Sign In
Upload
Manuals
Brands
Isco Manuals
Measuring Instruments
Signature
Isco Signature Manuals
Manuals and User Guides for Isco Signature. We have
1
Isco Signature manual available for free PDF download: Installation And Operation Manual
Isco Signature Installation And Operation Manual (228 pages)
Flow Meter for TieNet
Brand:
Isco
| Category:
Measuring Instruments
| Size: 26 MB
Table of Contents
Table of Contents
5
Section 1 Introduction
16
Quick Start
16
Compatible Equipment
17
Data Integrity
17
Security
17
Identifying Signature Components
19
Controls and Indicators
20
Keypad
20
Display and LED
21
Backlight and Screen
21
Display Contrast
21
Signature Flow Meter Technical Specifications
21
Technical Specifications
21
Tienet 330 Bubbler Module Technical Specifications
23
Specification Drawing: Signature Flow Meter with Stand in Upward Facing Position
25
Specification Drawing: Signature Bubbler Flow Meter, 1 of 2
26
Specification Drawing: Signature Bubbler Flow Meter, 2 of 2
27
Section 2 Setup and Programming
29
User Interface
29
Keypad Functions
29
Connecting to the Signature with Flowlink
30
Flowlink Connect Screen
31
Site Info Tab
32
Devices Tab
33
Program Tab: Accessing the Browser
34
The Home Screen
35
Shortcuts
35
Adjust Level
35
Adjust Velocity
35
Purge
35
Histograph
35
Real-Time Measurement
36
Report View
36
Programming
36
Off-Screen Content
36
Character Grid
36
Pull down Menus
37
Character Grid
37
Program Steps
38
(Menu Trees)
38
Menu Tree: Top Menu
38
Hardware Setup
39
Smart Sensor Setup (Tienet)
40
Measurement Parameters for each Tienet Device
41
Setup
42
Modbus Input Setup
42
Modbus Setup Worksheet
43
Modbus Input Setup
44
Editing Modbus Device Parameters
45
Modbus Output Setup
46
Modem Setup
46
Configure Options
47
Site Setup
47
Menu Tree: Flow Rate Input Setup
50
Measurement Setup
51
Menu Tree: Volume Input Setup (Total Flow)
51
Adjust
52
Equation/Trigger Setup
52
Data Storage/Push Setup
54
Example of Defining Conditions & Building Equations
54
Inputs/Outputs/Alarms
55
Sampler Setup
55
Setup
55
Local Alarm Setup
56
SMS and Server Alarm Setup (Modem Required)
57
Reports/History Setup
58
Reset Totalizers
58
Administration
58
Display License Information
59
Display Signature Information
59
Language Options
59
Sensor Diagnostics
59
Set New Passcode
59
Update Firmware
59
Gather Fault Data
60
Home
60
Restore to Factory Defaults
60
USB Options
60
Retrieve Data
61
Retrieve Text Reports
61
Update Firmware
61
Gather Fault Data
62
Load Existing Program
62
None of the above
62
Save Current Program
62
Save Signature Information
62
Signature Data in Flowlink
62
Event Viewer
62
Verifying Exported Reports
63
Report File Verifier
64
Section 3 Standard Installation
65
Introduction
65
Connecting External Devices
65
Case Bottom Cable Entries
67
Connector Case, Connectors, and Fuses
67
Connector Case Cable Entries for Power and External Devices
68
Cable Fittings
69
Strain Relief
69
NPT Cord-Grip Fitting for Tienet Devices
69
Cord-Grip Fittings Installed
69
Diameter-Seal Plugs for Unused Ports
70
Connecting Tienet Devices
71
Tienet Device Terminal Strips
71
Tienet Device Terminal Connections
72
Installing Tienet Cable with a Cord-Grip Fitting
72
Attach Wired Terminal Strip to Connector Case Socket
73
Position and Secure the Cable
74
Power
75
Hard Wiring
75
Line Cord
75
Power Connections
75
Mounting the Signature
76
Signature Flow Meter Mounted on Wall
76
Outdoor Recommendations
77
The Bubble Line
78
Standard Bubble Lines
78
Comparing Vinyl and PTFE Bubble Lines
78
Bubble Line Length
78
Attaching the PTFE Bubble Line
79
Attaching the Vinyl Bubble Line
79
Installing the Bubble Line
79
High-Velocity Flow Streams
80
Stilling Wells
81
Flume Bubble Line Fittings
81
Bubble Line Extensions
81
Open Channel Installation
82
Setting the Level
82
Tienet Sensor Installation in a Hazardous Location
83
Hazardous Location Installation Control Drawing-ATEX
84
Section 4 Portable Installation
85
Introduction
85
Portable Stand
85
Adjust Signature to Upward Position
86
Signature Tilted up in Preparation of Removal
87
Power
88
Battery Installation
88
Outdoor Recommendations
88
Power Connections
88
Lead-Acid Battery Installed under the Signature Portable
89
Battery Life Expectancy
90
Major Standard Equipment Settings Effecting Battery Life
90
Additional Considerations for Battery Life
91
Major Optional Equipment Settings Effecting Battery Life
91
Battery Life Expectancy (Default Measurement Rate of 15 Minutes)
91
Battery Life Expectancy
91
Default Method for Portable Signature
92
Calculating Average Current Draw
93
Battery Life Calculations
94
Low Battery Cut off and Battery Care
95
Connect to External Devices
96
Connecting Devices to the Tienet Receptacle
96
How to Connect a Tienet Receptacle to the Signature Portable
97
Removing the Plug
98
Connector Board (R)
99
Section 5 Equipment Options
101
AC Power Cord Kit /AC Wiring (Applies to Permanent Installation Only)
102
Battery Backup (Applies to Permanent Installation Only)
104
Power Loss Alarm
107
Mechanical Totalizer
108
External Desiccator
111
External Desiccator, Installed
111
Tienet ® Devices
112
Ultrasonic Level Sensor
112
Removing the External Desiccant Cartridge
112
Bubbler Level Sensor
113
Laser Doppler Velocity Sensor
113
Continuous Wave Doppler Velocity Sensor
113
Sampler Interface
114
Ph and Temperature Device
115
Tienet Expansion Box
115
Contact Output Card (Tienet 304)
116
Digital Output
120
Analog Input Card (Tienet 307)
121
Analog Output Card (Tienet 308)
125
Isco Flowlink Software
128
Ethernet Modem
128
Ethernet Modem Configuration
131
Network Firewall Settings
132
Cellular Modems
133
CDMA Modem
133
GSM Modem
134
Installing the Cellular Modem
134
FCC ID Label on Modem and Location of Label on the Bottom of Signature Case
135
Cellular Modem Installation
136
Cellular Modem Configuration
137
Cellular Modem Setup: Communication Settings
137
Section 6 Maintenance and Servicing
139
Maintenance
139
Recommended Maintenance (Accessible Locations)
139
Recommended Maintenance (Difficult-To-Access Locations)
139
Cleaning
140
Firmware Updates
140
Accessing the Interior
142
Open Door and Front Panel to Access Interior
142
Backup Battery, Installed
142
Desiccant
143
Internal Desiccator
143
External Desiccator
144
External Desiccator, Installed
144
Removing the External Desiccant Cartridge
145
Troubleshooting
146
Signature Flow Meter
146
Troubleshooting: Signature Flow Meter
146
Tienet 300 Connector Case
149
Tienet 301 Ph/Temp
149
Troubleshooting: Tienet 300 Connector Case
149
Troubleshooting: Tienet 301 Ph/Temperature Device
149
Teinet 304 Contact Output Card
150
Troubleshooting: Tienet 304 Contact Output Card
150
Tienet 307 Analog Input Card
151
Troubleshooting: Tienet 307 Analog Input Card
151
Tienet 306 Sampler Interface
152
Tienet 308 Analog Output
152
Troubleshooting: Tienet 306 Sampler Interface
152
Troubleshooting: Tienet 308 4-20Ma Analog Output
152
Tienet 310 USLS
153
Troubleshooting: Tienet 310 Ultrasonic Level Sensor
153
Tienet 330 Bubbler
154
Plumbing Diagram of Bubbler
155
Troubleshooting: Tienet 330 Bubbler Module
156
Bubbler Installation
157
Preparation: Non-Bubbler
157
Preparation: Existing Bubbler
158
Installation Procedure
159
Bubbler Assembly Installation
159
Front Cover Replacement
162
System Reset
162
Service and Repair
163
Appendix A Replacement Parts
165
How to Order
165
Signature Flow Meter
165
A.2 Signature Flow Meter
166
330 Bubbler
178
Appendix B Options and Accessories
183
Ordering Information
183
Signature Flow Meter Accessories
183
Power Accessories
184
Tienet Accessories
185
Internal to Signature
185
Sensor and Cabling
185
Plug
185
Plug
186
Leads
187
Modems
188
Manuals
188
Sensor Mounting Rings
188
Spring Rings
188
Plug
188
Scissor Rings
189
Appendix C Modbus Output Protocol
191
Introduction
191
Operation
191
Configurations
192
Glossary of Terms
193
Signature ASCII or RTU Address
194
Register Definitions
194
Modbus Registers
194
Appendix D Material Safety Data Sheets
209
Signature Flow Meter
209
Declaration of Conformity
225
Advertisement
Advertisement
Related Products
Isco 4210
ISCO 4230
Isco 674
ISCO Orbit OCM 223
ISCO Orbit OCM 253
Isco Categories
Measuring Instruments
Tools
Refrigerator
Camera Accessories
Lawn and Garden Equipment
More Isco Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL