Table of Contents
Table of Contents
2
1 Introduction
4
2 Safety and Mounting
5
Safety
5
Mounting
6
3 Technical Specification
7
4 Control Panel Fascia
10
5 Connecting to the Circuit Board
12
6 Detection Zone Wiring
13
7 Sounder Circuit Wiring
13
8 Using Intrinsically Safe Barriers
14
9 Connection to Monitored Inputs
15
10 Connection to Extinguishant Output
15
Solenoid Wiring
15
Igniting Actuator Wiring
16
Setting up Extinguishant Monitoring Circuit
16
Adjustment
16
For 3 or more Actuators
17
For 1 or 2 Actuators
17
11 Connection to Remote Control Terminals
18
12 Aux 24V DC Supply
18
13 Connection to Relay Contacts
19
Fault Relay
19
Local Fire Relay
19
Fire Relay
19
St Stage Alarm
19
Nd Stage Alarm
19
Extract Relay
19
14 Connection and Configuration of Status Units and Ancillary Boards
20
Adding New Status Units/Ancillary Boards
20
Removing Status Units/Ancillary Boards
21
15 Panel Operation
21
Normal Condition
21
Single Zone Fire Condition
21
Double Zone Fire Condition
22
Manual Release
22
Silence/Sound Alarms
22
Reset
22
Zone Fault
22
Sounder Fault
22
Power Fault
22
System Fault
23
General Fault
23
Lamp Test
23
Hold Condition
23
Released Condition
23
Low Pressure Switch
23
Test Mode
23
Change Mode
24
Extract Fan
24
Disablements
24
Disable Zones
24
Disable Sounders
24
Activate Delays
24
Disable Fault Contact
24
Disable Extinguishant Subsystem
24
Disable 1 St Stage Contact
24
Nd Stage Contact
24
Disable Manual Release
25
Disable Extract Fan
25
16 Access Level 2 Configuration Options
25
T1 - 3] Test Zone
25
D1 - 3] Disable Zone
25
Db] Disable First Stage Sounders
25
Dp] Disable (Pre-Activated) First Stage Relay Contact
26
Da] Disable (Activated) Second Stage Relay Contact
26
DC] Disable Extract Fan Relay
26
Dt] Disable Manual Triggering Device (Manual Release)
26
De] Disable Extinguishant Release
26
Ad] Activate Delays
26
Ac] Operate Extract Fan Output
26
17 Access Level 3 Configuration Options
27
18 Internal Controls
30
Watchdog Reset
30
Processor Reset
30
Terminate Extinguishant
30
Commissioning
30
19 Internal Indications - Troubleshooting
31
Mains Fail
31
Batt Fail
31
CPU Fault
31
Aux 24V Fault
31
Batt Low
31
Comms Fault
31
Earth Fault
32
Sys Fuse Fault
32
S1, S2 and S3 Fault
32
Exting Fault
32
Hold Fault
32
Manual Release Fault
32
Mode Fault
32
Release Fault
32
Low Pres Fault
32
Tell Tale
33
20 Power Supply
34
21 Maintenance
35
22 Record of Configuration
35
23 CE Mark
39
24 Commissioning Instructions
40
Advertisement
Advertisement
Related Products
Kentec Electronics Sigma XT K11031F2
Kentec Electronics K921000M8
Kentec Electronics K921010M8
Kentec Electronics K921100M8
Kentec Electronics K921110M8
Kentec Electronics K921113M8
Kentec Electronics Sigma XT+
Kentec Electronics K1885
Kentec Electronics K1885-00
Kentec Electronics K1885-12
Kentec Electronics Categories
Control Panel
Control Unit
Fire Alarms
Measuring Instruments
Power Supply
More Kentec Electronics Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL