User Manuals: Keeler D-KAT Z Applanation Tonometer
Manuals and User Guides for Keeler D-KAT Z Applanation Tonometer. We have
1
Keeler D-KAT Z Applanation Tonometer manual available for free PDF download: Instructions For Use Manual
Keeler D-KAT Z Instructions For Use Manual (56 pages)
Digital Applanation Tonometer
Brand:
Keeler
| Category:
Measuring Instruments
| Size: 4 MB
Table of Contents
English
5
Table of Contents
5
How the Intraocular Pressure (Iop) Is Measured
8
Indications for Use
8
Intended Use / Purpose of Instrument
8
Brief Description of the Instrument
8
Advantages of Using a Goldmann Type Tonometer
9
Safety
9
Warnings and Cautions
9
Contraindication
11
Cleaning Tonometer Body
11
Cleaning and Disinfection Instructions
11
Disinfecting the Tonometer Prisms
12
Tonometer Prism Field Check
13
Name of Components
14
Switching on / off and Configuring the D-Kat
14
Switching on / off
14
Changing Decimal Point Setting
14
Measurement Procedure
15
Installation on to the Slit Lamp
15
Battery Status
15
Changing the Display Brightness
15
Preparing the Patient
16
Preparing the Slit Lamp Instrument for Examinations at 10X Magnification
17
Using the Instrument / Taking a Measurement
18
Problem Solving
19
The Fluorescein Ring Is too Wide or too Narrow
19
The Measurement Prism Does Not Touch the Cornea or too Much Force Has Been Applied
20
The Two Semicircles Are Not Central in the Field of Vision
20
The Inside Margins of the Fluorescein Rings Are Not Aligned and Touching
21
General Information and Suggestions Concerning Measurement
22
Astigmatism
23
Routine Instrument Maintenance
23
Check Procedure with Test Arm Set to 20
24
Routine Instrument Maintenance
25
Check Procedure with Test Arm Set to 20
25
Check Procedure with Test Arm Set to 60
25
Servicing and Calibration
26
Battery Replacement
26
Warranty
27
Technical Specifications
27
Accessories and Spares
28
Packaging and Disposal Information
29
Dansk
30
Indikationer for Brug
33
Kort Beskrivelse Af Instrumentet
33
Sådan Måles Det Intraokulære Tryk (Iop)
33
Tilsigtet Anvendelse/Instrumentets Formål
33
Advarsler Og Forsigtighedsregler
34
Fordele Ved Anvendelsen Af Tomometeret Af Goldmann-Typen
34
Sikkerhed
34
Anvisninger Til Rengøring Og Desinfektion
36
Kontraindikation
36
Rengøring Af Tonometerets Hoveddel
36
Desinfektion Af Tonometerets Prismer
37
Eftersyn Af Tonometerets Prismefelt
38
Komponenternes Navne
39
Tænde/Slukke
39
Tænde/Slukke Og Konfigurere D-Kat
39
Ændring Af Indstilling for Decimaler
39
Batteristatus
40
Installation På Spaltelampen
40
Målemetode
40
Ændring Af Skærmens Lysstyrke
40
Forberedelse Af Patienten
42
Klargøring Af Spaltelampeinstrumentet Til Undersøgelser Ved 10X Forstørrelse
42
Brug Af Instrumentet/Tage en Måling
43
Fluorescein-Ringen er for Bred Eller for Smal
44
Problemløsning
44
Måleprismet Rører Ikke Hornhinden, Eller der er Anvendt for Meget Kraft
45
To Halvcirkler er Ikke Placeret Centralt I Synsfeltet
45
Fluorescein-Ringenes Indvendige Marginer er Ikke På Linje Og Rører Hinanden
46
Generelle Oplysninger Og Forslag Til Måling
47
Astigmatisme
48
Rutinemæssig Vedligeholdelse Af Instrumentet
48
Gennemgå Proceduren Med Testarmen Indstillet Til 20
49
Gennemgang Af Proceduren Med Testarmen Indstillet Til 60
50
Gennemgå Proceduren Med Testarmen Indstillet Til 20
50
Rutinemæssig Vedligeholdelse Af Instrumentet
50
Service Og Kalibrering
51
Udskiftning Af Batteriet
51
Garanti
52
Tekniske Specifikationer
52
Tilbehør Og Reservedele
53
Information Om Emballage Og Bortskaffelse
54
Advertisement
Advertisement
Related Products
Keeler D-KAT
Keeler D-KAT R
Keeler D-KAT T
Keeler AccuPen
Keeler IntelliPuff
Keeler KAT
Keeler KAT R
Keeler KAT T
Keeler PachPen IFU-24-5100
Keeler Pulsair EasyEye
Keeler Categories
Measuring Instruments
Medical Equipment
Laboratory Equipment
Microscope
Headlamp
More Keeler Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL