Sign In
Upload
Manuals
Brands
ITech Manuals
Network Hardware
IT-M3300 Series
ITech IT-M3300 Series Manuals
Manuals and User Guides for ITech IT-M3300 Series. We have
2
ITech IT-M3300 Series manuals available for free PDF download: User Manual, Programming Manual
ITech IT-M3300 Series Programming Manual (110 pages)
Regenerative DC Electronic Load
Brand:
ITech
| Category:
Measuring Instruments
| Size: 0 MB
Table of Contents
Limitation of Warranty
3
Safety Symbols
3
Warranty
3
Safety Precautions
4
Environmental Conditions
5
Regulatory Markings
5
Waste Electrical and Electronic Equipment (WEEE) Directive
6
Compliance Information
7
Table of Contents
8
Chapter1 SCPI Introduction
13
Overview
13
Command Type of SCPI
13
Message Type of SCPI
15
Response Data Type
17
Command Format
18
Data Type
20
Remote Interface Connections
21
Chapter2 SCPI Status Register
24
Chapter3 Status Commands
24
Status:operation[:Event]
24
Status:operation:condition
24
Status:operation:enable <N
24
Status:operation:ntransition <N
25
Status:operation:ptransition <N
25
Status:questionable[:Event]
26
Status:questionable:condition
26
Status:questionable:enable <N
26
Status:questionable:ntransition <N
27
Status:questionable:ptransition <N
27
Status:preset
28
Chapter4 Channel Selection Commands
29
Channel <NR1
29
Instrument[:Select] <NR1
29
Chapter5 System Commands
31
System:beeper:immediate
31
System:beeper[:State] <Bool
31
System:error
32
System:clear
32
System:remote
33
System:local
33
System:rwlock
33
System:key <N
34
System:communicate:gpib[:Self]:Address <Addr
35
System:communicate:lan:current:address <"Addr
35
System:communicate:lan:current:dgateway <"Addr
36
System:communicate:lan:current:smask <"Addr
36
System:communicate:lan:dhcp <Bool
36
System:communicate:lan:rawsocket:port
37
System:communicate:lan:macaddress
37
System:communicate:serial:baudrate
38
System:version
38
System:communicate:lan:dns1 <Dns
39
System:communicate:lan:dns2 <Dns
39
System:communicate:lan:rawsocketport <Port
39
System:communicate:lan:mdns <Onoff
40
System:communicate:lan:ping <Onoff
40
System:communicate:lan:telnet <Onoff
41
System:communicate:lan:web <Onoff
41
System:communicate:lan:vxi11 <Onoff
42
System:communicate:lan:restore
42
System:communicate:lan:save
42
System:communicate:lan:state
43
System:communicate:lan:hostname
43
System:communicate:lan:description
44
System:communicate:lan:domain
44
[Source:]External[:State] <Bool
44
Address <NR1
45
System:boot:version
45
Chapter6 Measure & Fetch Commands
47
Measure[:Scalar]:Current[:DC]
47
Fetch[:Scalar]:Current[:DC]
47
Measure[:Scalar]:Power[:DC]
47
Fetch[:Scalar]:Power[:DC]
47
Measure[:Scalar]:Voltage[:DC]
48
Fetch[:Scalar]:Voltage[:DC]
48
Measure[:Scalar]:Capacity
48
Fetch[:Scalar]:Capacity
48
Measure[:Scalar]:Uut:temperature
49
Fetch[:Scalar]:Uut:temperature
49
Measure[:Scalar]:Recover:energy
49
Fetch[:Scalar]:Recover:energy
49
Measure[:Scalar]:Local:voltage
50
Fetch[:Scalar]:Local:voltage
50
Measure[:Scalar]:Remote:voltage
50
Fetch[:Scalar]:Remote:voltage
50
Measure[:Scalar]:Ahour
51
Fetch:ahour
51
Measure[:Scalar]:Whour
51
Fetch:whour
51
Measure
51
Fetch
51
Chapter7 Input Commands
53
Input[:State] <Bool
53
[Input:]Protection:clear
53
Input:delay[:Rise] <Nrf
54
Input:delay:fall <Nrf
54
Input:ponsetup <RST|LAST|LOFF
55
Input:short[:State] <BOOLEAN
55
Input:reverse[:State]
56
Input:sds[:State]
56
Input:sds:enable <0|OFF|1|ON
56
Input:sds:DC:relay <0|OFF|1|ON
57
Input:sds:sense:relay <0|OFF|1|ON
57
Input:sds:surge:suppress
58
Input:protection:wdog[:State] <0|OFF|1|ON
58
Input:protection:wdog:delay <Nrf
59
Chapter8 Trigger Commands
60
Trigger[:Immediate]
60
Trigger:list:source <Keypad|Bus
60
Initiate[:Immediate]:List
61
Abort:list
61
Chapter9 Sense Commands
62
Sense[:Remote][:State] <Bool
62
Sense:filter:level <Slow|Medium|Fast
62
Sense:ahour:reset
63
Sense:whour:reset
63
Chapter10 Source Commands
64
[Source:]Current[:Level][:Immediate][:Amplitude] <Nrf
64
[Source:]Current[:Level]:Triggered[:Amplitude] <Nrf
64
[Source:]Current[:Over]:Protection[:Level] <Nrf
65
[Source:]Current[:Over]:Protection:delay <Nrf
65
[Source:]Current[:Over]:Protection:state <Bool
66
[Source:]Current:slew[:Both] <Nrf
66
[Source:]Current:slew:negative <Nrf
67
[Source:]Current:slew:positive <Nrf
67
[Source:]Resistance[:Level][:Immediate][:Amplitude] <Nrf
68
[Source:]Resistance[:Level]:Triggered[:Amplitude] <Nrf
68
[Source:]Voltage[:Level][:Immediate][:Amplitude] <Nrf
69
[Source:]Voltage[:Level]:Triggered[:Amplitude] <Nrf
69
[Source:]Voltage:under:protection[:Level] <Nrf
70
[Source:]Voltage:under:protection:delay <Nrf
70
[Source:]Voltage:under:protection:state <Bool
71
[Source:]Power[:Level][:Immediate][:Amplitude] <Nrf
71
[Source:]Power[:Level]:Triggered[:Amplitude] <Nrf
72
[Source:]Power:protection[:Level] <Nrf
73
[Source:]Power:protection:delay <Nrf
73
[Source:]Power:protection:state <Bool
74
[Source:]Function:mode <Fixed|List|Battery
74
[Source:]Function <Voltage|Current|Power|Resistance|CV+CC|CV+Cr|CC+Cr|CV+CC+Cp+Cr|Bsim
75
[Source:]Voltage:latch[:State] <Bool
75
[Source:]Voltage[:Level]:On <Nrf
76
[Source:]Uut:temperature:protection:state <Bool
76
[Source:]Uut:temperature:protection[:Level] <Nrf
77
Chapter11 Trace Commands
78
Trace:clear
78
Trace:points <Nrf
78
Trace:feed:control <Never|Next|Always
79
Trace:feed[:Selected]<Both|Voltage|Current
79
Trace:delay <Nrf
80
Trace:timer <Nrf
80
Trace:points:actual
81
Trace:clear:auto[:State] <Bool
81
Trace:data
82
Trace:filter[:State]
82
Chapter12 List Commands
83
List:step:count <NR1
83
List[:Step]:Voltage <Nr1>,<Nrf
83
List[:Step]:Current <Nr1>,<Nrf
84
List[:Step]:Power <Nr1>,<Nrf
84
List[:Step]:Resistance <Nr1>,<Nrf
84
LIST[:STEP]:SLEW <Nr1>,<Nrf
85
List[:Step]:Width <Nr1>,<Nrf
85
List:repeat <Nrf
86
List:function <Voltage|Current|Power|Resistance
86
List:save <Nr1
87
List:recall <NR1
87
List[:State] <Bool
88
[Source:]List:terminate:last<Bool
88
List:pause[:State] <BOOLEAN
89
[Source:]List:reset
89
[Source:]List:run:step
90
[Source:]List:run:repeat
90
Chapter13 Battery Commands
91
Battery:discharge:voltage <Nrf
91
Battery:discharge:current <Nrf
91
Battery:stop:voltage <Nrf
92
Battery:stop:current <Nrf
92
Battery:stop:capacity <Nrf
92
Battery:stop:time <Nrf
93
Battery[:State]
93
Battery:save <BANK
94
Battery:recall <BANK
94
[Source:]Battery:reset
95
Chapter14 Parallel&Link Commands
96
Parallel:role <Single|Slave|Master
96
Parallel:group <Group
96
Parallel:number <NR1
97
LINK:MODE <Output|Track
97
Link[:State] <Bool
97
Link:reference <Nrf
98
Chapter15 Common Commands
99
Cls
99
Ese
99
Esr
100
Idn
100
Opc
101
Psc
102
Rcl
102
Rst
103
Sav
103
Sre
104
Stb
104
Trg
105
Tst
105
Wai
106
PSC <Bool
106
Chapter16 Error Messages
108
Error List
108
Advertisement
ITech IT-M3300 Series User Manual (135 pages)
Regenerative DC Electronic Load
Brand:
ITech
| Category:
Network Hardware
| Size: 12 MB
Table of Contents
Warranty
3
Limitation of Warranty
3
Safety Symbols
4
Safety Precautions
4
Environmental Conditions
6
Regulation Tag
7
Waste Electrical and Electronic Equipment (WEEE) Directive
8
Compliance Information
9
Table of Contents
10
1 Quick Reference
12
Brief Introduction
12
Front-Panel Overview
13
Keyboard Introduction
14
Rear Panel Introduction
16
Home-Screen Overview
17
Configuration Menu Reference
18
System Menu Reference
19
Models and Options
23
2 Inspection and Installation
27
Verifying the Shipment
27
Instrument Size Introduction
28
Rack Mounting
28
Connecting the Power Cord
29
Connecting the Device under Test (DUT)
31
Connect the Communication Interface
34
USB Interface
35
GPIB Interface
36
LAN Interface
37
Interface
43
Interface
45
CAN Interface
46
3 Getting Started
49
Power-On the Instrument
49
Set Input Parameters
51
Use the Front Panel Menu
52
Output On/Off Control
53
4 Programming the Input
54
Select the Operation Mode (Mode)
54
Single Operation Mode
55
Complex Operation Mode
56
Battery Simulation Mode
57
Set I-Rise / I-Fall Slope
58
Set the Input-On/Input-Off Delay Time
58
Enable the Input
59
5 Advanced Function
60
LIST Function
60
Battery Discharging Test Function
65
Short-Circuit Analog Function
68
VON Function
68
6 Protection Function
70
Set Over-Current Protection (OCP)
70
Set Over-Power Protection
71
Set Under-Voltage Protection
72
Sense Abnormal Protection Function
73
Over-Temperature Protection
74
7 System-Related Functions
75
Key Lock Function
75
Save and Recall Operations
75
Local/Remote Mode Switch
77
Basic Operation
77
Set the Beeper Status
77
Set the Power-On State
78
Set the Sense Function State
78
Set the Communication Information
78
Select Trigger Source
79
Restore the Factory Default Settings
79
Observe the DUT Temperature and Total Historical Regenerative Power
81
View the System Information
81
Measuring the DUT Temperature
82
UUT Over-Temperature Protection
83
External Analog Function (Optional)
84
8 Multi-Machine Operation
90
Multi-Channel Function
91
Parallel Function (Parallel)
93
Synchronized Function (Link)
96
9 Routine Maintenance
100
Instrument Self-Test
100
Cleaning and Maintenance
100
Information Reference
101
Contact of ITECH Engineers
102
Return for Repair
103
10 Technical Specification
105
M3312
105
M3322
107
M3332
109
M3313
112
M3323
113
M3333
115
M3314
118
M3324
120
M3334
122
M3315
124
M3325
126
M3335
129
11 Supplemental Characteristics
132
A Appendix
133
Specifications of Red and Black Test Cables
133
Advertisement
Related Products
ITech IT-M3312
ITech IT-M3322
ITech IT-M3332
ITech IT-M3313
ITech IT-M3323
ITech IT-M3333
ITech IT-M3314
ITech IT-M3324
ITech IT-M3325
ITech IT-M3335
ITech Categories
Power Supply
Test Equipment
Watch
Measuring Instruments
Racks & Stands
More ITech Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL