novar1312-3, Novar1005T Description
54
Basic Operation
54
Novar1312
54
Novar1312-3
54
Novar1005T
54
History of Firmware Versions
55
Installation
55
Measurement Currents
55
Novar1312
55
Novar1312-3
55
Novar1005T
55
Transistor Outputs
55
Novar-1312, Novar-1312-3
55
Novar-1005T
56
Relay Outputs
57
Communication
57
Operation
57
Thyristor and Contactor Group
57
Control Principles
57
Setup
58
Parameter 28 - Number of Capacitors in Thyristor Group
58
Parameter 29 - Thyristor Group Control Rate and Reconnection Delay Time
58
Control Operation at the Highest Control Rate
59
Novar-1414 Description
62
Basic Operation
62
Measurement Values
62
Main Branch
62
COS Branch
62
A Branch
63
Branch
63
Installation
63
Measurement Currents
63
Communication
64
Setup
64
Parameter 16 - Method of Connection of U and I
64
Wiring Examples
66
Technical Specifications
78
Maintenance, Troubleshooting
80
Advertisement
Advertisement
Related Products
KMB NOVAR-1005
KMB NOVAR-1007
KMB NOVAR-1005D
KMB NOVAR-1007D
KMB NOVAR-1106
KMB NOVAR-1114
KMB NOVAR-1206
KMB NOVAR-1214
KMB NOVAR-1414
KMB NOVAR-1 Series
KMB Categories
Measuring Instruments
Controller
Dehumidifier
Power Supply
Control Unit
More KMB Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL