Sign In
Upload
Manuals
Brands
Keysight Technologies Manuals
Measuring Instruments
53200 Series
Keysight Technologies 53200 Series Manuals
Manuals and User Guides for Keysight Technologies 53200 Series. We have
1
Keysight Technologies 53200 Series manual available for free PDF download: Service Manual
Keysight Technologies 53200 Series Service Manual (274 pages)
Brand:
Keysight Technologies
| Category:
Measuring Instruments
| Size: 9 MB
Table of Contents
Safety Information
5
Protection Limits
6
Table of Contents
7
Chapter 1 Performance Tests
13
Introduction
14
Chapter Overview
15
Power-On Test
15
Operational Verification
15
Performance Test Record
16
Test Considerations
16
Recommended Calibration Cycle
17
Internal Auto-Calibration
17
Equipment Required
18
Power-On Test
19
Self-Test (Q)
21
Run Internal Self-Test
21
Keysight 53210A/53220A/53230A Operational Verification
23
Frequency Checks
23
Termination Checks (Optional)
25
Keysight 53210A/53220A/53230A Complete Performance Tests
27
Test 1: (Q) Absolute Time Base
29
Counter Setup
29
Test 2: (Q) Frequency Accuracy - Channels 1 and 2
33
Test 3: Single Period
41
Test 4: (Q) Pulse Width
47
Test 5: (Q) Time Interval
53
Test 6A: (Q) Frequency Accuracy - Channel 2/3, Option 106 (6 Ghz Microwave Channel)
59
Test 6B: (Q) Frequency Accuracy - Channel 2/3, Option 115 (15 Ghz Microwave Channel)
65
Test 7A: (Q) Pulse Burst Frequency - 53230A Channel 3 Option
71
With Option 106
71
Test 7C: (Q) Pulse Burst Frequency - 53230A Channel 3 Option
71
With Option 115
77
Keysight 53210A/53220A/53230A Operational Verification and Performance Test Record
84
Keysight 53210A/53220A/53230A Performance Test Record (Tests 1 to 7)
85
Chapter 2 Service
95
Introduction
96
Returning the Counter to Keysight Technologies for Service
96
About the Keysight 53210A/53220A/53230A Calibration Menu
96
The Keysight 53210A/53220A/53230A Calibration Procedures
96
Pre-Troubleshooting Information
96
Troubleshooting Information
96
Returning the Instrument to Keysight Technologies for Service
100
Operating Checklist
100
Is the Instrument Inoperative
100
Does the Instrument Fail Self-Test
100
Types of Service Available
100
Extended Service Contracts
100
Obtaining Repair Service (Worldwide)
101
To Provide Repair Information
101
To Pack in the Original Packaging Materials
102
To Pack in Commercially Available Materials
103
Warranty
103
About the Keysight 53210A/53220A/53230A Calibration Menu
104
Overview of the Keysight 53210A/53220A/53230A Calibration Menu
104
To Get Help with the Calibration Menu Functions
106
To View the Calibration Menu and Security Status from the Counter Front Panel
108
To Lock the Counter against Calibration
109
To Unlock the Counter for Calibration
111
To Change to a New Security Code
112
The Keysight 53210A/53220A/53230A Calibration Procedures
113
Equipment Required
113
Determine the Counter Firmware Version
114
Calibration Cycle
116
Calibration String
116
Internal Reference Oscillator Calibration
116
Summary of Oscillator Calibration Procedure
121
Remote Oscillator Calibration Summary
121
Voltage Calibration (Internal Dacs)
122
Option 106 Microwave Channel Frequency Calibration
128
Option 115 Microwave Channel Frequency Calibration
136
Internal Auto-Calibration
144
To View the Calibration Count
147
Resetting the Security Code to a Null
149
Pre-Troubleshooting Information
150
Safety Considerations
150
Recommended Test Equipment
151
Repair Considerations
152
Electrostatic Discharge
152
Surface Mount Repair
152
After Service Considerations
153
Troubleshooting the Counter
158
Unit Is Inoperative
158
Unit Fails Self-Test
158
Power Supply Check
158
Checking the Battery and Battery Charger
162
Battery Operation
162
Preliminary Steps
162
Testing the Battery
164
Performing the Counter Self-Test
168
To Determine the Counter Firmware Version
169
Reseat the Boards
171
Re-Run the Counter Self Test
171
Error Messages
172
Command Errors (-100
172
Execution Errors (-200
172
Hardware Errors (-240, -241, -250
173
Device-Specific Errors (-300
174
Query Errors (-400
175
Calibration Errors (700
175
Self-Test Errors (901
176
Diagnosing the Faulty Assembly Using Self Test Errors
176
Chapter 3 Replacing Assemblies
179
Introduction
180
Tools Required
181
Do this First
181
Electrostatic Discharge
182
To Remove the Cover and Rear Bezel
183
To Remove the Internal DC Battery Assembly (Option 300)
185
To Remove the GPIB Assembly
187
To Remove a 6.0 Ghz or 15.0 Ghz Microwave Channel Assembly (Options 106/115)
188
Re-Installing the Microwave Channel Assembly
189
To Remove the Processor Board
191
To Remove the Front Panel Assembly
192
To Remove the Display Assembly from the Front Panel
195
To Remove the Motherboard
196
To Remove the AC Power Supply Assembly
197
Chapter 4 Retrofitting Options
199
Introduction
200
Tools Required
200
Do this First
201
To Retrofit Ultra-High Stability Timebase (Option 010)
203
To Retrofit the GPIB Connector
204
GPIB Connector Parts (P/N 53200U-400)
204
Preliminary Steps
204
GPIB Connector Installation Procedure
205
Chapter 4 Retrofitting Options to Retrofit the Internal Battery DC Power (Option 300)
206
To Retrofit the Internal Battery DC Power (Option 300)
206
Option 300 DC Power Input Assembly Parts
206
Preliminary Steps
206
Battery Assembly Installation Procedure
207
To Retrofit the 53210A (Channel 1) or 53220A/53230A (Channels 1/2) Rear Panel Inputs (Option 201)
212
Option 201 Rear Panel Channel 1/2 Parts
212
Preliminary Steps
212
Channels 1/2 Rear Panel Retrofit Procedure
214
To Retrofit the 53210A Channel 2 Front Panel Input
216
Option 115, Plus Front Panel Option 202)
216
Option 106/115 Channel 2 Parts
216
Option 202 Front Panel Channel 2 Parts
216
Preliminary Steps
217
Channel 2 Front Panel Retrofit Procedure (53210A)
219
Or 15.0 Ghz (Option 115) Plus Rear Panel Option 203
226
Option 106/115 Channel 2 Parts
226
Option 203 Rear Panel Channel 2 Parts
226
Preliminary Steps
227
Channel 2 Rear Panel Retrofit Procedure (53210A)
229
Option 202 Front Panel Channel 3 Parts
231
Preliminary Steps
232
Front Panel Installation Procedure (Option 202 Only)
234
Option 203 Rear Panel Channel 3 Parts
242
Preliminary Steps
243
Rear Panel Installation Procedure (Option 203 Only)
245
To Retrofit Option 150 (Pulse Microwave Measurements) for the 53230A
247
Retrofitting Procedure
247
Chapter 5 Replaceable Parts
249
Introduction
250
Contacting Keysight Technologies
251
By Telephone (in the United States)
251
For Mail Correspondence, Use the Address below
251
How to Order a Part
252
Parts Identification
252
Replaceable Parts
254
Power Supply
256
Front Panel
257
Processor Board
257
Chapter 6 Backdating
259
Introduction
260
Serial Numbers
260
Backdating Firmware
262
To Determine the Counter Firmware Version
262
Installed Options
262
Procedure Changes
264
Information Concerning Option 106 "Microwave Input", FW Rev (27.0)
264
Option 106 Microwave Channel Frequency Calibration
264
Backdating Hardware
271
Backdating Specifications
272
Advertisement
Advertisement
Related Products
Keysight Technologies 53147A
Keysight Technologies 53149A
Keysight Technologies 53148A
Keysight Technologies 5061B
Keysight Technologies Option 503
Keysight Technologies Option 508
Keysight Technologies Option 513
Keysight Technologies Option 543
Keysight Technologies Option 544
Keysight Technologies Option 550
Keysight Technologies Categories
Measuring Instruments
Test Equipment
Control Unit
Portable Generator
Power Supply
More Keysight Technologies Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL