Sign In
Upload
Manuals
Brands
Johnson Controls Manuals
Controller
HMS-2000
Johnson Controls HMS-2000 Manuals
Manuals and User Guides for Johnson Controls HMS-2000. We have
1
Johnson Controls HMS-2000 manual available for free PDF download: User Manual
Johnson Controls HMS-2000 User Manual (39 pages)
Fume Hood Controller
Brand:
Johnson Controls
| Category:
Controller
| Size: 2 MB
Table of Contents
Table of Contents
6
Introduction
8
Display Overview
8
Sensor Descriptions
11
Initial Setup
12
Configuration
12
Global Settings
12
Choosing a Unit of Measure
12
Choosing a Language
12
Turn Keyboard Clicks on or off
12
Adjusting the Screen Brightness
12
User Accounts
13
Admin User Capabilities
13
Restricted User Capabilities
13
User Name and Password Requirements
13
Creating the Admin User Account and Password
13
Creating a Restricted User and PIN
14
Deleting Users
14
Changing a User Name
14
Changing the Access Level of a Restricted User to an Admin User
14
Changing the Access Level of an Admin User to a Restricted User
14
Updating the PIN of a Restricted User
14
Forgotten Password or PIN
14
Network Setup
15
Setting up the Device ID
15
Setting up the Maxmaster
15
Choosing the Baud Rate
15
Setting the MAC Address for Bacnet MS/TP
15
Bacnet Objects
16
Analog Values
17
Analog I/O
19
Configuring Analog Inputs to Measure Pressure
20
Specifying the Parameter Type for Pressure
20
Specifying the Sensor Type
20
Specifying the Minimum Pressure Input
20
Specifying the Maximum Pressure Input
20
Specifying the K-Factor
21
Specifying the Sensor Location
21
Adjusting the Setpoint
21
Setting up the Analog Input Signal Range
21
Adjusting Deadband
21
Zero Calibration
22
Creating a Zero Offset
22
Resetting the Zero Offset
22
Setting the Alarms
22
Modifying the Default Alarm Limits
22
Configuring the Analog Input to Measure Air Flow
23
Specifying the Sensor Type to Measure Air Flow
23
Specifying the Maximum Input Setting to Measure Air Flow
23
Specifying the Minimum Input Setting to Measure Air Flow
23
Setting up the Duct Area to Measure Air Flow
24
Specifying the K-Factor to Measure Air Flow
24
Specifying the Output Signal Range for Air Flow
24
Adjusting Deadband for Air Flow
24
Enabling the Alarm and Changing the Alarm Limits for Air Flow
25
Naming the Air Flow Input
25
Digital Inputs
25
Configuring Digital Inputs for Occupancy Switch Mode
25
Configuring the Switch Type
25
Setting up a Delay
25
Configuring Digital Inputs for Flow Switch Mode
26
Configuring the Switch Type
26
Setting up a Delay
26
Relays
26
Configuring the Trigger Mode for Setpoint
26
Configuring the Input Channel
26
Configuring the High and Low Setpoints
27
Configuring the Action Mode
27
Setting a Delay
27
Configuring the Trigger Mode for Operating Mode
27
Adjusting the Type of Operating Mode
27
Configuring the PID Loop
28
Setting up the Proportional Gain
28
Setting up the Integral Gain
28
Setting up the Derivative Constant
28
Display Settings
28
Switching on and Adjusting the Brightness of the 360° Safety Halo
28
Adjusting the Screen Brightness
28
Changing the Device Name
28
Home Screen Viewing Modes
29
Diagnostics
30
Viewing the about this HMS Information
30
Accessing the Real-Time View
30
Changing the Setpoints and Deadband from the Real-Time View
30
Adjusting the PID Loop for Analog Output 1 in the Real-Time View
30
Adjusting the PID Loop for Analog Outputs 2, 3, and 4 in the Real-Time View
31
Viewing Digital Inputs in the Real-Time View
31
Viewing Relay Outputs in the Real-Time View
31
Viewing the Alarm Status in the Real-Time View
31
Overriding and Locking Analog Outputs
31
Unlocking the Overridden Analog Output
31
Setting the Actuator to Auto-Stroke
32
Overriding Relay Outputs
32
Saving Settings
32
Restoring Settings
32
Resetting the HMS-2000 Controller and Display
32
Troubleshooting Guide
33
Restricted User Access
34
Setting the Time and Date
34
Adjusting the Alarm Mode
34
Setting the Audible Alarm Delay
35
Changing the Audible Alarm Snooze
35
Switching on and Adjusting the Brightness of the 360° Safety Halo
35
Adjusting the Screen Brightnes
35
Changing the Operating Mode for the Fume Hood
35
Accessing the User Guide Demonstration Video
35
Quick Links
36
Activating and Deactivating the Emergency Purge Mode
36
Adjusting the 360° Safety Halo and Brightness
36
Adjusting the Alarm Mode Quick Link
36
Adjusting the Operating Mode Quick Link
36
Upgrading an Existing HMS-1655 Fume Hood Controller Display
36
Hardware Resource Functionality
37
Technical Specifications
38
Cleaning the Display
39
North American Emissions Compliance
39
Advertisement
Advertisement
Related Products
Johnson Controls HMS1655
Johnson Controls HS3248
Johnson Controls HS2016
Johnson Controls HS2032
Johnson Controls HS2064
Johnson Controls HS2128
Johnson Controls HMH7 Series
Johnson Controls HMH72B24
Johnson Controls HMH72B36
Johnson Controls HMH72B48
Johnson Controls Categories
Controller
Air Conditioner
Thermostat
Control Unit
Irrigation System
More Johnson Controls Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL