Sign In
Upload
Manuals
Brands
Immergas Manuals
Boiler
3.033861
Immergas 3.033861 Manuals
Manuals and User Guides for Immergas 3.033861. We have
2
Immergas 3.033861 manuals available for free PDF download: Installation Instructions Manual, Instructions And Warnings
Immergas 3.033861 Installation Instructions Manual (168 pages)
Brand:
Immergas
| Category:
Boiler
| Size: 30 MB
Table of Contents
Table of Contents
2
Dear Customer
5
General Recommendations
6
Safety Symbols Used
7
Personal Protective Equipment
7
Unit Installation
8
Installation Warnings
8
Handling the Appliance
12
Data Nameplate Position
12
Main Dimensions
13
Minimum Installation Distances
14
Position of the Appliances
14
Aeration and Ventilation of the Installation Rooms
15
Antifreeze Protection
17
Other Antifreeze Functions (Optionals)
18
Gas Connection
18
Hydraulic Connection
19
Electrical Connection
20
Commands for Heat Adjustment (Optional)
23
Hydraulic Settings
28
Notes and Tables in Common of Wiring Diagrams
29
Hydraulic Diagram - One Direct Zone - One Mixed Zone - 3-Way Valve - Hydraulic Manifold (One Appliance)
30
Wiring Diagram - One Direct Zone - One Mixed Zone - 3-Way Valve - Hydraulic Manifold (One Appliance)
31
Wiring Diagram - Zone 2 Mixed Heating - 3-Way Valve - Hydraulic Manifold (One Appliance)
32
Wiring Diagram - Zone 2 Mixed Heating- 3-Way Valve - Without Hydraulic Manifold (One Appliance)
33
Wiring Diagram - Two Direct Heating Zones - 3-Way Valve - Hydraulic Manifold (One Appliance)
34
Wiring Diagram - Zone 1 Direct Heating- 3-Way Valve - Hydraulic Manifold (One Appliance)
35
Wiring Diagram - Direct Heating Zone (Without Hydraulic Manifold) - 3-Way Valve - Domestic Hot Water Thermostat (One Appliance)
36
Wiring Diagram - Two Hydraulic Zones with System Heating Pump - 3-Way Valve- Hydraulic Manifold (One Appliance)
37
Wiring Diagram - Two Direct Heating Zones - 3-Way Valve (Without Hydraulic Manifold) (One Appliance)
38
Wiring Diagram - Direct Heating Zone with Booster Pump - 3-Way Valve with Spring Return - External Probe Present (OFF) (One Appliance)
39
Hydraulic Diagram - One Direct Zone - One Mixed Zone - DHW Pump
40
Wiring Diagram - One Direct Zone - One Mixed Zone - DHW Pump - Hydraulic Manifold (One Appliance)
41
Wiring Diagram - Zone 1 Mixed - DHW Pump - Hydraulic Manifold (One Appliance)
42
Wiring Diagram - Two Direct Heating Zones - DHW Pump - Opentherm Thermostats - Hydraulic Manifold (One Appliance)
43
Wiring Diagram - Zone 1 Direct - DHW Pump - Hydraulic Manifold (One Appliance)
44
Wiring Diagram - Zone 1 Direct - DHW Pump - Parallel Operation - Hydraulic Manifold (One Appliance)
45
Wiring Diagram - Two Direct Heating Zones - Dhw Pump - Ch Request Type Constant Setpoint - Hydraulic Manifold (One Appliance)
46
Wiring Diagram - Two Direct Heating Zones - DHW Pump - CH Request Type Only OTC - Hydraulic Manifold (One Appliance)
47
Wiring Diagram - Direct Heating Zone - Booster Pump - Without Hydraulic Manifold (One Appliance)
48
Wiring Diagram with High Power Remote Control
49
Wiring Diagram Connection to BMS System
50
Wiring Diagram BUS-Cascade Connection
51
General Examples of Types of Installation of Flue Systems
52
Immergas Flue Systems
53
Equivalent Lengths of "Green Range" Flue System Components
54
Outdoor Installation
55
Cap Removal for Concentric Kit Installation
57
Concentric Horizontal Kit Installation
57
Concentric Vertical Kit Installation
60
Intake Stub Pipe Kit Installation for Type B Configurations
61
Installation of Vertical Terminals Ø 100
62
Installation of 100 Ø Horizontal Terminals
64
Separator Kit Installation
66
Maximum Flue Length
68
Configuration for C6 Flue Installation
69
Flue Gas Exhaust with Cascade Appliances
70
Water Treatment Plant Filling
70
System Filling
71
Filling the Condensate Drain Trap
71
Operation with System Flow Sensor
71
Simple Cascade
72
Autodetection
73
Anti-Humidity
73
Heating Zones
74
Operation with DHW Storage Tank (Optional)
74
Venting
74
Anti-Legionella
75
Continuous Pump Operation in Heating Mode
75
Gas System Start-Up
75
Appliance Start-Up (Ignition)
76
WILO Circulation Pump
77
Grundfos Circulation Pump
82
Kits Available on Request
84
Main Components
85
Hydraulic Diagram with Optional
87
Installation Examples of Single Appliances
88
Instructions for Use and Maintenance
89
General Recommendations
89
Cleaning and Maintenance
90
Aeration and Ventilation of the Installation Rooms
91
Control Panel
92
Using the Appliance
93
Weekly Schedule
95
Eco
95
Holidays
96
User Menu
97
Fault and Anomaly Signals
106
Appliance Switch-Off
112
Restore Central Heating System Pressure
112
Draining the System
112
Antifreeze Protection
113
Prolonged Inactivity
113
Cleaning the Case
113
Permanent Shutdown
113
Instructions for Maintenance and Initial Check
114
General Recommendations
114
Initial Check
115
Yearly Appliance Check and Maintenance
116
Hydraulic Diagram
118
Wiring Diagram
119
Troubleshooting
123
Technical Menu
124
Programming
143
Converting the Appliance to Other Types of Gas
144
CO Regulation
146
Chimney Sweep
147
Output Adjustment
147
Output Adjustment During DHW (Only in Combination with an Optional External Storage Tank)
147
Pump Antilock, 3-Way Valve and Mixing Valve (Optionals)
147
Antifreeze
148
Gasket Assembly on Manifold
148
Assembling the Manifold on the Condensation Module
149
Replacing the Manifold Insulating Panel
150
Casing Removal
151
Technical Data
154
Variable Heat Output
154
Combustion Parameters
156
Technical Data Table
158
Data Nameplate and Installation Information Sticker Key
159
Technical Parameters for Combination Boilers (in Compliance with Regulation 813/2013)
160
Product Fiche (in Compliance with Regulation 811/2013)
163
Parameters for Filling in the Package Fiche
164
Advertisement
Immergas 3.033861 Instructions And Warnings (60 pages)
CASCADE INSTALLATION
Brand:
Immergas
| Category:
Boiler
| Size: 24 MB
Table of Contents
Table of Contents
2
Installation Recommendations
3
First Start-Up
3
Definition of Cascade
4
Anti-Humidity
5
Installation Clearances Victrix Pro V2 35-55-60-68-80 EU
6
Installation Clearances Victrix Pro V2 100-120 EU
7
Installation Clearances Victrix Pro V2 150 EU
8
Installation Clearance Victrix Pro V2 180 EU
9
Installation of Hydraulic Manifold Kits
10
Installation of Hydraulic Manifold Kit 2 Boilers in Series Victrix Pro V2 35-55-60-68-80 EU
10
Victrix Pro V2 35-55-60-68-80 EU Additional Boiler Hydraulic Manifold Kit Installation
12
Installation of Hydraulic Manifold Kit 2 Boilers in Series Victrix Pro V2 100-120-150 EU
14
Victrix Pro V2 100-120-150 EU Additional Boiler Hydraulic Manifold Kit Installation
16
Installation of Hydraulic Manifold Kit 2 Boilers in Series Victrix Pro V2 180 EU
18
Victrix Pro V2 180 EU Additional Boiler Hydraulic Manifold Kit Installation
20
Flue Installation
22
Installation Recommendations
22
Flue Exhaust Manifold Kit Assembly
22
Assembly of Additional Boiler Manifold Kit for Victrix Pro V2 35-55-60-68-80 EU
23
Assembly of Additional Boiler Manifold Kit for Victrix Pro V2 100-120 EU
24
Assembly of Additional Boiler Manifold Kit for Victrix Pro V2 150 EU
25
Cascade Electrical Connections
26
Simple Cascade
26
Auto-Detection
27
Restore Settings and Parameter Synchronisation
28
Configurable Relays
28
Cascade Technician Menu (Master)
29
Technician Menu (Slave)
30
User Menu (Slave)
34
Installation Diagram Victrix Pro V2 in Simple Cascade Two Direct Heating Zones with DHW Tank
35
Installation Diagram Victrix Pro V2 in Simple Cascade One Direct Central Heating Zone and One Mixed Heating Zone with Domestic Hot Water Boiler
36
Tables and Notes Common to Simple Cascade Wiring Diagrams
37
Wiring Diagram Two Heating Zones (Direct + Mixed) and DHW Pump
38
Wiring Diagram Zone 1 Mixed Heating and DHW Pump
39
Wiring Diagram Two Direct Heating Zones and DHW Pump - Opentherm
40
Wiring Diagram Two Direct Heating Zones and DHW Pump - Only Outdoor Temperature Climate Curve
41
Wiring Diagram Two Direct Heating Zones and DHW Pump - Constant Setpoint
42
Wiring Diagram Direct Heating Zone and DHW Pump
43
Wiring Diagram Direct Heating Zone and DHW Pump - Parallel Operation
44
Wiring Diagram Two Hydraulic Zones with System Heating Pump
45
Simple Cascade Bus Connection Wiring Diagram
46
Wiring Diagram Connection to BMS (Simple Cascade)
47
Cascade and Zone Regulator
48
Cascade Installation Diagram
48
Wiring Diagram with Old Cascade Regulator (3.015244) - Three Heating Zones (Two Mixed and One Direct) with Domestic Hot Water Storage Tank
50
Wiring Diagram with Cascade Regulator and VPV2 Zones (3.034119) - Three Heating Zones (Two Mixed and One Direct) with Domestic Hot Water Storage Tank
51
Wiring Diagram with Cascade Regulator and VPV2 Zones (3.034119) - Five Heating Zones (Four Mixed and One Direct) with Domestic Hot Water Storage Tank
53
Replacing Cascade Generators
55
Replacing Victrix Pro 35-55 2 ERP and Victrix Pro 35-55 1 E with Victrix Pro V2 35-55 EU
56
Replacing Victrix 50 with Victrix Pro V2 55 EU
56
Replacing Victrix 68 2 ERP and Victrix Pro 68 1 E with Victrix Pro V2 68 EU
57
Replacing Victrix 75 with Victrix Pro V2 80 EU
57
Replacing Victrix Pro 80 2 ERP and Victrix Pro 80 1 E with Victrix Pro V2 80 EU
58
Replacing Victrix 90-115 with Victrix Pro V2 100-120 EU
58
Replacing Victrix Pro 100-120 2 ERP and Victrix Pro 100-120 1 E with Victrix Pro V2 100-120 EU
59
Advertisement
Related Products
Immergas 3.033857
Immergas 3.033862
Immergas 3.033860
Immergas 3.033859
Immergas 3.033863
Immergas 3.033858
Immergas 3.033699
Immergas 3.033698
Immergas 3.033701
Immergas 3.033702
Immergas Categories
Boiler
Heat Pump
Boiler Supplies
Water Heater
Air Conditioner
More Immergas Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL